These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

579 related articles for article (PubMed ID: 18725188)

  • 1. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces.
    Huber M; Reinisch G; Trettenhahn G; Zweymüller K; Lintner F
    Acta Biomater; 2009 Jan; 5(1):172-80. PubMed ID: 18725188
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Low-Carbon Metal-on-Metal Articulations for Hip Arthroplasties--Evaluation of Wear and Histology after 11 to 17 Years].
    Reinisch G; Huber M; Zweymüller KA
    Z Orthop Unfall; 2015 Aug; 153(4):392-8. PubMed ID: 25993351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Local and distant products from modularity.
    Jacobs JJ; Urban RM; Gilbert JL; Skipor AK; Black J; Jasty M; Galante JO
    Clin Orthop Relat Res; 1995 Oct; (319):94-105. PubMed ID: 7554654
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements.
    Lee SH; Brennan FR; Jacobs JJ; Urban RM; Ragasa DR; Glant TT
    J Orthop Res; 1997 Jan; 15(1):40-9. PubMed ID: 9066525
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal contents and associated histologic findings.
    Betts F; Wright T; Salvati EA; Boskey A; Bansal M
    Clin Orthop Relat Res; 1992 Mar; (276):75-82. PubMed ID: 1537178
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings.
    Savarino L; Granchi D; Ciapetti G; Cenni E; Nardi Pantoli A; Rotini R; Veronesi CA; Baldini N; Giunti A
    J Biomed Mater Res; 2002; 63(5):467-74. PubMed ID: 12209889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [New metod for quantification of UHMWPE wear particles around joint replacements].
    Pokorný D; Slouf M; Dybal J; Zolotarevová E; Veselý F; Jahoda D; Vavrík P; Landor I; Entlicher G; Sosna A
    Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):374-81. PubMed ID: 19912700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Method for assessment of distribution of UHMWPE wear particles in periprosthetic tissues in total hip arthroplasty].
    Pokorný D; Slouf M; Horák Z; Jahoda D; Entlicher G; Eklová S; Sosna A
    Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):243-50. PubMed ID: 17026883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hard bearing surfaces in total hip arthroplasty.
    Jazrawi LM; Kummer FJ; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1998 Apr; 27(4):283-92. PubMed ID: 9586727
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements.
    Zolotarevova E; Entlicher G; Pavlova E; Slouf M; Pokorny D; Vesely F; Gallo J; Sosna A
    Acta Biomater; 2010 Sep; 6(9):3595-600. PubMed ID: 20417318
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bearing surfaces for total disc arthroplasty: metal-on-metal versus metal-on-polyethylene and other biomaterials.
    Golish SR; Anderson PA
    Spine J; 2012 Aug; 12(8):693-701. PubMed ID: 21700505
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers.
    Wimmer MA; Fischer A; Büscher R; Pourzal R; Sprecher C; Hauert R; Jacobs JJ
    J Orthop Res; 2010 Apr; 28(4):436-43. PubMed ID: 19877285
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Osteolysis in patients with a metal-on-metal hip arthroplasty.
    Carr AM; DeSteiger R
    ANZ J Surg; 2008 Mar; 78(3):144-7. PubMed ID: 18269476
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo corrosion of cobalt-chromium and titanium wear particles.
    Shahgaldi BF; Heatley FW; Dewar A; Corrin B
    J Bone Joint Surg Br; 1995 Nov; 77(6):962-6. PubMed ID: 7593115
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transfer of metallic debris after dislocation of ceramic femoral heads in hip prostheses.
    Müller FA; Hagymási M; Greil P; Zeiler G; Schuh A
    Arch Orthop Trauma Surg; 2006 Apr; 126(3):174-80. PubMed ID: 16482451
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Activation of periprosthetic connective tissue in aseptic loosening of total hip replacements.
    Santavirta S; Xu JW; Hietanen J; Ceponis A; Sorsa T; Kontio R; Konttinen YT
    Clin Orthop Relat Res; 1998 Jul; (352):16-24. PubMed ID: 9678029
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal on metal bearings. A practical alternative to metal on polyethylene total joints?
    Black J
    Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S244-55. PubMed ID: 8769338
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biologic activity of wear particles.
    Catelas I; Jacobs JJ
    Instr Course Lect; 2010; 59():3-16. PubMed ID: 20415362
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Catastrophic wear in a metal-on-ceramic total hip arthroplasty.
    Valentí JR; Del Río J; Amillo S
    J Arthroplasty; 2007 Sep; 22(6):920-2. PubMed ID: 17826286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.