757 related articles for article (PubMed ID: 18717085)
1. Influence of impression technique and material on the accuracy of multiple implant impressions.
Wöstmann B; Rehmann P; Balkenhol M
Int J Prosthodont; 2008; 21(4):299-301. PubMed ID: 18717085
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of 2 impression techniques for ITI implants.
Akça K; Cehreli MC
Int J Oral Maxillofac Implants; 2004; 19(4):517-23. PubMed ID: 15346748
[TBL] [Abstract][Full Text] [Related]
3. A laboratory investigation of the accuracy of the repositioning impression coping technique at the implant level for single-tooth implants.
Daoudi MF; Setchell DJ; Searson LJ
Eur J Prosthodont Restor Dent; 2003 Mar; 11(1):23-8. PubMed ID: 12705035
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
Vigolo P; Majzoub Z; Cordioli G
J Prosthet Dent; 2003 Feb; 89(2):186-92. PubMed ID: 12616240
[TBL] [Abstract][Full Text] [Related]
5. An evaluation of three implant level impression techniques for single tooth implant.
Daoudi MF; Setchell DJ; Searson LJ
Eur J Prosthodont Restor Dent; 2004 Mar; 12(1):9-14. PubMed ID: 15058176
[TBL] [Abstract][Full Text] [Related]
6. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study.
Lee H; Ercoli C; Funkenbusch PD; Feng C
J Prosthet Dent; 2008 Feb; 99(2):107-13. PubMed ID: 18262011
[TBL] [Abstract][Full Text] [Related]
7. Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.
Sorrentino R; Gherlone EF; Calesini G; Zarone F
Clin Implant Dent Relat Res; 2010 May; 12 Suppl 1():e63-76. PubMed ID: 19438937
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.
Kang AH; Johnson GH; Lepe X; Wataha JC
J Prosthet Dent; 2009 May; 101(5):332-41. PubMed ID: 19410067
[TBL] [Abstract][Full Text] [Related]
9. Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity.
Balkenhol M; Ferger P; Wöstmann B
Int J Prosthodont; 2007; 20(6):573-5. PubMed ID: 18069363
[TBL] [Abstract][Full Text] [Related]
10. Effects of implant system, impression technique, and impression material on accuracy of the working cast.
Wegner K; Weskott K; Zenginel M; Rehmann P; Wöstmann B
Int J Oral Maxillofac Implants; 2013; 28(4):989-95. PubMed ID: 23869356
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of accuracy of multiple dental implant impressions using various splinting materials.
Hariharan R; Shankar C; Rajan M; Baig MR; Azhagarasan NS
Int J Oral Maxillofac Implants; 2010; 25(1):38-44. PubMed ID: 20209185
[TBL] [Abstract][Full Text] [Related]
12. A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.
Daoudi MF; Setchell DJ; Searson LJ
Int J Prosthodont; 2001; 14(2):152-8. PubMed ID: 11843452
[TBL] [Abstract][Full Text] [Related]
13. Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants.
Aguilar ML; Elias A; Vizcarrondo CE; Psoter WJ
J Prosthet Dent; 2010 Apr; 103(4):202-9. PubMed ID: 20362763
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.
Burns J; Palmer R; Howe L; Wilson R
J Prosthet Dent; 2003 Mar; 89(3):250-5. PubMed ID: 12644799
[TBL] [Abstract][Full Text] [Related]
15. The accuracy of an implant impression technique using digitally coded healing abutments.
Eliasson A; Ortorp A
Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e30-8. PubMed ID: 21453396
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the accuracy of plastic and metal stock trays for implant impressions.
Del'acqua MA; de Avila ÉD; Amaral ÂL; Pinelli LA; de Assis Mollo F
Int J Oral Maxillofac Implants; 2012; 27(3):544-50. PubMed ID: 22616047
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection.
Wenz HJ; Hertrampf K
Int J Oral Maxillofac Implants; 2008; 23(1):39-47. PubMed ID: 18416411
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.
Choi JH; Lim YJ; Yim SH; Kim CW
Int J Oral Maxillofac Implants; 2007; 22(5):761-8. PubMed ID: 17974110
[TBL] [Abstract][Full Text] [Related]
19. The dimensional accuracy of four impression techniques with the use of addition silicone impression materials.
Al-Bakri IA; Hussey D; Al-Omari WM
J Clin Dent; 2007; 18(2):29-33. PubMed ID: 17508620
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials.
Liou AD; Nicholls JI; Yuodelis RA; Brudvik JS
Int J Prosthodont; 1993; 6(4):377-83. PubMed ID: 8240649
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]