These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
218 related articles for article (PubMed ID: 18719184)
1. Effect of triclosan on the formation of crystalline biofilms by mixed communities of urinary tract pathogens on urinary catheters. Williams GJ; Stickler DJ J Med Microbiol; 2008 Sep; 57(Pt 9):1135-1140. PubMed ID: 18719184 [TBL] [Abstract][Full Text] [Related]
2. Effect of triclosan on the development of bacterial biofilms by urinary tract pathogens on urinary catheters. Jones GL; Muller CT; O'Reilly M; Stickler DJ J Antimicrob Chemother; 2006 Feb; 57(2):266-72. PubMed ID: 16339844 [TBL] [Abstract][Full Text] [Related]
3. A strategy for the control of catheter blockage by crystalline Proteus mirabilis biofilm using the antibacterial agent triclosan. Jones GL; Russell AD; Caliskan Z; Stickler DJ Eur Urol; 2005 Nov; 48(5):838-45. PubMed ID: 16126323 [TBL] [Abstract][Full Text] [Related]
4. Crystalline bacterial biofilm formation on urinary catheters by urease-producing urinary tract pathogens: a simple method of control. Broomfield RJ; Morgan SD; Khan A; Stickler DJ J Med Microbiol; 2009 Oct; 58(Pt 10):1367-1375. PubMed ID: 19556373 [TBL] [Abstract][Full Text] [Related]
5. Species interactions in mixed-community crystalline biofilms on urinary catheters. Macleod SM; Stickler DJ J Med Microbiol; 2007 Nov; 56(Pt 11):1549-1557. PubMed ID: 17965358 [TBL] [Abstract][Full Text] [Related]
6. Reduced Susceptibility of Proteus mirabilis to triclosan. Stickler DJ; Jones GL Antimicrob Agents Chemother; 2008 Mar; 52(3):991-4. PubMed ID: 18180352 [TBL] [Abstract][Full Text] [Related]
7. Some observations on the diffusion of antimicrobial agents through the retention balloons of foley catheters. Williams GJ; Stickler DJ J Urol; 2007 Aug; 178(2):697-701. PubMed ID: 17574612 [TBL] [Abstract][Full Text] [Related]
8. Antimicrobial activity Study of triclosan-loaded WBPU on Proteus mirabilis in vitro. Tian Y; Jian Z; Wang J; He W; Liu Q; Wang K; Li H; Tan H Int Urol Nephrol; 2017 Apr; 49(4):563-571. PubMed ID: 28150092 [TBL] [Abstract][Full Text] [Related]
9. Studies on the formation of crystalline bacterial biofilms on urethral catheters. Stickler D; Morris N; Moreno MC; Sabbuba N Eur J Clin Microbiol Infect Dis; 1998 Sep; 17(9):649-52. PubMed ID: 9832268 [TBL] [Abstract][Full Text] [Related]
10. [An improved model of a catheterised human bladder for screening bactericidal agents]. Schulz A; Vestweber AM; Leis W; Stark D; Dressler D Aktuelle Urol; 2008 Jan; 39(1):53-7. PubMed ID: 18228188 [TBL] [Abstract][Full Text] [Related]
11. Control of encrustation and blockage of Foley catheters. Stickler DJ; Jones GL; Russell AD Lancet; 2003 Apr; 361(9367):1435-7. PubMed ID: 12727400 [TBL] [Abstract][Full Text] [Related]
12. Clinical complications of urinary catheters caused by crystalline biofilms: something needs to be done. Stickler DJ J Intern Med; 2014 Aug; 276(2):120-9. PubMed ID: 24635559 [TBL] [Abstract][Full Text] [Related]
13. Does drinking cranberry juice produce urine inhibitory to the development of crystalline, catheter-blocking Proteus mirabilis biofilms? Morris NS; Stickler DJ BJU Int; 2001 Aug; 88(3):192-7. PubMed ID: 11488728 [TBL] [Abstract][Full Text] [Related]
14. Observations on the development of the crystalline bacterial biofilms that encrust and block Foley catheters. Stickler DJ; Morgan SD J Hosp Infect; 2008 Aug; 69(4):350-60. PubMed ID: 18550219 [TBL] [Abstract][Full Text] [Related]
16. A clinical assessment of the performance of a sensor to detect crystalline biofilm formation on indwelling bladder catheters. Stickler DJ; Jones SM; Adusei GO; Waters MG; Cloete J; Mathur S; Feneley RC BJU Int; 2006 Dec; 98(6):1244-9. PubMed ID: 17026594 [TBL] [Abstract][Full Text] [Related]
17. Does the valve regulated release of urine from the bladder decrease encrustation and blockage of indwelling catheters by crystalline proteus mirabilis biofilms? Sabbuba NA; Stickler DJ; Long MJ; Dong Z; Short TD; Feneley RJ J Urol; 2005 Jan; 173(1):262-6. PubMed ID: 15592093 [TBL] [Abstract][Full Text] [Related]
18. Some observations on the migration of Proteus mirabilis and other urinary tract pathogens over foley catheters. Williams GJ; Stickler DJ Infect Control Hosp Epidemiol; 2008 May; 29(5):443-5. PubMed ID: 18419368 [TBL] [Abstract][Full Text] [Related]
19. Encrustation of indwelling urethral catheters by Proteus mirabilis biofilms growing in human urine. Morris NS; Stickler DJ J Hosp Infect; 1998 Jul; 39(3):227-34. PubMed ID: 9699143 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of Antimicrobial Durability and Anti-Biofilm Effects in Urinary Catheters Against Kart D; Kustimur AS; Sağıroğlu M; Kalkancı A Balkan Med J; 2017 Dec; 34(6):546-552. PubMed ID: 29215338 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]