155 related articles for article (PubMed ID: 18759607)
1. Magnetic field interactions in adjustable hydrocephalus shunts.
Lavinio A; Harding S; Van Der Boogaard F; Czosnyka M; Smielewski P; Richards HK; Pickard JD; Czosnyka ZH
J Neurosurg Pediatr; 2008 Sep; 2(3):222-8. PubMed ID: 18759607
[TBL] [Abstract][Full Text] [Related]
2. Effect of transcranial magnetic stimulation on four types of pressure-programmable valves.
Lefranc M; Ko JY; Peltier J; Fichten A; Desenclos C; Macron JM; Toussaint P; Le Gars D; Petitjean M
Acta Neurochir (Wien); 2010 Apr; 152(4):689-97. PubMed ID: 19957091
[TBL] [Abstract][Full Text] [Related]
3. [Effect of magnetic fields from home-use magnetic induction therapy apparatuses on adjustable cerebrospinal fluid shunt valves].
Nakashima K; Oishi A; Itokawa H; Fujimoto M
No Shinkei Geka; 2010 Aug; 38(8):725-9. PubMed ID: 20697146
[TBL] [Abstract][Full Text] [Related]
4. Transcutaneous pressure-adjustable valves and magnetic resonance imaging: an ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve.
Ortler M; Kostron H; Felber S
Neurosurgery; 1997 May; 40(5):1050-7; discussion 1057-8. PubMed ID: 9149264
[TBL] [Abstract][Full Text] [Related]
5. Effect of 3-tesla magnetic resonance imaging on various pressure programmable shunt valves.
Inoue T; Kuzu Y; Ogasawara K; Ogawa A
J Neurosurg; 2005 Aug; 103(2 Suppl):163-5. PubMed ID: 16370283
[TBL] [Abstract][Full Text] [Related]
6. Programmable shunt valves: in vitro assessment of safety of the magnetic field generated by a portable game machine.
Nakashima K; Nakajo T; Kawamo M; Kato A; Ishigaki S; Murakami H; Imaizumi Y; Izumiyama H
Neurol Med Chir (Tokyo); 2011; 51(9):635-8. PubMed ID: 21946726
[TBL] [Abstract][Full Text] [Related]
7. Programmable shunt valve interactions with osseointegrated hearing devices.
J Neurosurg Pediatr; 2017 Apr; 19(4):384-390. PubMed ID: 28186475
[TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of shunt implantations using Sophy programmable pressure valves: comparison with Codman-Hakim programmable valves.
Katano H; Karasawa K; Sugiyama N; Yamashita N; Ohkura A; Kamiya K
J Clin Neurosci; 2003 Sep; 10(5):557-61. PubMed ID: 12948459
[TBL] [Abstract][Full Text] [Related]
9. Programmable shunts and headphones: Are they safe together?
Spader HS; Ratanaprasatporn L; Morrison JF; Grossberg JA; Cosgrove GR
J Neurosurg Pediatr; 2015 Oct; 16(4):402-5. PubMed ID: 26149436
[TBL] [Abstract][Full Text] [Related]
10. Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study.
Chen B; Dammann P; Jabbarli R; Sure U; Quick HH; Kraff O; Wrede KH
PLoS One; 2023; 18(10):e0292666. PubMed ID: 37819939
[TBL] [Abstract][Full Text] [Related]
11. Unexpectedly Smaller Artifacts of 3.0-T Magnetic Resonance Imaging than 1.5 T: Recommendation of 3.0-T Scanners for Patients with Magnet-Resistant Adjustable Ventriculoperitoneal Shunt Devices.
Amano Y; Kuroda N; Uchida D; Sakakura Y; Nakatogawa H; Ando N; Nakayama T; Sato H; Masui T; Sameshima T; Tanaka T
World Neurosurg; 2019 Oct; 130():e393-e399. PubMed ID: 31260847
[TBL] [Abstract][Full Text] [Related]
12. Laboratory testing of hydrocephalus shunts -- conclusion of the U.K. Shunt evaluation programme.
Czosnyka Z; Czosnyka M; Richards HK; Pickard JD
Acta Neurochir (Wien); 2002 Jun; 144(6):525-38; discussion 538. PubMed ID: 12111485
[TBL] [Abstract][Full Text] [Related]
13. Magnetic toys: forbidden for pediatric patients with certain programmable shunt valves?
Zuzak TJ; Balmer B; Schmidig D; Boltshauser E; Grotzer MA
Childs Nerv Syst; 2009 Feb; 25(2):161-4. PubMed ID: 19057906
[TBL] [Abstract][Full Text] [Related]
14. Interactions between programmable shunt valves and the iPad 3 with Smart Cover.
He Y; Murphy RK; Roland JL; Limbrick DD
Childs Nerv Syst; 2013 Apr; 29(4):531-3. PubMed ID: 23423659
[TBL] [Abstract][Full Text] [Related]
15. Electromagnetic field hazards involving adjustable shunt valves in hydrocephalus.
Schneider T; Knauff U; Nitsch J; Firsching R
J Neurosurg; 2002 Feb; 96(2):331-4. PubMed ID: 11838808
[TBL] [Abstract][Full Text] [Related]
16. In vitro performance of six combinations of adjustable differential pressure valves and fixed anti-siphon devices with and without vertical motion.
Fiss I; Röhrig P; Hore N; von der Brelie C; Bettag C; Freimann FB; Thomale UW; Rohde V; Brandner S
Acta Neurochir (Wien); 2020 Oct; 162(10):2421-2430. PubMed ID: 32779025
[TBL] [Abstract][Full Text] [Related]
17. Interactions between programmable shunt valves and magnetically controlled growing rods for scoliosis.
Larrew T; Alshareef M; Murphy RF; Eskandari R; Kosnik Infinger L
J Neurosurg Pediatr; 2020 Oct; 26(6):667-670. PubMed ID: 33007746
[TBL] [Abstract][Full Text] [Related]
18. Setting pressure can change the size and shape of MRI artifacts caused by adjustable shunt valves: a study of the 4 newest models.
Uchida D; Amano Y; Nakatogawa H; Masui T; Ando N; Nakayama T; Sato H; Sameshima T; Tanaka T
J Neurosurg; 2018 May; 130(4):1260-1267. PubMed ID: 29775146
[TBL] [Abstract][Full Text] [Related]
19. Effect of exposure from iPhone 12 on programmable ventriculoperitoneal shunts.
Kumar A; Pervaiz A; Borg A; Abdul-Hamid A; Jeyaretna S; MacKeith S; Qureishi A
Br J Neurosurg; 2022 Jun; 36(3):415-419. PubMed ID: 35062838
[TBL] [Abstract][Full Text] [Related]
20. Hydrodynamic properties of hydrocephalus shunts.
Czosnyka Z; Czosnyka M; Richards H; Pickard JD
Acta Neurochir Suppl; 1998; 71():334-9. PubMed ID: 9779223
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]