These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 18834836)

  • 1. Central venous oxygen saturation: is it time to find its clinical applications?
    Solares G; Gomez-Fleitas M
    J Cardiothorac Vasc Anesth; 2009 Apr; 23(2):272-3. PubMed ID: 18834836
    [No Abstract]   [Full Text] [Related]  

  • 2. Comparison of central venous to mixed venous oxygen saturation in patients with low cardiac index and filling pressures after coronary artery surgery.
    Yazigi A; El Khoury C; Jebara S; Haddad F; Hayeck G; Sleilaty G
    J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):77-83. PubMed ID: 18249335
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous monitoring of central venous oxygen saturation (Pediasat) in pediatric patients undergoing cardiac surgery: a validation study of a new technology.
    Ranucci M; Isgrò G; De La Torre T; Romitti F; De Benedetti D; Carlucci C; Kandil H; Ballotta A
    J Cardiothorac Vasc Anesth; 2008 Dec; 22(6):847-52. PubMed ID: 18834840
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Venous oximetry: physiology and therapeutic implications].
    Blasco V; Leone M; Textoris J; Visintini P; Albanèse J; Martin C
    Ann Fr Anesth Reanim; 2008 Jan; 27(1):74-82. PubMed ID: 18079088
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Regional differences in tissue oxygenation during cardiopulmonary bypass for correction of congenital heart disease in neonates and small infants: relevance of near-infrared spectroscopy.
    Redlin M; Koster A; Huebler M; Boettcher W; Nagdyman N; Hetzer R; Kuppe H; Kuebler WM
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):962-7. PubMed ID: 18954637
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Continuous monitoring of mixed venous oxygen saturation in pediatric heart surgery].
    Fongaro A; Sorbara C; Bonato R; Rubino M; Giron GP
    Minerva Anestesiol; 1991 Dec; 57(12 Suppl):69-70. PubMed ID: 1806836
    [No Abstract]   [Full Text] [Related]  

  • 7. [Early goal-directed therapy (EDGT) using continuous central venous oxygen saturation monitoring in a patient with septic shock].
    Oyama Y; Goto K; Yamamoto S; Kusaka J; Hidaka S; Shingu C; Noguchi T
    Masui; 2008 Apr; 57(4):443-6. PubMed ID: 18416200
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Jugular bulb oxygen saturation in hypothermic circulatory arrest procedures: a possible role of continuous monitoring.
    Paino R; Milazzo F
    J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):172-3. PubMed ID: 18249358
    [No Abstract]   [Full Text] [Related]  

  • 9. Central venous oxygen saturation cannot replace mixed venous saturation in patients undergoing cardiac surgery.
    Lorentzen AG; Lindskov C; Sloth E; Jakobsen CJ
    J Cardiothorac Vasc Anesth; 2008 Dec; 22(6):853-7. PubMed ID: 18834841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pro: all cardiac surgical patients should have intraoperative cerebral oxygenation monitoring.
    Edmonds HL
    J Cardiothorac Vasc Anesth; 2006 Jun; 20(3):445-9. PubMed ID: 16750751
    [No Abstract]   [Full Text] [Related]  

  • 11. Con: all cardiac surgical patients should not have intraoperative cerebral oxygenation monitoring.
    Davies LK; Janelle GM
    J Cardiothorac Vasc Anesth; 2006 Jun; 20(3):450-5. PubMed ID: 16750752
    [No Abstract]   [Full Text] [Related]  

  • 12. Does use of intra-operative cerebral regional oxygen saturation monitoring during cardiac surgery lead to improved clinical outcomes?
    Vohra HA; Modi A; Ohri SK
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):318-22. PubMed ID: 19447799
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Continuous monitoring of mixed venous oxygen saturation: physiology, clinical utility, indications].
    Putterman C
    Harefuah; 1990 Aug; 119(3-4):95-9. PubMed ID: 2227679
    [No Abstract]   [Full Text] [Related]  

  • 14. [Continuous monitoring of mixed venous saturation during mechanical ventricular assistance in heart surgery].
    Giordano F; Bertolissi M; De Monte A; Muzzi R; Peressutti R; Tosolini L
    Minerva Anestesiol; 1991 Dec; 57(12 Suppl):179-81. PubMed ID: 1806828
    [No Abstract]   [Full Text] [Related]  

  • 15. [Practical experience in monitoring the oxygen saturation of central venous blood in pediatric anesthesia-resuscitation].
    Berg EA; Barbotin-Larrieu F; Laguenie G; Mathey C; Egu JF; Goutail-Flaud F; Saint-Maurice C
    Cah Anesthesiol; 1993; 41(1):29-37. PubMed ID: 8490745
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Recent advances in application of cerebral oximetry in adult cardiovascular surgery.
    Fischer GW
    Semin Cardiothorac Vasc Anesth; 2008 Mar; 12(1):60-9. PubMed ID: 18397905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Con: all cardiac surgical patients should not have intraoperative cerebral oxygenation monitoring.
    Muehlschlegel S; Lobato EB
    J Cardiothorac Vasc Anesth; 2006 Aug; 20(4):613-5. PubMed ID: 16884999
    [No Abstract]   [Full Text] [Related]  

  • 18. [Central venous oxygen saturation monitoring was useful in two cases of hepatectomy with massive bleeding].
    Kawaguchi Y; Kushikata T; Kitayama M; Hirota K
    Masui; 2006 Dec; 55(12):1502-5. PubMed ID: 17190326
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation.
    el-Masry A; Mukhtar AM; el-Sherbeny AM; Fathy M; el-Meteini M
    Anaesthesia; 2009 Apr; 64(4):378-82. PubMed ID: 19317701
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The monitoring of venous saturations of oxygen in children with congenitally malformed hearts.
    Martin J; Shekerdemian LS
    Cardiol Young; 2009 Feb; 19(1):34-9. PubMed ID: 19154627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.