These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 18774683)

  • 41. [Prostheto-prosthetic and aorto-prosthetic anastomosis using stents, threads, clips and staples. In vitro comparative study].
    Garitey V; Rieu R; Alimi YS
    J Mal Vasc; 2003 Oct; 28(4):173-7. PubMed ID: 14618105
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Experimental study of poly-L-lactic acid biodegradable stents in normal canine bile ducts.
    Yamamoto K; Yoshioka T; Furuichi K; Sakaguchi H; Anai H; Tanaka T; Morimoto K; Uchida H; Kichikawa K
    Cardiovasc Intervent Radiol; 2011 Jun; 34(3):601-8. PubMed ID: 21153415
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Evaluation of an absorbable ring for vascular anastomosis.
    Kimura H; Muneshige H; Ikuta Y
    J Reconstr Microsurg; 1999 Jul; 15(5):331-6. PubMed ID: 10445512
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [The study of the biodegradable biliary duct stent in vivo].
    Fan C; Zhai C; Lu Y; Zhu H; Tan M; Yu L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Aug; 28(4):763-7. PubMed ID: 21936377
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Laparoscopic colonic anastomosis using a degradable stent in a porcine model.
    Ma L; Cai XJ; Wang HH; Yu YL; Huang DY; Ge GJ; Hu HY; Yu SC
    World J Gastroenterol; 2016 May; 22(19):4707-15. PubMed ID: 27217702
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Drug-eluting biodegradable poly-D/L-lactic acid vascular stents: an experimental pilot study.
    Uurto I; Mikkonen J; Parkkinen J; Keski-Nisula L; Nevalainen T; Kellomäki M; Törmälä P; Salenius JP
    J Endovasc Ther; 2005 Jun; 12(3):371-9. PubMed ID: 15943514
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Experimental study of aortic anastomosis using a circular stapling device in the porcine model.
    Yoshida K; Ohtake H; Kimura K; Watanabe G
    Eur J Vasc Endovasc Surg; 2006 Jun; 31(6):575-80. PubMed ID: 16464620
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Sutureless microvascular anastomosis with the aid of heparin loaded poloxamer 407.
    Özer F; Nişancı M; Taş Ç; Rajadas J; Alhan D; Bozkurt Y; Günal A; Demirtaş S; Işık S
    J Plast Reconstr Aesthet Surg; 2017 Feb; 70(2):267-273. PubMed ID: 27939908
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A novel technique for hepaticojejunostomy for nondilated bile ducts: a purse-string anastomosis with an intra-anastomotic biodegradable biliary stent.
    Laukkarinen J; Sand J; Leppiniemi J; Kellomäki M; Nordback I
    Am J Surg; 2010 Jul; 200(1):124-30. PubMed ID: 20074696
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A systematic review of sutureless vascular anastomosis technologies.
    Mallela DP; Bose S; Shallal CC; Goldsborough E; Xun H; Chen J; Stonko DP; Brandacher G; Sacks J; Kang SH; Hicks CW
    Semin Vasc Surg; 2021 Dec; 34(4):247-259. PubMed ID: 34911631
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Tissue-engineered stent-graft integrates with aortic wall by recruiting host tissue into graft scaffold.
    Takeuchi M; Kuratani T; Miyagawa S; Shirakawa Y; Shimamura K; Kin K; Yoshida T; Arai Y; Hoashi T; Teramoto N; Hirakawa K; Kawaguchi N; Sawa Y
    J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1719-25. PubMed ID: 25260279
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Application of a new type of sutureless magnetic biliary-enteric anastomosis stent for one-stage reconstruction of the biliary-enteric continuity after acute bile duct injury: an experimental study.
    Li J; Lü Y; Qu B; Zhang Z; Liu C; Shi Y; Wang B
    J Surg Res; 2008 Aug; 148(2):136-42. PubMed ID: 18511078
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Bioabsorbable device for small-caliber vessel anastomosis.
    Ueda K; Mukai T; Ichinose S; Koyama Y; Takakuda K
    Microsurgery; 2010 Sep; 30(6):494-501. PubMed ID: 20238380
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Monitoring in vivo absorption of a drug-eluting bioabsorbable stent with intravascular ultrasound-derived parameters a feasibility study.
    Bruining N; de Winter S; Roelandt JR; Regar E; Heller I; van Domburg RT; Hamers R; Onuma Y; Dudek D; Webster MW; Thuesen L; Ormiston JA; Cheong WF; Miquel-Hebert K; Veldhof S; Serruys PW
    JACC Cardiovasc Interv; 2010 Apr; 3(4):449-56. PubMed ID: 20398874
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of the deployment and healing of thin-walled expanded PTFE stented grafts and covered stents.
    White R; Kopchok G; Zalewski M; Ayres B; Wilson E; de Virgilio C; Donayre C
    Ann Vasc Surg; 1996 Jul; 10(4):336-46. PubMed ID: 8879388
    [TBL] [Abstract][Full Text] [Related]  

  • 56. An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude Medical stainless steel connector.
    Schaff HV; Zehr KJ; Bonilla LF; Brennecke LH; Berg T; Cornelius R; Hindrichs P; Swanson W
    Ann Thorac Surg; 2002 Mar; 73(3):830-5; discussion 835-6. PubMed ID: 11899187
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis.
    Liu H; Zhang SJ; Shao YF; Lu XH; Gu WD; Ni BQ; Gu Q; Du JJ
    J Biomed Res; 2018 Nov; 32(5):454-460. PubMed ID: 28963444
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Gastrojejunal anastomosis using a tissue-apposing stent: a safety and feasibility study in live pigs.
    Vanbiervliet G; Bonin EA; Garcès R; Gonzalez JM; Garnier E; Paul MC; Berdah S; Barthet M
    Endoscopy; 2014 Oct; 46(10):871-7. PubMed ID: 25019971
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Serial late dilatations of expanded polytetrafluoroethylene-covered stents in porcine aorta.
    Gordon BM; Fishbein MC; Levi DS
    Catheter Cardiovasc Interv; 2008 Sep; 72(3):400-407. PubMed ID: 18727120
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Study of biodegradable and self-expandable PLLA helical biliary stent in vivo and in vitro.
    Meng B; Wang J; Zhu N; Meng QY; Cui FZ; Xu YX
    J Mater Sci Mater Med; 2006 Jul; 17(7):611-7. PubMed ID: 16770545
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.