376 related articles for article (PubMed ID: 18834462)
1. Effect of atrial lead position on atrial automatic capture verification.
Butter C; Zhang G; Seifert M; Minden HH; König A; Fleck E
Pacing Clin Electrophysiol; 2008 Sep; 31(9):1118-24. PubMed ID: 18834462
[TBL] [Abstract][Full Text] [Related]
2. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.
Sperzel J; Goetze S; Kennergren C; Biffi M; Brooke MJ; Vireca E; Saha S; Schubert B; Butter C
Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578
[TBL] [Abstract][Full Text] [Related]
3. Muscle noise effects on atrial evoked response sensing: implications on atrial auto-threshold and auto-capture determination.
Tse HF; Saha S; Garg A; Bohn D; Lee YL; Lau CP
Pacing Clin Electrophysiol; 2011 Apr; 34(4):460-6. PubMed ID: 21208231
[TBL] [Abstract][Full Text] [Related]
4. Anodal capture in cardiac resynchronization therapy implications for device programming.
Tamborero D; Mont L; Alanis R; Berruezo A; Tolosana JM; Sitges M; Vidal B; Brugada J
Pacing Clin Electrophysiol; 2006 Sep; 29(9):940-5. PubMed ID: 16981916
[TBL] [Abstract][Full Text] [Related]
5. Clinical evaluation of two different evoked response sensing methods for automatic capture detection in the left ventricle.
Goetze S; Sperzel J; Biffi M; Sathaye A; Brooke MJ; Doelger A; Schubert B; Butter C
Pacing Clin Electrophysiol; 2007 Jul; 30(7):865-73. PubMed ID: 17584268
[TBL] [Abstract][Full Text] [Related]
6. Performance of a ventricular automatic-capture algorithm in a wide clinical setting.
Pecora D; Morandi F; Liccardo M; Pepi P; Orazi S; Caico SI; Scaccia A; Bizeau O; Citerne O; Raciti G; Del Giudice G
Pacing Clin Electrophysiol; 2008 Dec; 31(12):1546-53. PubMed ID: 19067806
[TBL] [Abstract][Full Text] [Related]
7. Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing.
Lewicka-Nowak E; Kutarski A; Dabrowska-Kugacka A; Rucinski P; Zagozdzon P; Raczak G
Europace; 2008 Feb; 10(2):138-46. PubMed ID: 18192341
[TBL] [Abstract][Full Text] [Related]
8. Electrocardiogram-based algorithm to predict the left ventricular lead position in recipients of cardiac resynchronization systems.
Ploux S; Bordachar P; Deplagne A; Mokrani B; Reuter S; Laborderie J; Garrigue S; Delarche N; Jais P; Haissaguerre M; Clementy J
Pacing Clin Electrophysiol; 2009 Mar; 32 Suppl 1():S2-7. PubMed ID: 19250094
[TBL] [Abstract][Full Text] [Related]
9. [Atrial lead placement in cases of intraoperative atrial fibrillation].
Driever R; Horlitz M; Müller M; Fuchs S; Gülker H; Vetter H
Zentralbl Chir; 2003 Apr; 128(4):273-7. PubMed ID: 12700982
[TBL] [Abstract][Full Text] [Related]
10. [Arrhythmia induction during atrial pacing with atrial floating electrodes].
Izquierdo R; Pelegrín J; Sánchez A; Lacambra I; Carmona A; Rodrigo G
Rev Esp Cardiol; 2004 May; 57(5):479-81. PubMed ID: 15151783
[TBL] [Abstract][Full Text] [Related]
11. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers.
Butter C; Hartung WM; Kay GN; Willems R; Zhang G; Lang DJ; Fleck E
J Cardiovasc Electrophysiol; 2001 Oct; 12(10):1104-8. PubMed ID: 11699516
[TBL] [Abstract][Full Text] [Related]
12. The ECG lead I paradox in cardiac resynchronization therapy.
Van Gelder BM; Bracke FA
Pacing Clin Electrophysiol; 2008 Dec; 31(12):1519-21. PubMed ID: 19067802
[TBL] [Abstract][Full Text] [Related]
13. Video-assisted thoracoscopic implantation of the left ventricular pacing lead for cardiac resynchronization therapy.
Jutley RS; Waller DA; Loke I; Skehan D; Ng A; Stafford P; Chin D; Spyt TJ
Pacing Clin Electrophysiol; 2008 Jul; 31(7):812-8. PubMed ID: 18684277
[TBL] [Abstract][Full Text] [Related]
14. Wavelet-based event detection in implantable cardiac rhythm management devices.
Aström M; Olmos S; Sörnmo L
IEEE Trans Biomed Eng; 2006 Mar; 53(3):478-84. PubMed ID: 16532774
[TBL] [Abstract][Full Text] [Related]
15. Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording.
de Voogt WG; van Hemel NM; van de Bos AA; Koïstinen J; Fast JH
Europace; 2006 Nov; 8(11):950-61. PubMed ID: 17043069
[TBL] [Abstract][Full Text] [Related]
16. Alternative delivery of a 4Fr lumenless pacing lead in children.
Lapage MJ; Rhee EK
Pacing Clin Electrophysiol; 2008 May; 31(5):543-7. PubMed ID: 18439166
[TBL] [Abstract][Full Text] [Related]
17. Clinical results of far-field R-wave reduction with a short tip-ring electrode.
De Groot JR; Schroeder-Tanka JM; Visser J; Willems AR; De Voogt WG
Pacing Clin Electrophysiol; 2008 Dec; 31(12):1554-9. PubMed ID: 19067807
[TBL] [Abstract][Full Text] [Related]
18. Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
Haghjoo M; Bonakdar HR; Jorat MV; Fazelifar AF; Alizadeh A; Ojaghi-Haghjghi Z; Esmaielzadeh M; Sadr-Ameli MA
Europace; 2009 Mar; 11(3):356-63. PubMed ID: 19136489
[TBL] [Abstract][Full Text] [Related]
19. Electrical performance and automatic capture characteristics of a 3.5-mm(2) passive fixation lead during 1-year follow-up.
Lotze U; Fischer S; Höfs T; Liebetrau J; Fettin W; Scheiner J; Lang A;
Pacing Clin Electrophysiol; 2009 Aug; 32(8):1050-5. PubMed ID: 19659625
[TBL] [Abstract][Full Text] [Related]
20. Effects of different atrial pacing modes evaluated by intracardiac signal-averaged ECG.
Kutarski A; Głowniak A; Szcześniak D; Ruciński P
Cardiol J; 2008; 15(2):129-42. PubMed ID: 18651397
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]