These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 18790482)

  • 1. Extraction of amphetamines and methylenedioxyamphetamines from urine using a monolithic silica disk-packed spin column and high-performance liquid chromatography-diode array detection.
    Namera A; Nakamoto A; Nishida M; Saito T; Kishiyama I; Miyazaki S; Yahata M; Yashiki M; Nagao M
    J Chromatogr A; 2008 Oct; 1208(1-2):71-5. PubMed ID: 18790482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection.
    Nakamoto A; Nishida M; Saito T; Kishiyama I; Miyazaki S; Murakami K; Nagao M; Namura A
    Anal Chim Acta; 2010 Feb; 661(1):42-6. PubMed ID: 20113714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous extraction of acidic and basic drugs from urine using mixed-mode monolithic silica spin column bonded with octadecyl and cation-exchange group.
    Namera A; Yamamoto S; Saito T; Miyazaki S; Oikawa H; Nakamoto A; Nagao M
    J Sep Sci; 2011 Aug; 34(16-17):2232-9. PubMed ID: 21648080
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dispersive solid-phase microextraction method for sample extraction in the analysis of four tetracyclines in water and milk samples by high-performance liquid chromatography with diode-array detection.
    Tsai WH; Huang TC; Huang JJ; Hsue YH; Chuang HY
    J Chromatogr A; 2009 Mar; 1216(12):2263-9. PubMed ID: 19185868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monolithic columns in high-performance liquid chromatography.
    Guiochon G
    J Chromatogr A; 2007 Oct; 1168(1-2):101-68; discussion 100. PubMed ID: 17640660
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of antihyperglycemic biguanides in serum and urine using an ion-pair solid-phase extraction technique followed by HPLC-UV on a pentafluorophenylpropyl column and on an octadecyl column.
    Tahara K; Yonemoto A; Yoshiyama Y; Nakamura T; Aizawa M; Fujita Y; Nishikawa T
    Biomed Chromatogr; 2006 Nov; 20(11):1200-5. PubMed ID: 16799926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New screening method for basic compounds in urine by on-line extraction-high-performance liquid chromatography with photodiode-array detection.
    Schönberg L; Grobosch T; Lampe D; Kloft C
    J Chromatogr A; 2006 Nov; 1134(1-2):177-85. PubMed ID: 16999974
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of N(G)-monomethyl-L-arginine, N(G),N(G)-dimethyl-L-arginine, N(G),N(G')-dimethyl-L-arginine, and L-arginine using monolithic silica disk-packed spin columns and a monolithic silica column.
    Nonaka S; Sekine M; Tsunoda M; Ozeki Y; Fujii K; Akiyama K; Shimoda K; Furuchi T; Katane M; Saitoh Y; Homma H
    J Sep Sci; 2014 Aug; 37(16):2087-94. PubMed ID: 24895248
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of wide-pore monolithic silica column in protein separation.
    Morisaka H; Kobayashi K; Kirino A; Furuno M; Minakuchi H; Nakanishi K; Ueda M
    J Sep Sci; 2009 Aug; 32(15-16):2747-51. PubMed ID: 19575377
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extraction of trace amounts of pioglitazone as an anti-diabetic drug with hollow fiber liquid phase microextraction and determination by high-performance liquid chromatography-ultraviolet detection in biological fluids.
    Tahmasebi E; Yamini Y; Saleh A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jul; 877(20-21):1923-9. PubMed ID: 19501030
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of zonisamide by a coated monolithic column.
    Li J; Wu G; Zhu Y
    J Chromatogr A; 2006 Jun; 1118(1):151-4. PubMed ID: 16595139
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography.
    Skudas R; Grimes BA; Thommes M; Unger KK
    J Chromatogr A; 2009 Mar; 1216(13):2625-36. PubMed ID: 19233368
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation of hydrophobic metabolites using monolithic silica column in high-performance liquid chromatography and supercritical fluid chromatography.
    Bamba T; Fukusaki E
    J Sep Sci; 2009 Aug; 32(15-16):2699-706. PubMed ID: 19606440
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amino acids analysis using a monolithic silica column after derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F).
    Song Y; Funatsu T; Tsunoda M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Feb; 879(5-6):335-40. PubMed ID: 21242111
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Synthesis of penetrable macroporous silica spheres for high-performance liquid chromatography.
    Wei JX; Shi ZG; Chen F; Feng YQ; Guo QZ
    J Chromatogr A; 2009 Oct; 1216(44):7388-93. PubMed ID: 19442982
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrokinetic extraction on artificial liquid membranes of amphetamine-type stimulants from urine samples followed by high performance liquid chromatography analysis.
    Seidi S; Yamini Y; Baheri T; Feizbakhsh R
    J Chromatogr A; 2011 Jul; 1218(26):3958-65. PubMed ID: 21621215
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation of monolithic silica columns for high-performance liquid chromatography.
    Núñez O; Nakanishi K; Tanaka N
    J Chromatogr A; 2008 May; 1191(1-2):231-52. PubMed ID: 18313061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Selectivity comparisons of monolithic silica capillary columns modified with poly(octadecyl methacrylate) and octadecyl moieties for halogenated compounds in reversed-phase liquid chromatography.
    Soonthorntantikul W; Leepipatpiboon N; Ikegami T; Tanaka N; Nhujak T
    J Chromatogr A; 2009 Jul; 1216(31):5868-74. PubMed ID: 19560150
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid and high-resolution analysis of geometric polyprenol homologues by connected octadecylsilylated monolithic silica columns in high-performance liquid chromatography.
    Bamba T; Fukusaki E; Nakazawa Y; Kobayashi A
    J Sep Sci; 2004 Mar; 27(4):293-6. PubMed ID: 15334916
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparation of high efficiency and highly retentive monolithic silica capillary columns for reversed-phase chromatography by chemical modification by polymerization of octadecyl methacrylate.
    Núñez O; Ikegami T; Kajiwara W; Miyamoto K; Horie K; Tanaka N
    J Chromatogr A; 2007 Jul; 1156(1-2):35-44. PubMed ID: 17188698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.