BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 18725662)

  • 1. Mini-incision dynamic condylar screw fixation for comminuted subtrochanteric hip fractures.
    Rohilla R; Singh R; Magu NK; Siwach RC; Sangwan SS
    J Orthop Surg (Hong Kong); 2008 Aug; 16(2):150-5. PubMed ID: 18725662
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Indirect reduction and biological internal fixation of comminuted subtrochanteric fractures of the femur.
    Celebi L; Can M; Muratli HH; Yagmurlu MF; Yuksel HY; Bicimoğlu A
    Injury; 2006 Aug; 37(8):740-50. PubMed ID: 16487528
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biological fixation of comminuted subtrochanteric fractures with proximal femur locking compression plate.
    Saini P; Kumar R; Shekhawat V; Joshi N; Bansal M; Kumar S
    Injury; 2013 Feb; 44(2):226-31. PubMed ID: 23200761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biological plate fixation of comminuted subtrochanteric fractures with the Dynamic Condylar Screw: a clinical study.
    Neogi DS; Trikha V; Mishra KK; Rohilla N; Yadav CS
    Acta Orthop Belg; 2009 Aug; 75(4):497-503. PubMed ID: 19774817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Treatment of comminuted subtrochanteric fractures by dynamic hip screw.
    Ali M
    J Pak Med Assoc; 1995 Aug; 45(8):212-5. PubMed ID: 8775491
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical outcome of conventional versus biological fixation of subtrochanteric fractures by proximal femoral locked plate.
    El-Desouky II; Mohamed MM; Kandil AE
    Injury; 2016 Jun; 47(6):1309-17. PubMed ID: 27015752
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Treatment of Seinsheimer type V subtrochanteric femoral fractures with dynamic hip screw and shape memory alloy bow-teeth screw].
    Liu XW; Wang PF; Fu QG; Zhang CC; Xu SG; Su JC; Pan SH
    Zhongguo Gu Shang; 2010 Apr; 23(4):288-90. PubMed ID: 20486383
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biological plate osteosynthesis of comminuted subtrochanteric fractures: a clinical study.
    Mehrpour SR; Aghamirsalim M; Tavvafi M; Sorbi R
    Hip Int; 2012; 22(3):324-8. PubMed ID: 22740270
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bridge-plating osteosynthesis of 20 comminuted subtrochanteric fractures with dynamic hip screw.
    Lee PC; Yu SW; Hsieh PH; Su JY; Chen YJ
    Chang Gung Med J; 2002 Dec; 25(12):803-10. PubMed ID: 12635836
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures.
    Oh CW; Kim JJ; Byun YS; Oh JK; Kim JW; Kim SY; Park BC; Lee HJ
    Arch Orthop Trauma Surg; 2009 Dec; 129(12):1659-65. PubMed ID: 19169695
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures.
    Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S
    Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminut- ed fractures of femoral neck].
    Hou WR; Xu MO
    Zhongguo Gu Shang; 2015 Sep; 28(9):796-801. PubMed ID: 26647559
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures.
    Gupta S; Kukreja S; Singh V
    J Orthop Surg (Hong Kong); 2014 Apr; 22(1):13-7. PubMed ID: 24781606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The dynamic hip screw for the management of per- and subtrochanteric femoral fractures].
    Kwasny O; Fuchs M
    Unfallchirurg; 1991 Aug; 94(8):430-5. PubMed ID: 1925622
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Treatment of Seinsheimer type V subtrochanteric femoral fractures with inversive LISS plate combined with steel wire].
    Song XZ; Chen W; Zheng J
    Zhongguo Gu Shang; 2014 Aug; 27(8):697-9. PubMed ID: 25464600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The role of biological fixation with bridge plating for comminuted subtrochanteric fractures of the femur.
    Kayali C; Ağuş H; Zincircioğlu G
    Ulus Travma Acil Cerrahi Derg; 2008 Jan; 14(1):53-8. PubMed ID: 18306068
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment of subtrochanteric fractures of the femur: reduction on the traction table and fixation with dynamic condylar screw.
    Blatter G; Janssen M
    Arch Orthop Trauma Surg; 1994; 113(3):138-41. PubMed ID: 8054234
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A newly designed locked intramedullary nail for trochanteric hip fractures fixation: results of the first 100 Trochanteric implantations.
    Loubignac F; Chabas JF
    Orthop Traumatol Surg Res; 2009 Apr; 95(2):139-44. PubMed ID: 19345659
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biologic plating versus intramedullary nailing for comminuted subtrochanteric fractures in young adults: a prospective, randomized study of 66 cases.
    Lee PC; Hsieh PH; Yu SW; Shiao CW; Kao HK; Wu CC
    J Trauma; 2007 Dec; 63(6):1283-91. PubMed ID: 18212651
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fixation using cannulated screws and fibular strut grafts for fresh femoral neck fractures with posterior comminution.
    Zahid M; Bin Sabir A; Asif N; Julfiqar M; Khan AQ; Ahmad S; Siddiqui YS
    J Orthop Surg (Hong Kong); 2012 Aug; 20(2):191-5. PubMed ID: 22933677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.