These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 18703686)

  • 21. Closure of patent foramen ovale: technique, pitfalls, complications, and follow up.
    Meier B
    Heart; 2005 Apr; 91(4):444-8. PubMed ID: 15772193
    [No Abstract]   [Full Text] [Related]  

  • 22. Graded balloon dilatation as a prerequisite to Amplatzer device closure of perforated interatrial septal aneurysm.
    Goel PK; Kapoor A
    Singapore Med J; 2012 Jan; 53(1):e18-20. PubMed ID: 22252193
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Device closure of a patent foramen ovale in a patient with lipomatous hypertrophy of the atrial septum.
    Al-Faleh H; Marquis JF; Chan KL
    Can J Cardiol; 2005 Jul; 21(9):789-90. PubMed ID: 16082438
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Three-dimensional transesophageal echocardiography for guiding percutaneous fontan fenestration closure.
    Giannakoulas G; Thanopoulos V
    Echocardiography; 2014 Aug; 31(7):E230-1. PubMed ID: 24697836
    [No Abstract]   [Full Text] [Related]  

  • 25. Thrombus formation on an atrial septal defect closure device.
    Clarke AC; Hirsch KJ; Kells CM; Howlett J
    Can J Cardiol; 2005 Jan; 21(1):68-70. PubMed ID: 15685306
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Completely endoscopic removal of a dislocated Amplatzer atrial septal defect closure device.
    Bonatti J; Bonaros N; Müller S; Bartel T
    Interact Cardiovasc Thorac Surg; 2008 Feb; 7(1):130-2. PubMed ID: 17951273
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [3D-transthoracic echocardiography: a selection method prior to percutaneous closure of atrial septal defects].
    Acar P; Aggoun Y; Le Bret E; Douste-Blazy MY; Abdel-Massih T; Dulac Y; Agnoletti G; Villain E; Bonnet D; Sidi D
    Arch Mal Coeur Vaiss; 2002 May; 95(5):405-10. PubMed ID: 12085737
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects.
    Berger F; Vogel M; Alexi-Meskishvili V; Lange PE
    J Thorac Cardiovasc Surg; 1999 Oct; 118(4):674-8; discussion 678-80. PubMed ID: 10504632
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Percutaneous closure of an atrial septal defect and 3-dimensional echocardiography.
    Mahmood F; Shakil O; Gerstle JR; Matyal R
    J Cardiothorac Vasc Anesth; 2013 Apr; 27(2):400-1. PubMed ID: 23266288
    [No Abstract]   [Full Text] [Related]  

  • 30. Images in cardiovascular medicine. Real-time subcostal 3-dimensional echocardiography for guided percutaneous atrial septal defect closure.
    Roman KS; Nii M; Golding F; Benson LN; Smallhorn JF
    Circulation; 2004 Jun; 109(24):e320-1. PubMed ID: 15210616
    [No Abstract]   [Full Text] [Related]  

  • 31. Pseudo atrial septum defect from a Eustachian valve on transesophageal echocardiogram.
    Akkad I; Wartak S; Moskovits M; Sadiq A; Frankel R; Hollander G; Shani J
    J Echocardiogr; 2017 Mar; 15(1):41-42. PubMed ID: 27423786
    [No Abstract]   [Full Text] [Related]  

  • 32. Real-time 3D transoesophageal echocardiography for guiding Amplatzer septal occluder device deployment in an adult patient with atrial septal defect.
    Acar P; Massabuau P; Elbaz M
    Eur J Echocardiogr; 2008 Nov; 9(6):822-3. PubMed ID: 18579488
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Device closure of fenestrated atrial septal aneurysm: difficulties and complications with implantation of two devices.
    Tchana B; Hagler DJ; Carano N; Agnetti A; Squarcia U
    J Invasive Cardiol; 2004 Sep; 16(9):532-4. PubMed ID: 15353814
    [No Abstract]   [Full Text] [Related]  

  • 34. Intracardiac echocardiography using the AcuNav ultrasound catheter during percutaneous closure of multiple atrial septal defects.
    Ussia GP; Privitera A; Campisi M; Carminati M; De Luca F
    Ital Heart J; 2004 May; 5(5):392-5. PubMed ID: 15185905
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Three-dimensional reconstruction by transesophageal echocardiography of Amplatzer and CardioSEAL prosthetic devices after percutaneous closure and atrial septal defects].
    Acar P; Bonhoeffer P; Saliba Z; Aggoun Y; Bonnet D; Fraisse A; Sidi D; Kachaner J
    Arch Mal Coeur Vaiss; 2000 May; 93(5):539-45. PubMed ID: 10858850
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcatheter closure of secundum atrial septal defects using Amplatzer device.
    Wang G; Chen L; Wang Y; Wen C; Li T; Zhi G; Liu G; Yang T; Gai L
    Chin Med J (Engl); 2000 Nov; 113(11):967-71. PubMed ID: 11776128
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Secundum atrial septal defect resulting in hypoxaemia.
    Iio C; Inoue K; Tashiro R; Higaki T; Higaki J
    Eur Heart J Cardiovasc Imaging; 2014 Jan; 15(1):103. PubMed ID: 23733441
    [No Abstract]   [Full Text] [Related]  

  • 38. Outcomes and alternative techniques for device closure of the large secundum atrial septal defect.
    Varma C; Benson LN; Silversides C; Yip J; Warr MR; Webb G; Siu SC; McLaughlin PR
    Catheter Cardiovasc Interv; 2004 Jan; 61(1):131-9. PubMed ID: 14696173
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Segmental atrial function following percutaneous closure of atrial septum using occluder device.
    Boyd AC; Cooper M; Thomas L
    J Am Soc Echocardiogr; 2009 May; 22(5):508-16. PubMed ID: 19307094
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ostium primum defect with multi-perforated atrial septum.
    Calapkorur B; Koç F; Kaya MG
    Turk Kardiyol Dern Ars; 2009 Oct; 37(7):514. PubMed ID: 20098052
    [No Abstract]   [Full Text] [Related]  