These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 18822398)

  • 1. Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.
    Fajardo RJ; Cory E; Patel ND; Nazarian A; Laib A; Manoharan RK; Schmitz JE; DeSilva JM; MacLatchy LM; Snyder BD; Bouxsein ML
    Bone; 2009 Jan; 44(1):176-84. PubMed ID: 18822398
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom.
    Deuerling JM; Rudy DJ; Niebur GL; Roeder RK
    Med Phys; 2010 Sep; 37(9):5138-45. PubMed ID: 20964233
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: comparison with synchrotron radiation microcomputed tomography and ash measurements.
    Kazakia GJ; Burghardt AJ; Cheung S; Majumdar S
    Med Phys; 2008 Jul; 35(7):3170-9. PubMed ID: 18697542
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enamel lesion parameter correlations between polychromatic micro-CT and TMR.
    Hamba H; Nikaido T; Sadr A; Nakashima S; Tagami J
    J Dent Res; 2012 Jun; 91(6):586-91. PubMed ID: 22476867
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of polychromatic µCT for mineral density determination.
    Zou W; Hunter N; Swain MV
    J Dent Res; 2011 Jan; 90(1):18-30. PubMed ID: 20858779
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.
    Meganck JA; Kozloff KM; Thornton MM; Broski SM; Goldstein SA
    Bone; 2009 Dec; 45(6):1104-16. PubMed ID: 19651256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative assessment of bone tissue mineralization with polychromatic micro-computed tomography.
    Burghardt AJ; Kazakia GJ; Laib A; Majumdar S
    Calcif Tissue Int; 2008 Aug; 83(2):129-38. PubMed ID: 18685797
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.
    Nazarian A; Snyder BD; Zurakowski D; Müller R
    Bone; 2008 Aug; 43(2):302-311. PubMed ID: 18539557
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of micro-computed tomography reconstruction protocols on bone microarchitecture analysis.
    Nascimento EHL; Gaêta-Araujo H; Brasil DM; Madlum DV; Freitas DQ; Haiter-Neto F; Oliveira-Santos C
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2019 Oct; 128(4):411-417. PubMed ID: 31196704
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 3D assessment of cortical bone porosity and tissue mineral density using high-resolution µCT: effects of resolution and threshold method.
    Palacio-Mancheno PE; Larriera AI; Doty SB; Cardoso L; Fritton SP
    J Bone Miner Res; 2014 Jan; 29(1):142-50. PubMed ID: 23775635
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of voxel values in micro computed tomography using multiple porosity hydroxyapatite blocks.
    Naitoh M; Watanabe H; Kuwana R; Hishikawa T; Hayashi H; Miyamae S; Mitani A; Ariji E
    Okajimas Folia Anat Jpn; 2018; 95(1):9-13. PubMed ID: 30101950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Surrogate Measure of Cortical Bone Matrix Density by Long T2 -Suppressed MRI.
    Seifert AC; Li C; Wehrli SL; Wehrli FW
    J Bone Miner Res; 2015 Dec; 30(12):2229-38. PubMed ID: 26085307
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Distortional effect of beam-hardening artefacts on microCT: a simulation study based on an in vitro caries model.
    Kovács M; Danyi R; Erdélyi M; Fejérdy P; Dobó-Nagy C
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Oct; 108(4):591-9. PubMed ID: 19778746
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms.
    Palanca M; Bodey AJ; Giorgi M; Viceconti M; Lacroix D; Cristofolini L; Dall'Ara E
    J Biomech; 2017 Jun; 58():27-36. PubMed ID: 28457604
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of porosity and pore size on the ultrasonic properties of bone investigated using a phantom material.
    Strelitzki R; Evans JA; Clarke AJ
    Osteoporos Int; 1997; 7(4):370-5. PubMed ID: 9373573
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of the structure and permeability of titanium foams for spinal fusion devices.
    Singh R; Lee PD; Lindley TC; Dashwood RJ; Ferrie E; Imwinkelried T
    Acta Biomater; 2009 Jan; 5(1):477-87. PubMed ID: 18657494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Volume to density relation in adult human bone tissue.
    Tassani S; Ohman C; Baruffaldi F; Baleani M; Viceconti M
    J Biomech; 2011 Jan; 44(1):103-8. PubMed ID: 20850118
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Significant correlations between human cortical bone mineral density and quantitative susceptibility mapping (QSM) obtained with 3D Cones ultrashort echo time magnetic resonance imaging (UTE-MRI).
    Jerban S; Lu X; Jang H; Ma Y; Namiranian B; Le N; Li Y; Chang EY; Du J
    Magn Reson Imaging; 2019 Oct; 62():104-110. PubMed ID: 31247253
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis.
    Gaêta-Araujo H; Oliveira-Santos N; Brasil DM; do Nascimento EHL; Madlum DV; Haiter-Neto F; Oliveira-Santos C
    Dentomaxillofac Radiol; 2019 Dec; 48(8):20190235. PubMed ID: 31408366
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Agreement and precision of periprosthetic bone density measurements in micro-CT, single and dual energy CT.
    Mussmann B; Overgaard S; Torfing T; Traise P; Gerke O; Andersen PE
    J Orthop Res; 2017 Jul; 35(7):1470-1477. PubMed ID: 27600874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.