These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
758 related articles for article (PubMed ID: 18830696)
1. Development of high throughput optical sensor array for on-line pH monitoring in micro-scale cell culture environment. Wu MH; Lin JL; Wang J; Cui Z; Cui Z Biomed Microdevices; 2009 Feb; 11(1):265-73. PubMed ID: 18830696 [TBL] [Abstract][Full Text] [Related]
2. Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism. Wu MH; Wang J; Taha T; Cui Z; Urban JP; Cui Z Biomed Microdevices; 2007 Apr; 9(2):167-74. PubMed ID: 17160706 [TBL] [Abstract][Full Text] [Related]
3. An in line non-invasive optical system to monitor pH in cell and tissue culture. Xu X; Smith S; Urban J; Cui Z Med Eng Phys; 2006 Jun; 28(5):468-74. PubMed ID: 16129647 [TBL] [Abstract][Full Text] [Related]
4. Comparisons of optical pH and dissolved oxygen sensors with traditional electrochemical probes during mammalian cell culture. Hanson MA; Ge X; Kostov Y; Brorson KA; Moreira AR; Rao G Biotechnol Bioeng; 2007 Jul; 97(4):833-41. PubMed ID: 17216654 [TBL] [Abstract][Full Text] [Related]
5. Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays. Hung PJ; Lee PJ; Sabounchi P; Lin R; Lee LP Biotechnol Bioeng; 2005 Jan; 89(1):1-8. PubMed ID: 15580587 [TBL] [Abstract][Full Text] [Related]
6. Micro-bioreactors for fed-batch fermentations with integrated online monitoring and microfluidic devices. Buchenauer A; Hofmann MC; Funke M; Büchs J; Mokwa W; Schnakenberg U Biosens Bioelectron; 2009 Jan; 24(5):1411-6. PubMed ID: 18929478 [TBL] [Abstract][Full Text] [Related]
7. Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices. Lin CF; Lee GB; Wang CH; Lee HH; Liao WY; Chou TC Biosens Bioelectron; 2006 Feb; 21(8):1468-75. PubMed ID: 16099154 [TBL] [Abstract][Full Text] [Related]
8. Validation of an optical sensor-based high-throughput bioreactor system for mammalian cell culture. Ge X; Hanson M; Shen H; Kostov Y; Brorson KA; Frey DD; Moreira AR; Rao G J Biotechnol; 2006 Apr; 122(3):293-306. PubMed ID: 16423420 [TBL] [Abstract][Full Text] [Related]
9. Microfluidic sorting system based on optical waveguide integration and diode laser bar trapping. Applegate RW; Squier J; Vestad T; Oakey J; Marr DW; Bado P; Dugan MA; Said AA Lab Chip; 2006 Mar; 6(3):422-6. PubMed ID: 16511626 [TBL] [Abstract][Full Text] [Related]
10. A high throughput perfusion-based microbioreactor platform integrated with pneumatic micropumps for three-dimensional cell culture. Wu MH; Huang SB; Cui Z; Cui Z; Lee GB Biomed Microdevices; 2008 Apr; 10(2):309-19. PubMed ID: 18026840 [TBL] [Abstract][Full Text] [Related]
11. An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models. Kimura H; Yamamoto T; Sakai H; Sakai Y; Fujii T Lab Chip; 2008 May; 8(5):741-6. PubMed ID: 18432344 [TBL] [Abstract][Full Text] [Related]
12. Microfluidic cell culture chip with multiplexed medium delivery and efficient cell/scaffold loading mechanisms for high-throughput perfusion 3-dimensional cell culture-based assays. Huang SB; Wu MH; Wang SS; Lee GB Biomed Microdevices; 2011 Jun; 13(3):415-30. PubMed ID: 21234690 [TBL] [Abstract][Full Text] [Related]
13. A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array. Hung PJ; Lee PJ; Sabounchi P; Aghdam N; Lin R; Lee LP Lab Chip; 2005 Jan; 5(1):44-8. PubMed ID: 15616739 [TBL] [Abstract][Full Text] [Related]
14. Investigation of portable in situ fluorescence optical detection for microfluidic 3D cell culture assays. Choi JR; Sung JH; Shuler ML; Kim D Opt Lett; 2010 May; 35(9):1374-6. PubMed ID: 20436574 [TBL] [Abstract][Full Text] [Related]
15. Microfluidic flow rate detection based on integrated optical fiber cantilever. Lien V; Vollmer F Lab Chip; 2007 Oct; 7(10):1352-6. PubMed ID: 17896021 [TBL] [Abstract][Full Text] [Related]
16. Integrated microfluidic system for electrochemical sensing of urinary proteins. Liu CY; Rick J; Chou TC; Lee HH; Lee GB Biomed Microdevices; 2009 Feb; 11(1):201-11. PubMed ID: 18792782 [TBL] [Abstract][Full Text] [Related]
18. A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate. Wu MH; Cai H; Xu X; Urban JP; Cui ZF; Cui Z Biomed Microdevices; 2005 Dec; 7(4):323-9. PubMed ID: 16404510 [TBL] [Abstract][Full Text] [Related]
19. Microbioreactor arrays with integrated mixers and fluid injectors for high-throughput experimentation with pH and dissolved oxygen control. Lee HL; Boccazzi P; Ram RJ; Sinskey AJ Lab Chip; 2006 Sep; 6(9):1229-35. PubMed ID: 16929403 [TBL] [Abstract][Full Text] [Related]
20. Design of MEMS devices with optical apertures for the detection of transparent biological cells. Zhou X; Poenar DP; Liu KY; Tse MS; Heng CK; Tan SN Biomed Microdevices; 2008 Oct; 10(5):639-52. PubMed ID: 18443909 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]