These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 1870485)

  • 1. X-ray imaging using amorphous selenium: a photoinduced discharge readout method for digital mammography.
    Rowlands JA; Hunter DM; Araj N
    Med Phys; 1991; 18(3):421-31. PubMed ID: 1870485
    [TBL] [Abstract][Full Text] [Related]  

  • 2. X-ray imaging with amorphous selenium: optimal spectra for digital mammography.
    Fahrig R; Rowlands JA; Yaffe MJ
    Med Phys; 1996 Apr; 23(4):557-67. PubMed ID: 9157270
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.
    Reznik N; Komljenovic PT; Germann S; Rowlands JA
    Med Phys; 2008 Mar; 35(3):1039-50. PubMed ID: 18404939
    [TBL] [Abstract][Full Text] [Related]  

  • 4. X-ray imaging using amorphous selenium: photoinduced discharge (PID) readout for digital general radiography.
    Rowlands JA; Hunter DM
    Med Phys; 1995 Dec; 22(12):1983-96. PubMed ID: 8746703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of a laser scanner for a digital mammography system.
    Rowlands JA; Taylor JE
    Med Phys; 1996 May; 23(5):755-8. PubMed ID: 8724749
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flat-panel digital radiology with amorphous selenium and active-matrix readout.
    Rowlands JA; Zhao W; Blevis IM; Waechter DF; Huang Z
    Radiographics; 1997; 17(3):753-60. PubMed ID: 9153709
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Digital radiology using active matrix readout of amorphous selenium: geometrical and effective fill factors.
    Pang G; Zhao W; Rowlands JA
    Med Phys; 1998 Sep; 25(9):1636-46. PubMed ID: 9775368
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection.
    Zhao W; Law J; Waechter D; Huang Z; Rowlands JA
    Med Phys; 1998 Apr; 25(4):539-49. PubMed ID: 9571622
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
    Zhao C; Kanicki J
    Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
    [TBL] [Abstract][Full Text] [Related]  

  • 10. X-ray imaging with amorphous selenium: theoretical feasibility of the liquid crystal light valve for radiography.
    Rieppo PK; Rowlands JA
    Med Phys; 1997 Aug; 24(8):1279-91. PubMed ID: 9284252
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Image quality of a digital chest radiography system based on a selenium detector.
    Neitzel U; Maack I; Günther-Kohfahl S
    Med Phys; 1994 Apr; 21(4):509-16. PubMed ID: 8058016
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.
    Zhao W; Rowlands JA
    Med Phys; 1997 Dec; 24(12):1819-33. PubMed ID: 9434965
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Physical evaluation of a needle photostimulable phosphor based CR mammography system.
    Marshall NW; Lemmens K; Bosmans H
    Med Phys; 2012 Feb; 39(2):811-24. PubMed ID: 22320791
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector.
    Zhao W; Blevis I; Germann S; Rowlands JA; Waechter D; Huang Z
    Med Phys; 1997 Dec; 24(12):1834-43. PubMed ID: 9434966
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Temporal performance of amorphous selenium mammography detectors.
    Zhao B; Zhao W
    Med Phys; 2005 Jan; 32(1):128-36. PubMed ID: 15719963
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging.
    Hu YH; Zhao W
    Med Phys; 2014 Nov; 41(11):111904. PubMed ID: 25370637
    [TBL] [Abstract][Full Text] [Related]  

  • 17. X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise.
    Hunt DC; Tanioka K; Rowlands JA
    Med Phys; 2007 Mar; 34(3):976-86. PubMed ID: 17441244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.
    Zhao W; Ji WG; Debrie A; Rowlands JA
    Med Phys; 2003 Feb; 30(2):254-63. PubMed ID: 12607843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contact spot xeromammography in the early diagnosis of breast cancer.
    Buchanan JB; Jager RM
    AJR Am J Roentgenol; 1978 Jun; 130(6):1159-62. PubMed ID: 418658
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Can digital selenium-based radiography in thoracic diagnosis replace the analog x-ray imaging technic?].
    Zähringer M; Krug B; Dölken W; Gossmann A; Lackner K
    Rofo; 1997 Jul; 167(1):4-10. PubMed ID: 9289041
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.