BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 18803058)

  • 1. Validation of Varian's AAA algorithm with focus on lung treatments.
    Rønde HS; Hoffmann L
    Acta Oncol; 2009; 48(2):209-15. PubMed ID: 18803058
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implementation and experimental validation of the high dose rate stereotactic treatment mode at Varian accelerators.
    Hoffmann L
    Acta Oncol; 2009; 48(2):201-8. PubMed ID: 18759143
    [TBL] [Abstract][Full Text] [Related]  

  • 3. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
    Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
    Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification.
    Bragg CM; Wingate K; Conway J
    Radiother Oncol; 2008 Feb; 86(2):276-84. PubMed ID: 18249453
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
    Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
    Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning.
    Bragg CM; Conway J
    Radiother Oncol; 2006 Dec; 81(3):315-23. PubMed ID: 17125862
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water.
    Fogliata A; Nicolini G; Vanetti E; Clivio A; Cozzi L
    Phys Med Biol; 2006 Mar; 51(6):1421-38. PubMed ID: 16510953
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
    Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
    Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage.
    Aarup LR; Nahum AE; Zacharatou C; Juhler-Nøttrup T; Knöös T; Nyström H; Specht L; Wieslander E; Korreman SS
    Radiother Oncol; 2009 Jun; 91(3):405-14. PubMed ID: 19297051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of the dose calculation accuracy for IMRT in lung: a 2D approach.
    Dvorak P; Stock M; Kroupa B; Bogner J; Georg D
    Acta Oncol; 2007; 46(7):928-36. PubMed ID: 17917824
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Testing of the analytical anisotropic algorithm for photon dose calculation.
    Van Esch A; Tillikainen L; Pyykkonen J; Tenhunen M; Helminen H; Siljamäki S; Alakuijala J; Paiusco M; Lori M; Huyskens DP
    Med Phys; 2006 Nov; 33(11):4130-48. PubMed ID: 17153392
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device.
    Kavuma A; Glegg M; Metwaly M; Currie G; Elliott A
    Phys Med Biol; 2010 Jan; 55(2):435-52. PubMed ID: 20019398
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of dose calculation algorithms for static and rotational IMRT of lung cancer: A phantom study.
    Sini C; Broggi S; Fiorino C; Cattaneo GM; Calandrino R
    Phys Med; 2015 Jun; 31(4):382-90. PubMed ID: 25801284
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The impact of photon dose calculation algorithms on expected dose distributions in lungs under different respiratory phases.
    Fogliata A; Nicolini G; Vanetti E; Clivio A; Winkler P; Cozzi L
    Phys Med Biol; 2008 May; 53(9):2375-90. PubMed ID: 18421117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases.
    Hasenbalg F; Neuenschwander H; Mini R; Born EJ
    Phys Med Biol; 2007 Jul; 52(13):3679-91. PubMed ID: 17664570
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric evaluation of a Monte Carlo IMRT treatment planning system incorporating the MIMiC.
    Rassiah-Szegedi P; Fuss M; Sheikh-Bagheri D; Szegedi M; Stathakis S; Lancaster J; Papanikolaou N; Salter B
    Phys Med Biol; 2007 Dec; 52(23):6931-41. PubMed ID: 18029985
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo modeling of the ModuLeaf miniature MLC for small field dosimetry and quality assurance of the clinical treatment planning system.
    Crop F; Reynaert N; Pittomvils G; Paelinck L; De Gersem W; De Wagter C; Vakaet L; De Neve W; Thierens H
    Phys Med Biol; 2007 Jun; 52(11):3275-90. PubMed ID: 17505102
    [TBL] [Abstract][Full Text] [Related]  

  • 18. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems.
    Panettieri V; Wennberg B; Gagliardi G; Duch MA; Ginjaume M; Lax I
    Phys Med Biol; 2007 Jul; 52(14):4265-81. PubMed ID: 17664607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm.
    Yoo S; Wu Q; O'Daniel J; Horton J; Yin FF
    Radiother Oncol; 2012 May; 103(2):172-7. PubMed ID: 22349127
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical validation of the Acuros XB photon dose calculation algorithm, a grid-based Boltzmann equation solver.
    Hoffmann L; Jørgensen MB; Muren LP; Petersen JB
    Acta Oncol; 2012 Mar; 51(3):376-85. PubMed ID: 22060134
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.