BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

877 related articles for article (PubMed ID: 18762030)

  • 1. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
    Guda T; Ross TA; Lang LA; Millwater HR
    J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant abutment screw rotations and preloads for four different screw materials and surfaces.
    Martin WC; Woody RD; Miller BH; Miller AW
    J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis to determine implant preload.
    Lang LA; Kang B; Wang RF; Lang BR
    J Prosthet Dent; 2003 Dec; 90(6):539-46. PubMed ID: 14668754
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implant-abutment screw joint preload of 7 hex-top abutment systems.
    Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2001; 16(3):367-77. PubMed ID: 11432656
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant.
    Jörn D; Kohorst P; Besdo S; Rücker M; Stiesch M; Borchers L
    J Prosthet Dent; 2014 Aug; 112(2):340-8. PubMed ID: 24529658
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method.
    Bulaqi HA; Mousavi Mashhadi M; Geramipanah F; Safari H; Paknejad M
    J Prosthet Dent; 2015 May; 113(5):405-11. PubMed ID: 25749081
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic nature of abutment screw retightening: finite element study of the effect of retightening on the settling effect.
    Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
    J Prosthet Dent; 2015 May; 113(5):412-9. PubMed ID: 25749092
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Elongation and preload stress in dental implant abutment screws.
    Haack JE; Sakaguchi RL; Sun T; Coffey JP
    Int J Oral Maxillofac Implants; 1995; 10(5):529-36. PubMed ID: 7590997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Operator-induced compressive axial forces during implant gold screw fastening.
    Pesun IJ; Brosky ME; Korioth TW; Hodges J; Devoe BJ
    J Prosthet Dent; 2001 Jul; 86(1):15-9. PubMed ID: 11458259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
    Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
    Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of abutment screw preload on stress distribution in marginal bone.
    Khraisat A
    Int J Oral Maxillofac Implants; 2012; 27(2):303-7. PubMed ID: 22442768
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Probabilistic analysis of peri-implant strain predictions as influenced by uncertainties in bone properties and occlusal forces.
    Petrie CS; Williams JL
    Clin Oral Implants Res; 2007 Oct; 18(5):611-9. PubMed ID: 17590159
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of repeated torque in small diameter implants with machined and premachined abutments.
    Saboury A; Neshandar Asli H; Vaziri S
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e224-30. PubMed ID: 22376004
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of abutment screw coating on implant preload.
    Park JK; Choi JU; Jeon YC; Choi KS; Jeong CM
    J Prosthodont; 2010 Aug; 19(6):458-64. PubMed ID: 20456024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of preload values in gold and titanium dental implant retaining screws.
    Doolabh R; Dullabh HD; Sykes LM
    SADJ; 2014 Aug; 69(7):316-20. PubMed ID: 26548212
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Examination of the implant-abutment interface after fatigue testing.
    Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA
    J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.