203 related articles for article (PubMed ID: 1870478)
1. Comparison of NaI(Tl), CdTe, and HgI2 surgical probes: physical characterization.
Barber HB; Barrett HH; Hickernell TS; Kwo DP; Woolfenden JM; Entine G; Ortale Baccash C
Med Phys; 1991; 18(3):373-81. PubMed ID: 1870478
[TBL] [Abstract][Full Text] [Related]
2. Comparison of NaI(T1), CdTe, and HgI2 surgical probes: effect of scatter compensation on probe performance.
Kwo DP; Barber HB; Barrett HH; Hickernell TS; Woolfenden JM
Med Phys; 1991; 18(3):382-9. PubMed ID: 1870479
[TBL] [Abstract][Full Text] [Related]
3. Solid state detectors in nuclear medicine.
Darambara DG; Todd-Pokropek A
Q J Nucl Med; 2002 Mar; 46(1):3-7. PubMed ID: 12072840
[TBL] [Abstract][Full Text] [Related]
4. An evaluation of HgI2 detectors for x-ray computed tomography.
Beinglass I; Kaufman L; Hoisier K; Hoenninger J
Med Phys; 1980; 7(4):370-3. PubMed ID: 7393164
[TBL] [Abstract][Full Text] [Related]
5. Comparison of portable CdTe(Cl) detectors with stationary NaI(Tl) detectors for subcutaneous 133Xe disappearance measurements.
Bojsen J; Kølendorf K; Staberg B
Clin Physiol; 1983 Aug; 3(4):325-34. PubMed ID: 6225605
[TBL] [Abstract][Full Text] [Related]
6. [Parameters of detectors for medical x-ray computed tomographs].
Kon'kov VV; Kolesanov AF; Tur'ianskiĭ AG; Tutov EP; Khripunova TA
Med Tekh; 1985; (1):21-5. PubMed ID: 3974429
[TBL] [Abstract][Full Text] [Related]
7. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera.
Russo P; Mettivier G; Pani R; Pellegrini R; Cinti MN; Bennati P
Med Phys; 2009 Apr; 36(4):1298-317. PubMed ID: 19472638
[TBL] [Abstract][Full Text] [Related]
8. Nuclear myocardial perfusion imaging with a cadmium-telluride semiconductor detector gamma camera in patients with acute myocardial infarction.
Fukushima Y; Kumita S; Kawaguchi T; Maruyama T; Kawasaki Y; Shinkai Y
Ann Nucl Med; 2014 Aug; 28(7):646-55. PubMed ID: 24878888
[TBL] [Abstract][Full Text] [Related]
9. Silicon photomultiplier-based scintillation detectors for photon-counting CT: A feasibility study.
van der Sar SJ; Brunner SE; Schaart DR
Med Phys; 2021 Oct; 48(10):6324-6338. PubMed ID: 34169535
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of three gamma detectors for intraoperative detection of tumors using 111In-labeled radiopharmaceuticals.
Benjegård SA; Sauret V; Bernhardt P; Wängberg B; Ahlman H; Forssell-Aronsson E
J Nucl Med; 1999 Dec; 40(12):2094-101. PubMed ID: 10616891
[TBL] [Abstract][Full Text] [Related]
11. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a CdTe semiconductor based compact γ camera for sentinel lymph node imaging.
Russo P; Curion AS; Mettivier G; Esposito M; Aurilio M; Caracò C; Aloj L; Lastoria S
Med Phys; 2011 Mar; 38(3):1547-60. PubMed ID: 21520866
[TBL] [Abstract][Full Text] [Related]
13. The intraoperative gamma probe: basic principles and choices available.
Zanzonico P; Heller S
Semin Nucl Med; 2000 Jan; 30(1):33-48. PubMed ID: 10656242
[TBL] [Abstract][Full Text] [Related]
14. Biotelemetry in local clearance studies with radionuclides using cadmium telluride detectors.
Bojsen J; Staberg B; Kølendorf K
Biotelem Patient Monit; 1982; 9(3):144-53. PubMed ID: 7159700
[TBL] [Abstract][Full Text] [Related]
15. Performance of CdTe, HPGe and NaI(Tl) detectors for radioactivity measurements.
Perez-Andujar A; Pibida L
Appl Radiat Isot; 2004 Jan; 60(1):41-7. PubMed ID: 14687635
[TBL] [Abstract][Full Text] [Related]
16. Bismuth germanate as a potential scintillation detector in positron cameras.
Cho ZH; Farukhi MR
J Nucl Med; 1977 Aug; 18(8):840-4. PubMed ID: 874173
[TBL] [Abstract][Full Text] [Related]
17. Nuclear probes and intraoperative gamma cameras.
Heller S; Zanzonico P
Semin Nucl Med; 2011 May; 41(3):166-81. PubMed ID: 21440694
[TBL] [Abstract][Full Text] [Related]
18. Advanced mercuric iodide detectors for X-ray microanalysis.
Warburton WK; Iwanczyk JS
Scanning Microsc Suppl; 1987; 1():135-50. PubMed ID: 3481104
[TBL] [Abstract][Full Text] [Related]
19. Comparative investigation of the detective quantum efficiency of direct and indirect conversion detector technologies in dedicated breast CT.
Kuttig JD; Steiding C; Kolditz D; Hupfer M; Karolczak M; Kalender WA
Phys Med; 2015 Jun; 31(4):406-13. PubMed ID: 25841299
[TBL] [Abstract][Full Text] [Related]
20. Improved x-ray spectroscopy with room temperature CZT detectors.
Fritz SG; Shikhaliev PM; Matthews KL
Phys Med Biol; 2011 Sep; 56(17):5735-51. PubMed ID: 21841213
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]