BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 18841855)

  • 21. An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams.
    Hill R; Mo Z; Haque M; Baldock C
    Med Phys; 2009 Sep; 36(9):3971-81. PubMed ID: 19810470
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Sci-Fri PM: Planning-10: The replacement correction factors for cylindrical chambers in megavoltage beams.
    Wang L; Rogers D
    Med Phys; 2008 Jul; 35(7Part3):3414. PubMed ID: 28512897
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
    Saiful Huq M; Song H; Andreo P; Houser CJ
    Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system.
    Sempau J; Andreo P; Aldana J; Mazurier J; Salvat F
    Phys Med Biol; 2004 Sep; 49(18):4427-44. PubMed ID: 15509075
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Monte Carlo simulated beam quality and perturbation correction factors for ionization chambers in monoenergetic proton beams.
    Kretschmer J; Dulkys A; Brodbek L; Stelljes TS; Looe HK; Poppe B
    Med Phys; 2020 Nov; 47(11):5890-5905. PubMed ID: 32989779
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Calibration of parallel-plate chambers: resolution of several problems by using Monte Carlo calculations.
    Rogers DW
    Med Phys; 1992; 19(4):889-99. PubMed ID: 1518477
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Beam quality corrections for parallel-plate ion chambers in electron reference dosimetry.
    Zink K; Wulff J
    Phys Med Biol; 2012 Apr; 57(7):1831-54. PubMed ID: 22411097
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets.
    Capote R; Sánchez-Doblado F; Leal A; Lagares JI; Arráns R; Hartmann GH
    Med Phys; 2004 Sep; 31(9):2416-22. PubMed ID: 15487721
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Experimental investigation of the effective point of measurement for plane-parallel chambers used in electron beam dosimetry.
    Yasui K; Nakajima Y; Suda Y; Arai Y; Takizawa T; Sakai K; Fujita Y
    J Appl Clin Med Phys; 2023 Jul; 24(7):e14059. PubMed ID: 37307247
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Determination of overall perturbation factors for plane-parallel ionization chambers in electron beams.
    Araki F; Shirakawa Y; Ikeda R; Shimonobou T; Moribe N; Takada T; Takahashi M; Oura H; Matoba M
    Igaku Butsuri; 2000; 20(2):95-103. PubMed ID: 12764248
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of ICRU report 90 recommendations on Monte Carlo calculated k
    Kawachi T; Saitoh H; Katayose T; Tohyama N; Miyasaka R; Cho SY; Iwase T; Hara R
    Med Phys; 2019 Nov; 46(11):5185-5194. PubMed ID: 31386762
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams.
    Zink K; Czarnecki D; Looe HK; von Voigts-Rhetz P; Harder D
    Med Phys; 2014 Nov; 41(11):111707. PubMed ID: 25370621
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Sci-Thur PM: YIS - 07: Monte Carlo simulations to obtain several parameters required for electron beam dosimetry.
    Muir B; Rogers D; McEwen M
    Med Phys; 2012 Jul; 39(7Part2):4623. PubMed ID: 28516522
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams: an extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No. 39.
    Almond PR; Attix FH; Humphries LJ; Kubo H; Nath R; Goetsch S; Rogers DW
    Med Phys; 1994 Aug; 21(8):1251-60. PubMed ID: 7799867
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparing the dosimeter-specific corrections for influence quantities of some parallel-plate ionization chambers in conventional electron beam dosimetry.
    Baghani HR; Robatjazi M; Andreoli S
    Appl Radiat Isot; 2022 Jan; 179():110031. PubMed ID: 34801928
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new approach to electron-beam reference dosimetry.
    Rogers DW
    Med Phys; 1998 Mar; 25(3):310-20. PubMed ID: 9547498
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental determination of the overall perturbation factor for the NACP chamber in electron beams for dmax < d < or = d80.
    Reft CS; Kuchnir FT
    Phys Med Biol; 2001 Feb; 46(2):N49-55. PubMed ID: 11229741
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Verification of absorbed doses determined with thimble and parallel-plate ionization chambers in clinical electron beams using ferrous sulphate dosimetry.
    Van der Plaetsen A; Seuntjens J; Thierens H; Vynckier S
    Med Phys; 1994 Jan; 21(1):37-44. PubMed ID: 8164587
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monte Carlo-calculated beam quality and perturbation correction factors validated against experiments for Farmer and Markus type ionization chambers in therapeutic carbon-ion beams.
    Urago Y; Sakama M; Sakata D; Fukuda S; Katayose T; Chang W
    Phys Med Biol; 2023 Sep; 68(18):. PubMed ID: 37579752
    [No Abstract]   [Full Text] [Related]  

  • 40. Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation.
    Wang LL; Rogers DW
    Med Phys; 2009 Jun; 36(6):2034-42. PubMed ID: 19610292
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.