These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 18835262)

  • 1. Comparison of 10% coefficient of variation and 99th percentile cutoff of troponin I in serum and heparinized plasma using Access 2 and DxI 800.
    Song S; Suh B; Lee SG; Kim JH; Kwon OH
    Clin Chim Acta; 2009 Jan; 399(1-2):117-8. PubMed ID: 18835262
    [No Abstract]   [Full Text] [Related]  

  • 2. Performance characteristics of five cardiac Troponin I assays.
    La'ulu SL; Roberts WL
    Clin Chim Acta; 2010 Aug; 411(15-16):1095-101. PubMed ID: 20398643
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Decision limit for troponin I on ADVIA:Centaur and evaluation of the analytical precision at low concentrations.
    Fortunato A; Giavarina D
    Clin Lab; 2003; 49(5-6):251-3. PubMed ID: 15285182
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia.
    Venge P; Johnston N; Lindahl B; James S
    J Am Coll Cardiol; 2009 Sep; 54(13):1165-72. PubMed ID: 19761938
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of Access hsTnI 99th percentiles upper reference limits following IFCC recommendations.
    Di Pietro M; Dipalo M; Rocchi MBL; Musa R; Avanzini P; Gnocchi C; Anelli MC; Aloe R
    Clin Chim Acta; 2019 May; 492():26-28. PubMed ID: 30711523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The comparative analytical performance of four troponin I assays at low concentration.
    Koerbin G; Tate JR; Potter JM; Hickman PE
    Ann Clin Biochem; 2005 Jan; 42(Pt 1):19-23. PubMed ID: 15802028
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prevention of preanalytical false-positive increases of cardiac troponin I on the Unicel DxI 800 analyzer.
    Hejl CG; Astier HT; Ramirez JM
    Clin Chem Lab Med; 2008; 46(12):1789-90. PubMed ID: 19055457
    [No Abstract]   [Full Text] [Related]  

  • 8. [Analytical false-positive increases and cardiac troponin I: what is the best sample?].
    Grenier A
    Ann Biol Clin (Paris); 2009; 67(1):118-20. PubMed ID: 19278053
    [No Abstract]   [Full Text] [Related]  

  • 9. Alteration and significance of serum cardiac troponin I and cystatin C in preeclampsia.
    Yang X; Wang H; Wang Z; Dong M
    Clin Chim Acta; 2006 Dec; 374(1-2):168-9. PubMed ID: 16914129
    [No Abstract]   [Full Text] [Related]  

  • 10. The determination of the 99th centile level for troponin assays in an Australian reference population.
    Tate JR; Ferguson W; Bais R; Kostner K; Marwick T; Carter A
    Ann Clin Biochem; 2008 May; 45(Pt 3):275-88. PubMed ID: 18482916
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac troponin cutoffs: the importance of assay sensitivity and the patient population.
    Kavsak PA; Dhesy-Thind S
    J Clin Oncol; 2011 Mar; 29(7):e177; author reply e178-9. PubMed ID: 21189389
    [No Abstract]   [Full Text] [Related]  

  • 12. Creatine-kinase MB mass: age and sex-associated reference limits in two different platforms that use the same method.
    Zaninotto M; Mion MM; Novello E; Delprete E; Moretti M; Plebani M
    Clin Chim Acta; 2009 Mar; 401(1-2):162-4. PubMed ID: 19101529
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assay-related issues in the measurement of cardiac troponins.
    Panteghini M
    Clin Chim Acta; 2009 Apr; 402(1-2):88-93. PubMed ID: 19168041
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Interpretation of high sensitivity cardiac troponin I results: reference to biological variability in patients who present to the emergency room with chest pain: case report series.
    Wu AH
    Clin Chim Acta; 2009 Mar; 401(1-2):170-4. PubMed ID: 19135041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved sensitivity of point of care troponin I values using reporting to below 99th percentile of normals. Schneider HG et al.
    Wilgen U; Pretorius CJ; Ungerer JP
    Clin Biochem; 2013 Nov; 46(16-17):1774-5. PubMed ID: 23872257
    [No Abstract]   [Full Text] [Related]  

  • 16. Troponin I concentrations in heparinized plasma and serum differ when measured with the Advia Centaur TnI-Ultra assay.
    van de Kerkhof D; Peters B; Scharnhorst V
    Scand J Clin Lab Invest; 2008; 68(7):513-5. PubMed ID: 19378420
    [No Abstract]   [Full Text] [Related]  

  • 17. Cardiac troponin I seems to be superior to cardiac troponin T in the early detection of cardiac injury associated with anthracycline treatment.
    Horacek JM; Pudil R; Tichy M; Jebavy L; Strasova A; Ulrychova M; Zak P; Maly J
    Onkologie; 2008 Oct; 31(10):559-60. PubMed ID: 18854658
    [No Abstract]   [Full Text] [Related]  

  • 18. Changes in troponin kits preclude meaningful collection of data on population 99th percentiles.
    Hickman PE; Miller E; Koerbin G; Potter JM
    Ann Clin Biochem; 2004 Nov; 41(Pt 6):503-4. PubMed ID: 15588447
    [No Abstract]   [Full Text] [Related]  

  • 19. Is there a clinical need to measure the cardiac troponin I concentration before major abdominal surgery in high-risk patients?
    Boccara G; Coriat P; Colson P
    Eur J Anaesthesiol; 2006 Feb; 23(2):173-5. PubMed ID: 16426474
    [No Abstract]   [Full Text] [Related]  

  • 20. The 99th percentile values of six cardiac troponin assays established for a reference population using strict selection criteria.
    Ko DH; Jeong TD; Cho EJ; Lim J; Ji M; Lee K; Lee W; Yun YM; Chun S; Song J; Kwon KC; Min WK
    Clin Chim Acta; 2017 Jan; 464():1-5. PubMed ID: 27823950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.