These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

375 related articles for article (PubMed ID: 18801810)

  • 1. eComment: double-knotted Swan-Ganz catheter--potential for non-invasive ultrasonic cardiac output monitoring?
    Knobloch K
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):862-3. PubMed ID: 18801810
    [No Abstract]   [Full Text] [Related]  

  • 2. Review article: Non-invasive assessment of cardiac output with portable continuous-wave Doppler ultrasound.
    Meyer S; Todd D; Wright I; Gortner L; Reynolds G
    Emerg Med Australas; 2008 Jun; 20(3):201-8. PubMed ID: 18400002
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical validation of the non-invasive cardiac output monitor USCOM-1A in critically ill patients.
    van Lelyveld-Haas LE; van Zanten AR; Borm GF; Tjan DH
    Eur J Anaesthesiol; 2008 Nov; 25(11):917-24. PubMed ID: 18652712
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative removal of a knotted Swan-Ganz catheter during lung transplantation.
    de Jesus Peixoto Camargo J; Marcantonio Camargo S; Noguchi Machuca T; Wagner P
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):861-2. PubMed ID: 18653497
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral percutaneous removal of a knotted Swan-Ganz catheter.
    Katsikis A; Karavolias G; Voudris V
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):802-4. PubMed ID: 19830792
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter.
    Gueret G; Kiss G; Rossignol B; Bezon E; Wargnier JP; Miossec A; Corre O; Arvieux CC
    Eur J Anaesthesiol; 2006 Oct; 23(10):848-54. PubMed ID: 16953944
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The fiber optic Swan-Ganz catheter. The monitoring of SvO2].
    Solé Fábregas A; Salas Campos L
    Rev Enferm; 1994 May; 17(189):75-9. PubMed ID: 8009165
    [No Abstract]   [Full Text] [Related]  

  • 8. Cardiac arrhythmias related to continuous thermodilution cardiac output measurement in an anaesthetized sheep.
    Coppens P; Moens Y
    Lab Anim; 2009 Jul; 43(3):291-4. PubMed ID: 19237458
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Hemodynamic monitoring: Swan-Ganz catheter].
    Palencia Herrejón E; Ruiz González F
    Rev Clin Esp; 1997 Dec; 197 Suppl 4():3-12. PubMed ID: 9542424
    [No Abstract]   [Full Text] [Related]  

  • 10. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Indications for Swan-Ganz catheterization.
    Hebert KA; Glancy DL
    Heart Dis Stroke; 1994; 3(4):196-200. PubMed ID: 7921663
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Erroneous cardiac output measurement due to loop formation of a Swan-Ganz catheter in the pulmonary artery.
    Schummer W; Schummer C; Schummer C
    J Clin Anesth; 2004 May; 16(3):235-6. PubMed ID: 15217669
    [No Abstract]   [Full Text] [Related]  

  • 13. Percutaneous untying of a knot in a retained Swan-Ganz catheter.
    Bhatti WA; Sinha S; Rowlands P
    Cardiovasc Intervent Radiol; 2000; 23(3):224-5. PubMed ID: 10821898
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Re: "Erroneous cardiac output measurement due to loop formation of a swan-ganz catheter in the pulmonary artery".
    Madan M
    J Clin Anesth; 2005 Mar; 17(2):151; author reply 151. PubMed ID: 15809140
    [No Abstract]   [Full Text] [Related]  

  • 15. Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?
    Perrino AC
    Yale J Biol Med; 1993; 66(5):397-413. PubMed ID: 7825341
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Non-surgical removal of a knotted Swan-Ganz catheter].
    Böttiger BW; Schmidt H; Böhrer H; Martin E
    Anaesthesist; 1991 Dec; 40(12):682-6. PubMed ID: 1781566
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Removal of a knotted Swan-Ganz catheter.
    Rahim SA; Franke R; Mathew V
    J Am Coll Cardiol; 2009 Jun; 53(23):e91. PubMed ID: 19497436
    [No Abstract]   [Full Text] [Related]  

  • 18. eComment: Non-invasive ultrasonic cardiac output monitoring in the surgical operating room.
    Knobloch K
    Interact Cardiovasc Thorac Surg; 2009 Jun; 8(6):646. PubMed ID: 19443494
    [No Abstract]   [Full Text] [Related]  

  • 19. Transfemoral removal of a knotted Swan-Ganz catheter.
    Papakostas JC; Papadopoulos LS; Arnaoutoglou HM; Karahaliou A; Matsagas MI
    Can J Surg; 2008 Oct; 51(5):E107-8. PubMed ID: 18841211
    [No Abstract]   [Full Text] [Related]  

  • 20. Continuous cardiac output measurement with a Doppler-equipped pulmonary artery catheter.
    Akamatsu S; Kondo Y; Ueda N; Kojima A; Fukuoka N; Takada M; Dohi S; Hashimoto T
    Anesth Analg; 2011 Apr; 112(4):851-7. PubMed ID: 21288977
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.