BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

293 related articles for article (PubMed ID: 18799395)

  • 1. Image-guided 256-element phased-array focused ultrasound surgery.
    Lu M; Wang X; Wan M; Feng Y; Xu F; Zhong H; Tan J
    IEEE Eng Med Biol Mag; 2008; 27(5):84-90. PubMed ID: 18799395
    [No Abstract]   [Full Text] [Related]  

  • 2. [Genetic algorithm application to multi-focus patterns of 256-element phased array for focused ultrasound surgery].
    Xu F; Wan M; Lu M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1093-7. PubMed ID: 19024453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and experiment of 256-element ultrasound phased array for noninvasive focused ultrasound surgery.
    Lu M; Wan M; Xu F; Wang X; Chang X
    Ultrasonics; 2006 Dec; 44 Suppl 1():e325-30. PubMed ID: 16949119
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Ultrasound-guided interventions and description of the equipment].
    Gottschalk U; Ignee A; Dietrich CF
    Z Gastroenterol; 2010 Nov; 48(11):1305-16. PubMed ID: 21043010
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3-D ultrasound guidance of surgical robotics using catheter transducers: feasibility study.
    Whitman J; Fronheiser MP; Smith SW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 May; 55(5):1143-5. PubMed ID: 18519222
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endoneurosonography: technique and equipment, anatomy and imaging, and clinical application.
    Resch KD
    Neurosurgery; 2008 Dec; 63(6):E1209; author reply E1209. PubMed ID: 19057297
    [No Abstract]   [Full Text] [Related]  

  • 7. Principles and devices.
    Kopchok GE; Donayre CE; White RA
    Semin Vasc Surg; 2006 Sep; 19(3):128-31. PubMed ID: 16996413
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An image-guided high intensity focused ultrasound device for uterine fibroids treatment.
    Chan AH; Fujimoto VY; Moore DE; Martin RW; Vaezy S
    Med Phys; 2002 Nov; 29(11):2611-20. PubMed ID: 12462728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image-guided acoustic hemostasis for hemorrhage in the posterior liver.
    Burgess S; Zderic V; Vaezy S
    Ultrasound Med Biol; 2007 Jan; 33(1):113-9. PubMed ID: 17189053
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study.
    Ho CS; Ju KC; Cheng TY; Chen YY; Lin WL
    Phys Med Biol; 2007 Aug; 52(15):4585-99. PubMed ID: 17634652
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [High-intensity focused ultrasound transducer].
    Fu L; Li F
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Jun; 26(3):667-70. PubMed ID: 19634694
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetic resonance guided focalised ultrasound thermo-ablation: a promising oncologic local therapy.
    Iannessi A; Doyen J; Leysalle A; Thyss A
    Diagn Interv Imaging; 2014 Mar; 95(3):339-43. PubMed ID: 24589188
    [No Abstract]   [Full Text] [Related]  

  • 13. An ultrasound cylindrical phased array for deep heating in the breast: theoretical design using heterogeneous models.
    Bakker JF; Paulides MM; Obdeijn IM; van Rhoon GC; van Dongen KW
    Phys Med Biol; 2009 May; 54(10):3201-15. PubMed ID: 19420416
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Focused beam control for ultrasound surgery with spherical-section phased array: sound field calculation and genetic optimization algorithm.
    Lu M; Wan M; Xu F; Wang X; Zhong H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Aug; 52(8):1270-90. PubMed ID: 16245597
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and experimental evaluations of a low-frequency hemispherical ultrasound phased-array system for transcranial blood-brain barrier disruption.
    Liu HL; Chen HW; Kuo ZH; Huang WC
    IEEE Trans Biomed Eng; 2008 Oct; 55(10):2407-16. PubMed ID: 18838366
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.
    Hynynen K; Jones RM
    Phys Med Biol; 2016 Sep; 61(17):R206-48. PubMed ID: 27494561
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A fully automatic calibration framework for navigated ultrasound imaging.
    Peterhans M; Anderegg S; Gaillard P; Oliveira-Santos T; Weber S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1242-5. PubMed ID: 21096125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Miniaturized ultrasound arrays for interstitial ablation and imaging.
    Makin IR; Mast TD; Faidi W; Runk MM; Barthe PG; Slayton MH
    Ultrasound Med Biol; 2005 Nov; 31(11):1539-50. PubMed ID: 16286031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [A multifrequency phase-controlled driving system for ultrasound therapy].
    Dai QJ; Zhou QW; Xu XZ; Ou Yang KY; Bian ZZ
    Zhongguo Yi Liao Qi Xie Za Zhi; 2002 Jul; 26(4):256-8. PubMed ID: 16104277
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Toward a comprehensive hybrid physical-virtual reality simulator of peripheral anesthesia with ultrasound and neurostimulator guidance.
    Samosky JT; Allen P; Boronyak S; Branstetter B; Hein S; Juhas M; Nelson DA; Orebaugh S; Pinto R; Smelko A; Thompson M; Weaver RA
    Stud Health Technol Inform; 2011; 163():552-4. PubMed ID: 21335855
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.