BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 18724810)

  • 1. Determination of serum creatinine by Jaffe method and how to calibrate to eliminate matrix interference problems.
    Chromý V; Rozkosná K; Sedlák P
    Clin Chem Lab Med; 2008; 46(8):1127-33. PubMed ID: 18724810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
    Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
    Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.
    Nah H; Lee SG; Lee KS; Won JH; Kim HO; Kim JH
    Clin Biochem; 2016 Feb; 49(3):274-81. PubMed ID: 26519089
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method.
    Fillée C; Vranken G; Othmane M; Philippe M; Allaeys JM; Courbe A; Ruelle JL; Peeters R
    Clin Chem Lab Med; 2011 Dec; 49(12):1987-99. PubMed ID: 21801031
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiway calibration for creatinine determination in human serum using the Jaffé reaction.
    Guterres MV; Volpe PO; Ferreira MM
    Appl Spectrosc; 2004 Jan; 58(1):54-60. PubMed ID: 14727721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enzymatic assays for creatinine: time for action.
    Panteghini M;
    Clin Chem Lab Med; 2008; 46(4):567-72. PubMed ID: 18298343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of standardized calibration on the inter-assay variation of 14 automated assays for the measurement of creatinine in human serum.
    Séronie-Vivien S; Galteau MM; Carlier MC; Hadj-Aissa A; Hanser AM; Hym B; Marchal A; Michotey O; Pouteil-Noble C; Sternberg M; Perret-Liaudet A;
    Clin Chem Lab Med; 2005; 43(11):1227-33. PubMed ID: 16232080
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Serum creatinine determined by Jaffe, enzymatic method, and isotope dilution-liquid chromatography-mass spectrometry in patients under hemodialysis.
    Liu WS; Chung YT; Yang CY; Lin CC; Tsai KH; Yang WC; Chen TW; Lai YT; Li SY; Liu TY
    J Clin Lab Anal; 2012 May; 26(3):206-14. PubMed ID: 22628238
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles.
    Greenberg N; Roberts WL; Bachmann LM; Wright EC; Dalton RN; Zakowski JJ; Miller WG
    Clin Chem; 2012 Feb; 58(2):391-401. PubMed ID: 22166253
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Serum ultrafiltration for the elimination of endogenous interfering substances in creatinine determination.
    da Fonseca-Wollheim F; Heinze KG; Lomsky K; Schreiner H
    J Clin Chem Clin Biochem; 1988 Aug; 26(8):523-5. PubMed ID: 3221182
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.
    Delanghe JR; Cobbaert C; Galteau MM; Harmoinen A; Jansen R; Kruse R; Laitinen P; Thienpont LM; Wuyts B; Weykamp C; Panteghini M
    Clin Chem Lab Med; 2008; 46(9):1319-25. PubMed ID: 18605952
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Is the assessment of serum creatinine reliable?].
    Kotaska K; Jedlicková B; Průsa R
    Cas Lek Cesk; 2008; 147(7):392-5. PubMed ID: 18678099
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Does the ID-MS traceable MDRD equation work and is it suitable for use with compensated Jaffe and enzymatic creatinine assays?
    Vickery S; Stevens PE; Dalton RN; van Lente F; Lamb EJ
    Nephrol Dial Transplant; 2006 Sep; 21(9):2439-45. PubMed ID: 16720592
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of an isotope dilution GC-MS procedure for the routine determination of creatinine in complex serum samples.
    Fernández-Fernández M; González-Antuña A; Rodríguez-González P; Añón Álvarez ME; Álvarez FV; García Alonso JI
    Clin Chim Acta; 2014 Apr; 431():96-102. PubMed ID: 24508629
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffé method.
    Junge W; Wilke B; Halabi A; Klein G
    Clin Chim Acta; 2004 Jun; 344(1-2):137-48. PubMed ID: 15149882
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation and comparison of Abbott Jaffe and enzymatic creatinine methods: Could the old method meet the new requirements?
    Küme T; Sağlam B; Ergon C; Sisman AR
    J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28205269
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enzymatic assays for creatinine: time for action.
    Panteghini M
    Scand J Clin Lab Invest Suppl; 2008; 241():84-8. PubMed ID: 18569972
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.
    Lindbäck B; Bergman A
    Clin Chem; 1989 May; 35(5):835-7. PubMed ID: 2541950
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Applicability of common reference intervals for serum creatinine concentrations to the Croatian population.
    Flegar-Mestrić Z; Perkov S; Simonović B; Juretić D
    Clin Chem Lab Med; 2010 Feb; 48(2):231-5. PubMed ID: 19943808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Improving the interlaboratory variation for creatinine serum assay].
    Séronie-Vivien S; Galteau MM; Carlier MC; Hadj-Aissa A; Hanser AM; Hym B; Marchal A; Michotey O; Pouteil-Noble C; Sternberg M; Perret-Liaudet A;
    Ann Biol Clin (Paris); 2004; 62(2):165-75. PubMed ID: 15047468
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.