These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 18783996)

  • 1. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictors of fracture risk of a small caliber implantable cardioverter defibrillator lead.
    Ha AC; Vezi BZ; Keren A; Alanazi H; Gollob MH; Green MS; Lemery R; Nery PB; Posan E; Birnie DH
    Pacing Clin Electrophysiol; 2010 Apr; 33(4):437-43. PubMed ID: 19954500
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of lead failure manifestation of Biotronik Linox with St. Jude Medical Riata and Medtronic Sprint Fidelis lead.
    Lam A; Buehler S; Goulouti E; Sweda R; Haeberlin A; Medeiros-Domingo A; Servatius H; Seiler J; Baldinger S; Noti F; Tanner H; Roten L
    J Interv Card Electrophysiol; 2019 Mar; 54(2):161-170. PubMed ID: 30471050
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure.
    Hauser RG; Hayes DL
    Heart Rhythm; 2009 May; 6(5):605-10. PubMed ID: 19285920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead.
    Hauser RG; Kallinen LM; Almquist AK; Gornick CC; Katsiyiannis WT
    Heart Rhythm; 2007 Jul; 4(7):892-6. PubMed ID: 17599673
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
    Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD
    Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lead electrical parameters may not predict integrity of the Sprint Fidelis ICD lead.
    Maytin M; Epstein LM
    Heart Rhythm; 2012 Sep; 9(9):1446-51. PubMed ID: 22537883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for implantable defibrillator lead fracture in a recalled and a nonrecalled lead.
    Morrison TB; Rea RF; Hodge DO; Crusan D; Koestler C; Asirvatham SJ; Bradley D; Shen WK; Munger TM; Hammill SC; Friedman PA
    J Cardiovasc Electrophysiol; 2010 Jun; 21(6):671-7. PubMed ID: 20082653
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?
    Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M
    Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of implanted recalled sprint Fidelis lead on patient mortality.
    Morrison TB; Friedman PA; Kallinen LM; Hodge DO; Crusan D; Kumar K; Hayes DL; Rea RF; Hauser RG
    J Am Coll Cardiol; 2011 Jul; 58(3):278-83. PubMed ID: 21737019
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk of Sprint Fidelis defibrillator lead failure is highly dependent on age.
    Girerd N; Nonin E; Pinot J; Morel E; Flys C; Scridon A; Chevalier P
    Arch Cardiovasc Dis; 2011; 104(6-7):388-95. PubMed ID: 21798471
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical predictors of Fidelis lead failure: report from the Canadian Heart Rhythm Society Device Committee.
    Birnie DH; Parkash R; Exner DV; Essebag V; Healey JS; Verma A; Coutu B; Kus T; Mangat I; Ayala-Paredes F; Nery P; Wells G; Krahn AD
    Circulation; 2012 Mar; 125(10):1217-25. PubMed ID: 22311781
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Very late follow-up of a passive defibrillator lead under recall: do failure rates increase during long-term observation.
    Frey SM; Sticherling C; Kraus R; Ammann P; Kühne M; Osswald S; Schaer B
    Pacing Clin Electrophysiol; 2015 Mar; 38(3):306-10. PubMed ID: 25599764
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.