These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
12. Endovascular revascularization of renal artery stenosis in the solitary functioning kidney. Davies MG; Saad WE; Bismuth JX; Naoum JJ; Peden EK; Lumsden AB J Vasc Surg; 2009 Apr; 49(4):953-60. PubMed ID: 19217744 [TBL] [Abstract][Full Text] [Related]
13. A study on the outcome of percutaneous transluminal renal angioplasty in patients with renal failure. Roussos L; Christensson A; Thompson O Nephron Clin Pract; 2006; 104(3):c132-42. PubMed ID: 16899992 [TBL] [Abstract][Full Text] [Related]
14. Renal artery stenting slows the rate of renal function decline. Arthurs Z; Starnes B; Cuadrado D; Sohn V; Cushner H; Andersen C J Vasc Surg; 2007 Apr; 45(4):726-31; discussion 731-2. PubMed ID: 17398382 [TBL] [Abstract][Full Text] [Related]
15. Percutaneous transluminal renal angioplasty with stent is effective for blood pressure control and renal function improvement in atherosclerotic renal artery stenosis patients. Liao CJ; Yang BZ; Wang ZG Chin Med J (Engl); 2012 Apr; 125(8):1363-8. PubMed ID: 22613636 [TBL] [Abstract][Full Text] [Related]
17. Long-term renal function preservation after renal artery stenting in patients with progressive ischemic nephropathy. Rocha-Singh KJ; Ahuja RK; Sung CH; Rutherford J Catheter Cardiovasc Interv; 2002 Oct; 57(2):135-41. PubMed ID: 12357507 [TBL] [Abstract][Full Text] [Related]
18. Nine-month results of the REFORM study: a prospective, single-arm, multicenter clinical study of the safety and effectiveness of the Formula™ balloon-expandable stent for treatment of renal artery stenosis. Bersin RM; Ansel G; Rizzo A; Bob Smouse H; Sinha S; Sachar R; Dave R; Weinstock BS; Feldman R; Roubin GS Catheter Cardiovasc Interv; 2013 Aug; 82(2):266-73. PubMed ID: 22581488 [TBL] [Abstract][Full Text] [Related]
19. Percutaneous renal artery intervention versus medical therapy in patients with renal artery stenosis: a meta-analysis. Shetty R; Biondi-Zoccai GG; Abbate A; Amin MS; Jovin IS EuroIntervention; 2011 Nov; 7(7):844-51. PubMed ID: 22082580 [TBL] [Abstract][Full Text] [Related]
20. Objective performance goals of safety and blood pressure efficacy for clinical trials of renal artery bare metal stents in hypertensive patients with atherosclerotic renal artery stenosis. Rocha-Singh KJ; Novack V; Pencina M; D'Agostino R; Ansel G; Rosenfield K; Jaff MR Catheter Cardiovasc Interv; 2011 Nov; 78(5):779-89. PubMed ID: 21648052 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]