These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources. Oliveira ML; Caldas LV Phys Med Biol; 2005 Jun; 50(12):2929-36. PubMed ID: 15930611 [TBL] [Abstract][Full Text] [Related]
7. Dosimetry of beta-ray ophthalmic applicators: comparison of different measurement methods. Soares CG; Vynckier S; Järvinen H; Cross WG; Sipilä P; Flühs D; Schaeken B; Mourtada FA; Bass GA; Williams TT Med Phys; 2001 Jul; 28(7):1373-84. PubMed ID: 11488568 [TBL] [Abstract][Full Text] [Related]
8. Determination of surface dose rate from a 90Sr ophthalmic applicator. Ali MM; Khan FM Med Phys; 1990; 17(3):416-21. PubMed ID: 2385198 [TBL] [Abstract][Full Text] [Related]
9. Measurement of relative output for 90Sr ophthalmic applicators using radiochromic film. Menon G; Sloboda R Med Dosim; 2000; 25(3):171-7. PubMed ID: 11025265 [TBL] [Abstract][Full Text] [Related]
10. Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye. Cross WG; Hokkanen J; Järvinen H; Mourtada F; Sipilä P; Soares CG; Vynckier S Med Phys; 2001 Jul; 28(7):1385-96. PubMed ID: 11488569 [TBL] [Abstract][Full Text] [Related]
12. Calibration of ophthalmic applicators at NIST: a revised approach. Soares CG Med Phys; 1991; 18(4):787-93. PubMed ID: 1921888 [TBL] [Abstract][Full Text] [Related]
13. Comparison of NIST and manufacturer calibrations of 90Sr+90Y ophthalmic applicators. Soares CG Med Phys; 1995 Sep; 22(9):1487-93. PubMed ID: 8531879 [TBL] [Abstract][Full Text] [Related]
14. Regression models for the determination of the absorbed dose rate with an extrapolation chamber for flat ophthalmic applicators. Alvarez Romero JT; Morales Payan JR Health Phys; 1995 Feb; 68(2):234-52. PubMed ID: 7814257 [TBL] [Abstract][Full Text] [Related]
15. Calibration of strontium-90 eye applicator using a strontium external beam standard. Siddle D; Langmack K Phys Med Biol; 1999 Jul; 44(7):1597-608. PubMed ID: 10442699 [TBL] [Abstract][Full Text] [Related]
16. Characteristics of a new polymer gel for high-dose gradient dosimetry using a micro optical CT scanner. Massillon-JL G; Minniti R; Soares CG; Maryanski MJ; Robertson S Appl Radiat Isot; 2010 Jan; 68(1):144-54. PubMed ID: 19775899 [TBL] [Abstract][Full Text] [Related]
17. The determination of dose characteristics of ruthenium ophthalmic applicators using radiochromic film. Taccini G; Cavagnetto F; Coscia G; Garelli S; Pilot A Med Phys; 1997 Dec; 24(12):2034-7. PubMed ID: 9434987 [TBL] [Abstract][Full Text] [Related]
18. Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators. Eichmann M; Flühs D; Spaan B Med Phys; 2009 Oct; 36(10):4634-43. PubMed ID: 19928095 [TBL] [Abstract][Full Text] [Related]
19. Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber. Hakanen AT; Sipilä PM; Kosunen A Med Phys; 2004 May; 31(5):1123-7. PubMed ID: 15191300 [TBL] [Abstract][Full Text] [Related]
20. Ophthalmic applicators: an overview of calibrations following the change to SI units. Holmes SM; Micka JA; DeWerd LA Med Phys; 2009 May; 36(5):1473-7. PubMed ID: 19544762 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]