653 related articles for article (PubMed ID: 18752068)
1. Online digital filter and QRS detector applicable in low resource ECG monitoring systems.
Tabakov S; Iliev I; Krasteva V
Ann Biomed Eng; 2008 Nov; 36(11):1805-15. PubMed ID: 18752068
[TBL] [Abstract][Full Text] [Related]
2. Meet the challenge of high-pass filter and ST-segment requirements with a DC-coupled digital electrocardiogram amplifier.
Abächerli R; Schmid HJ
J Electrocardiol; 2009; 42(6):574-9. PubMed ID: 19700169
[TBL] [Abstract][Full Text] [Related]
3. Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators.
Jekova I; Krasteva V
Physiol Meas; 2005 Dec; 26(6):987-1003. PubMed ID: 16311447
[TBL] [Abstract][Full Text] [Related]
4. A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV.
Ruha A; Sallinen S; Nissilä S
IEEE Trans Biomed Eng; 1997 Mar; 44(3):159-67. PubMed ID: 9216129
[TBL] [Abstract][Full Text] [Related]
5. Real-time detection of pathological cardiac events in the electrocardiogram.
Iliev I; Krasteva V; Tabakov S
Physiol Meas; 2007 Mar; 28(3):259-76. PubMed ID: 17322591
[TBL] [Abstract][Full Text] [Related]
6. What is inside the electrocardiograph?
Gregg RE; Zhou SH; Lindauer JM; Helfenbein ED; Giuliano KK
J Electrocardiol; 2008; 41(1):8-14. PubMed ID: 18191652
[TBL] [Abstract][Full Text] [Related]
7. The morphological classification of heartbeats as dominant and non-dominant in ECG signals.
Chiarugi F; Emmanouilidou D; Tsamardinos I
Physiol Meas; 2010 May; 31(5):611-31. PubMed ID: 20308771
[TBL] [Abstract][Full Text] [Related]
8. Heart beat detection using a multimodal data coupling method.
Mollakazemi MJ; Atyabi SA; Ghaffari A
Physiol Meas; 2015 Aug; 36(8):1729-42. PubMed ID: 26218667
[TBL] [Abstract][Full Text] [Related]
9. Effects of electrocardiograph frequency filters on P-QRS-T amplitudes of the feline electrocardiogram.
Schrope DP; Fox PR; Hahn AW; Bond B; Rosenthal S
Am J Vet Res; 1995 Nov; 56(11):1534-40. PubMed ID: 8585669
[TBL] [Abstract][Full Text] [Related]
10. QRS detection based on wavelet coefficients.
Zidelmal Z; Amirou A; Adnane M; Belouchrani A
Comput Methods Programs Biomed; 2012 Sep; 107(3):490-6. PubMed ID: 22296976
[TBL] [Abstract][Full Text] [Related]
11. Real-time 12-lead high-frequency QRS electrocardiography for enhanced detection of myocardial ischemia and coronary artery disease.
Schlegel TT; Kulecz WB; DePalma JL; Feiveson AH; Wilson JS; Rahman MA; Bungo MW
Mayo Clin Proc; 2004 Mar; 79(3):339-50. PubMed ID: 15008608
[TBL] [Abstract][Full Text] [Related]
12. A statistical approach for determination of time plane features from digitized ECG.
Chatterjee HK; Gupta R; Mitra M
Comput Biol Med; 2011 May; 41(5):278-84. PubMed ID: 21458786
[TBL] [Abstract][Full Text] [Related]
13. Validation testing of the spacelabs PC2 ST-segment analyzer.
London MJ; Ahlstrom LD
J Cardiothorac Vasc Anesth; 1995 Dec; 9(6):684-93. PubMed ID: 8664460
[TBL] [Abstract][Full Text] [Related]
14. Threshold-based system for noise detection in multilead ECG recordings.
Jekova I; Krasteva V; Christov I; Abächerli R
Physiol Meas; 2012 Sep; 33(9):1463-77. PubMed ID: 22902891
[TBL] [Abstract][Full Text] [Related]
15. Genetic design of optimum linear and nonlinear QRS detectors.
Poli R; Cagnoni S; Valli G
IEEE Trans Biomed Eng; 1995 Nov; 42(11):1137-41. PubMed ID: 7498919
[TBL] [Abstract][Full Text] [Related]
16. The effect of 50/60 Hz notch filter application on human and rat ECG recordings.
Vale-Cardoso AS; Guimarães HN
Physiol Meas; 2010 Jan; 31(1):45-58. PubMed ID: 19940344
[TBL] [Abstract][Full Text] [Related]
17. High-resolution electrocardiography.
Berbari EJ
Crit Rev Biomed Eng; 1988; 16(1):67-103. PubMed ID: 3293914
[TBL] [Abstract][Full Text] [Related]
18. Real-time electrocardiogram P-QRS-T detection-delineation algorithm based on quality-supported analysis of characteristic templates.
Karimipour A; Homaeinezhad MR
Comput Biol Med; 2014 Sep; 52():153-65. PubMed ID: 25063881
[TBL] [Abstract][Full Text] [Related]
19. [Beat-by-beat validation of the Oxford Medilog 4500, a 24-hour long-term ECG system with real-time analysis].
Elfner R; Buss J; Kraatz J; Heene DL
Z Kardiol; 1987 Aug; 76(8):492-500. PubMed ID: 2445117
[TBL] [Abstract][Full Text] [Related]
20. Single-lead fetal electrocardiogram estimation by means of combining R-peak detection, resampling and comb filter.
Zheng W; Liu H; He A; Ning X; Cheng J
Med Eng Phys; 2010 Sep; 32(7):708-19. PubMed ID: 20466579
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]