BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 18761255)

  • 1. Re: Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope.
    Manickam BP; Adhikary SD
    J Clin Anesth; 2008 Aug; 20(5):401-402. PubMed ID: 18761255
    [No Abstract]   [Full Text] [Related]  

  • 2. An Unanticipated Airway Finding After Orotracheal Intubation With a GlideScope Videolaryngoscope.
    Pagel PS; Chapel MA; Georgeson AR; Traudt EA; Little RE; Loehrl TA; Somberg LB
    J Cardiothorac Vasc Anesth; 2019 Mar; 33(3):873-875. PubMed ID: 30213637
    [No Abstract]   [Full Text] [Related]  

  • 3. Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope.
    Vincent RD; Wimberly MP; Brockwell RC; Magnuson JS
    J Clin Anesth; 2007 Dec; 19(8):619-21. PubMed ID: 18083477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Traumatic GlideScope(®) video laryngoscopy resulting in perforation of the soft palate.
    Amundson AW; Weingarten TN
    Can J Anaesth; 2013 Feb; 60(2):210-1. PubMed ID: 23180060
    [No Abstract]   [Full Text] [Related]  

  • 5. Perforation of the soft palate using the GlideScope videolaryngoscope.
    Cross P; Cytryn J; Cheng KK
    Can J Anaesth; 2007 Jul; 54(7):588-9. PubMed ID: 17602049
    [No Abstract]   [Full Text] [Related]  

  • 6. [Videolaryngoscopy for endotracheal intubation - new developments in difficult airway management].
    Wasem S; Roewer N; Lange M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2009 Jul; 44(7-8):502-8. PubMed ID: 19629911
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Soft Palate Injuries During Orotracheal Intubation With the Videolaryngoscope.
    Pham Q; Lentner M; Hu A
    Ann Otol Rhinol Laryngol; 2017 Feb; 126(2):132-137. PubMed ID: 27831515
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Soft palate trauma induced during GlideScope intubation.
    Allencherril JP; Joseph L
    J Clin Anesth; 2016 Dec; 35():278-280. PubMed ID: 27871543
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of the GlideScope in paediatric foreign body upper airway obstruction.
    Warner L; Daudia A
    Br J Anaesth; 2014 Jun; 112(6):1119-20. PubMed ID: 24829425
    [No Abstract]   [Full Text] [Related]  

  • 10. A simple method for preventing the fog in the videolaryngoscope monitor during awake intubation.
    Haba M; Komasawa N
    J Clin Anesth; 2018 Feb; 44():84-85. PubMed ID: 29161545
    [No Abstract]   [Full Text] [Related]  

  • 11. Maneuvers to prevent oropharyngeal injury during orotracheal intubation with the GlideScope video laryngoscope.
    Dupanovic M
    J Clin Anesth; 2010 Mar; 22(2):152-4. PubMed ID: 20304363
    [No Abstract]   [Full Text] [Related]  

  • 12. A maneuver to facilitate endotracheal intubation using the GlideScope.
    Cho JE; Kil HK
    Can J Anaesth; 2008 Jan; 55(1):56-7. PubMed ID: 18166752
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of a single-use GlideScope Cobalt videolaryngoscope with a conventional GlideScope for orotracheal intubation.
    Jones PM; Turkstra TP; Armstrong KP; Armstrong PM; Harle CC
    Can J Anaesth; 2010 Jan; 57(1):18-23. PubMed ID: 19882199
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the McGrath Series 5 videolaryngoscope after failed direct laryngoscopy.
    Noppens RR; Möbus S; Heid F; Schmidtmann I; Werner C; Piepho T
    Anaesthesia; 2010 Jul; 65(7):716-20. PubMed ID: 20528841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Video laryngoscopy for ICU intubation: a meta-analysis of randomised trials.
    Zhao BC; Huang TY; Liu KX
    Intensive Care Med; 2017 Jun; 43(6):947-948. PubMed ID: 28260161
    [No Abstract]   [Full Text] [Related]  

  • 16. A randomized comparison of the GlideScope videolaryngoscope to the standard laryngoscopy for intubation by pediatric residents in simulated easy and difficult infant airway scenarios.
    Fonte M; Oulego-Erroz I; Nadkarni L; Sánchez-Santos L; Iglesias-Vásquez A; Rodríguez-Núñez A
    Pediatr Emerg Care; 2011 May; 27(5):398-402. PubMed ID: 21494161
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions.
    Aziz MF; Healy D; Kheterpal S; Fu RF; Dillman D; Brambrink AM
    Anesthesiology; 2011 Jan; 114(1):34-41. PubMed ID: 21150569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope.
    Turkstra TP; Jones PM; Ower KM; Gros ML
    Anesth Analg; 2009 Dec; 109(6):1856-9. PubMed ID: 19923515
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Report of 2 Cases of Oropharyngeal Injury With the Use of Video Laryngoscopy Techniques.
    Huffman B; Puri S; Heyman H; Kumar V; Kao S
    J Oral Maxillofac Surg; 2016 Oct; 74(10):1948.e1-5. PubMed ID: 27186872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tracheal intubation with the AirwayScope videolaryngoscope using straight vs curved reinforced tubes.
    Minonishi T; Kinoshita H; Tange K; Hatakeyama N; Matsuda N; Azma T; Hatano Y
    Can J Anaesth; 2010 Jan; 57(1):92-3. PubMed ID: 19866244
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 13.