These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 18781282)

  • 1. Role of transjugular liver biopsy in the diagnostic and therapeutic management of patients with severe liver disease.
    Esposito AA; Nicolini A; Meregaglia D; Sangiovanni A; Biondetti P
    Radiol Med; 2008 Oct; 113(7):1008-17. PubMed ID: 18781282
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transjugular liver biopsy: assessment of safety and efficacy of the Quick-Core biopsy needle.
    Bruzzi JF; O'Connell MJ; Thakore H; O'Keane C; Crowe J; Murray JG
    Abdom Imaging; 2002; 27(6):711-5. PubMed ID: 12395261
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transjugular liver biopsy with an automated device.
    Kardache M; Soyer P; Boudiaf M; Cochand-Priollet B; Pelage JP; Rymer R
    Radiology; 1997 Aug; 204(2):369-72. PubMed ID: 9240522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transjugular liver biopsy: histological diagnosis success comparing the trucut to the modified aspiration Ross needle.
    Maciel AC; Marchiori E; de Barros SG; Cerski CT; Tarasconi DP; Ilha Dde O
    Arq Gastroenterol; 2003; 40(2):80-4. PubMed ID: 14762476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the diagnostic quality of aspiration and core-biopsy needles for transjugular liver biopsy.
    Stift J; Semmler G; Wöran K; Simbrunner B; Scheiner B; Schwabl P; Paternostro R; Pinter M; Stättermayer AF; Meischl T; Beer A; Trauner M; Mandorfer M; Reiberger T
    Dig Liver Dis; 2020 Dec; 52(12):1473-1479. PubMed ID: 32928675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transjugular liver biopsy--experience in fifty patients.
    Nagral A; Waravdekar G; Nisar P; Someshwar V; Sadana N; Sampat M; Patel K
    Indian J Gastroenterol; 2003; 22(5):173-5. PubMed ID: 14658532
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Diagnostic value of transjugular liver biopsy in liver transplant recipients].
    Romero M; Bañares R; Salcedo M; Alvarez E; Peligros I; Clemente G; Cos E
    Gastroenterol Hepatol; 1999 Dec; 22(10):493-6. PubMed ID: 10650662
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transjugular liver biopsy: a prospective study in 43 patients with the Quick-Core biopsy needle.
    Little AF; Zajko AB; Orons PD
    J Vasc Interv Radiol; 1996; 7(1):127-31. PubMed ID: 8773987
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: a retrospective review of 410 consecutive procedures.
    Smith TP; Presson TL; Heneghan MA; Ryan JM
    AJR Am J Roentgenol; 2003 Jan; 180(1):167-72. PubMed ID: 12490497
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy.
    Ishikawa T; Kamimura H; Tsuchiya A; Togashi T; Watanabe K; Seki K; Ohta H; Yoshida T; Ishihara N; Kamimura T
    World J Gastroenterol; 2006 Oct; 12(39):6339-42. PubMed ID: 17072958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Transjugular liver biopsy: retrospective study performed on 71 patients].
    Quevedo E; Tan J; Araujo G; Morales H; Távara F
    Rev Gastroenterol Peru; 2003; 23(4):254-8. PubMed ID: 14716419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transjugular liver biopsy: indications, technique and results.
    Dohan A; Guerrache Y; Boudiaf M; Gavini JP; Kaci R; Soyer P
    Diagn Interv Imaging; 2014 Jan; 95(1):11-5. PubMed ID: 24007769
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transjugular liver biopsy: modified Ross transseptal needle versus quick-core biopsy needle.
    Choo SW; Do YS; Park KB; Kim SH; Han YH; Choo I
    Abdom Imaging; 2000; 25(5):483-5. PubMed ID: 10931981
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transjugular liver biopsy: a review of 200 biopsies.
    Corr P; Beningfield SJ; Davey N
    Clin Radiol; 1992 Apr; 45(4):238-9. PubMed ID: 1395377
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transvenous (transjugular) liver biopsy. An experience based on 100 biopsies.
    Lebrec D; Degott C; Rueff B; Benhamou JP
    Am J Dig Dis; 1978 Apr; 23(4):302-4. PubMed ID: 665623
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Hepatic puncture biopsy by the transjugular route].
    Lebrec D; Buysschaert M; Degott C; Rueff B; Benhamou JP
    Nouv Presse Med; 1976 Oct; 5(9 Oct 76):2135-7. PubMed ID: 980772
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transjugular liver biopsy effecting changes in clinical management.
    Lee D; Chitturi S; Kench J; George J; Fuller S; Bradstock K; Lin R; Wong KP; Young N
    Australas Radiol; 2003 Jun; 47(2):117-20. PubMed ID: 12780438
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transjugular liver biopsy with an automated trucut-type needle: comparative study with percutaneous liver biopsy.
    Chau TN; Tong SW; Li TM; To HT; Lee KC; Lai JY; Lai ST; Yuen H
    Eur J Gastroenterol Hepatol; 2002 Jan; 14(1):19-24. PubMed ID: 11782571
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Experience in patients with suspected chronic liver disease and contraindication for percutaneous biopsy using modified Ross needle].
    Maciel AC; de Barros SG; Tarasconi DP; Severo Júnior LC; Cerski CT; Ilha Dde O
    Rev Assoc Med Bras (1992); 2000; 46(2):134-42. PubMed ID: 11022354
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic yield of transjugular liver biopsy samples to evaluate for infectious etiology of liver dysfunction in bone marrow transplant recipients.
    Nadolski G; Mondschein JI; Shlansky-Goldberg RD; Stavropoulos SW; Soulen MC; Dagli MS; Clark TW; Trerotola SO
    Cardiovasc Intervent Radiol; 2014 Apr; 37(2):471-5. PubMed ID: 23760757
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.