317 related articles for article (PubMed ID: 18756356)
1. Three-dimensional SPECT reconstruction with transmission-dependent scatter correction.
Sohlberg A; Watabe H; Iida H
Ann Nucl Med; 2008 Aug; 22(7):549-56. PubMed ID: 18756356
[TBL] [Abstract][Full Text] [Related]
2. Correction for scatter and septal penetration using convolution subtraction methods and model-based compensation in 123I brain SPECT imaging-a Monte Carlo study.
Larsson A; Ljungberg M; Mo SJ; Riklund K; Johansson L
Phys Med Biol; 2006 Nov; 51(22):5753-67. PubMed ID: 17068363
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of 3D Monte Carlo-based scatter correction for 201Tl cardiac perfusion SPECT.
Xiao J; de Wit TC; Zbijewski W; Staelens SG; Beekman FJ
J Nucl Med; 2007 Apr; 48(4):637-44. PubMed ID: 17401103
[TBL] [Abstract][Full Text] [Related]
4. Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities.
Kim KM; Varrone A; Watabe H; Shidahara M; Fujita M; Innis RB; Iida H
J Nucl Med; 2003 Apr; 44(4):512-9. PubMed ID: 12679393
[TBL] [Abstract][Full Text] [Related]
5. Absolute quantification in dopaminergic neurotransmission SPECT using a Monte Carlo-based scatter correction and fully 3-dimensional reconstruction.
Cot A; Falcón C; Crespo C; Sempau J; Pareto D; Bullich S; Lomeña F; Calviño F; Pavía J; Ros D
J Nucl Med; 2005 Sep; 46(9):1497-504. PubMed ID: 16157533
[TBL] [Abstract][Full Text] [Related]
6. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT.
Xiao J; de Wit TC; Staelens SG; Beekman FJ
J Nucl Med; 2006 Oct; 47(10):1662-9. PubMed ID: 17015903
[TBL] [Abstract][Full Text] [Related]
8. Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction.
Bexelius T; Sohlberg A
Ann Nucl Med; 2018 Jun; 32(5):337-347. PubMed ID: 29564718
[TBL] [Abstract][Full Text] [Related]
9. Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.
Beekman FJ; de Jong HW; van Geloven S
IEEE Trans Med Imaging; 2002 Aug; 21(8):867-77. PubMed ID: 12472260
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study.
Yokoi T; Shinohara H; Onishi H
Ann Nucl Med; 2002 Feb; 16(1):11-8. PubMed ID: 11922203
[TBL] [Abstract][Full Text] [Related]
11. Implementation of an iterative scatter correction, the influence of attenuation map quality and their effect on absolute quantitation in SPECT.
Vandervoort E; Celler A; Harrop R
Phys Med Biol; 2007 Mar; 52(5):1527-45. PubMed ID: 17301469
[TBL] [Abstract][Full Text] [Related]
12. Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction.
Zeintl J; Vija AH; Yahil A; Hornegger J; Kuwert T
J Nucl Med; 2010 Jun; 51(6):921-8. PubMed ID: 20484423
[TBL] [Abstract][Full Text] [Related]
13. Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging.
Ouyang J; El Fakhri G; Moore SC
Med Phys; 2007 Aug; 34(8):3263-72. PubMed ID: 17879789
[TBL] [Abstract][Full Text] [Related]
14. Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction.
Kangasmaa TS; Kuikka JT; Vanninen EJ; Mussalo HM; Laitinen TP; Sohlberg AO
Nucl Med Commun; 2011 Nov; 32(11):1040-5. PubMed ID: 21956490
[TBL] [Abstract][Full Text] [Related]
15. Monte Carlo-based down-scatter correction of SPECT attenuation maps.
Bokulić T; Vastenhouw B; de Jong HW; van Dongen AJ; van Rijk PP; Beekman FJ
Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1173-81. PubMed ID: 15034678
[TBL] [Abstract][Full Text] [Related]
16. Acceleration of Monte Carlo-based scatter compensation for cardiac SPECT.
Sohlberg A; Watabe H; Iida H
Phys Med Biol; 2008 Jul; 53(14):N277-85. PubMed ID: 18574315
[TBL] [Abstract][Full Text] [Related]
17. Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.
Niu X; Yang Y; Jin M; Wernick MN; King MA
Med Phys; 2011 Dec; 38(12):6571-84. PubMed ID: 22149839
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation.
Kangasmaa TS; Constable C; Sohlberg AO
Nucl Med Commun; 2018 Dec; 39(12):1097-1102. PubMed ID: 30222722
[TBL] [Abstract][Full Text] [Related]
19. Hybrid scatter correction applied to quantitative holmium-166 SPECT.
de Wit TC; Xiao J; Nijsen JF; van het Schip FD; Staelens SG; van Rijk PP; Beekman FJ
Phys Med Biol; 2006 Oct; 51(19):4773-87. PubMed ID: 16985270
[TBL] [Abstract][Full Text] [Related]
20. Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.
El Fakhri G; Buvat I; Benali H; Todd-Pokropek A; Di Paola R
J Nucl Med; 2000 Aug; 41(8):1400-8. PubMed ID: 10945534
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]