These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 1874048)

  • 1. [Bilateral arm amputation caused by high voltage burns in childhood: stump reconstruction by tissue expansion and fibula transfer].
    Steinau HU; Askenazy L; Biemer E; Gradinger J
    Chirurg; 1991 May; 62(5):426-9. PubMed ID: 1874048
    [No Abstract]   [Full Text] [Related]  

  • 2. Parascapular fasciocutaneous flap for covering an above-elbow amputation stump.
    Kumar P; Chandra R; Bhatnagar SK; Bhagia SP
    Burns; 1991 Oct; 17(5):425-6. PubMed ID: 1760117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Maintenance of stump length of both upper extremities after severe electrical burn injury.
    Kömürcü F; Stuffer M; Hussl H; Anderl H
    Burns; 1990 Jun; 16(3):227-9. PubMed ID: 2383367
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reconstruction of transhumeral amputation stumps with ipsilateral pedicled latissimus dorsi myocutaneous flap in high voltage electrical burns.
    Kesiktas E; Eser C; Gencel E; Aslaner EE; Yavuz M
    Burns; 2015 Mar; 41(2):401-7. PubMed ID: 25440851
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Free skin autoplasty of the amputated stump].
    Batkin AA; Krylov KM
    Vestn Khir Im I I Grek; 1966 Dec; 97(12):71-3. PubMed ID: 4949568
    [No Abstract]   [Full Text] [Related]  

  • 6. Salvage of a below-elbow amputation stump with a free latissimus dorsi muscle flap: a case report.
    Jones ML; Blair WF
    J Hand Surg Am; 1994 Mar; 19(2):207-8. PubMed ID: 8201182
    [No Abstract]   [Full Text] [Related]  

  • 7. [Amputation and prosthesis after electric trauma of the upper limbs].
    Sarkisov MA; Regentov SA
    Vestn Khir Im I I Grek; 1974 Nov; 113(11):103-5. PubMed ID: 4439590
    [No Abstract]   [Full Text] [Related]  

  • 8. [Electric burns of the upper limbs caused by high-voltage current].
    Della Santa D; Hoffmeyer P
    Helv Chir Acta; 1986 Apr; 52(6):881-4. PubMed ID: 3710817
    [No Abstract]   [Full Text] [Related]  

  • 9. Prosthetic rehabilitation in bilateral high above elbow amputation.
    Johansen PB; Breitholtz M; Cavrini R; Johansson B; Schmidl H; Thyberg M
    Scand J Rehabil Med; 1987; 19(2):85-7. PubMed ID: 3616527
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The quadrifoliate flap: a combination of scapular, parascapular, latissimus dorsi and scapula bone flaps.
    Bakhach J; Peres JM; Scalise A; Martin D; Baudet J
    Br J Plast Surg; 1996 Oct; 49(7):477-81. PubMed ID: 8983553
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Immediate functional reconstruction of the upper extremity after high voltage electric burns].
    Herndl E; Henckel von Donnersmarck G; Hupfer W; Mühlbauer W
    Langenbecks Arch Chir Suppl II Verh Dtsch Ges Chir; 1989; ():853-8. PubMed ID: 2577651
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Free bone plasty for lengthening of short arm stumps.
    Godunov SF; Keier AN
    Acta Chir Plast; 1969; 11(2):163-74. PubMed ID: 4184617
    [No Abstract]   [Full Text] [Related]  

  • 13. Prosthetic use in patients with burns and associated limb amputations.
    Ward RS; Hayes-Lundy C; Schnebly WA; Saffle JR
    J Burn Care Rehabil; 1990; 11(4):361-4. PubMed ID: 2401693
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Musculocutaneous flaps for increased load capacity of the above-elbow stump].
    Martini AK
    Handchir Mikrochir Plast Chir; 1983 Mar; 15(1):43-6. PubMed ID: 6852675
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Electrical burns of the upper limbs].
    Tuma Júnior P; de Faria JC; Fontana C; Goldenberg DC; Ferreira MC
    Rev Hosp Clin Fac Med Sao Paulo; 1995; 50 Suppl():13-6. PubMed ID: 7659921
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Microsurgical reconstruction of the burned upper extremity].
    Ofer N; Baumeister S; Ohlbauer M; Germann G; Sauerbier M
    Handchir Mikrochir Plast Chir; 2005 Aug; 37(4):245-55. PubMed ID: 16149033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Case report: occupational therapy with a traumatic bilateral shoulder disarticulation amputee.
    Garza P
    Am J Occup Ther; 1986 Mar; 40(3):194-8. PubMed ID: 3963130
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Penile and upper extremity amputation following high-voltage electrical trauma: case report.
    Landecker A; Macieira L
    Burns; 2002 Dec; 28(8):806-10. PubMed ID: 12464483
    [No Abstract]   [Full Text] [Related]  

  • 19. Early surgery in severe electrical burns involving upper limbs.
    Wang XW; Wei JN; Lu JZ; Wang NZ; Lu CS; Yin DQ; Jia SL
    Chin Med J (Engl); 1982 Oct; 95(10):717-20. PubMed ID: 6817974
    [No Abstract]   [Full Text] [Related]  

  • 20. [Secondary reconstruction of stumps above the elbow. Five cases].
    Schoofs M; Leps P; Houzé de l'Aulnoit S; Auvray G
    Ann Chir Plast Esthet; 2001 Apr; 46(2):95-102. PubMed ID: 11340942
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]