116 related articles for article (PubMed ID: 18843456)
1. Novel method to evaluate femoral head penetration in the polyethylene liner after total hip arthroplasty: three-dimensional evaluation on standing radiographs.
Hamaji H; Yamamoto S; Ishibashi H; Anamizu Y
J Orthop Sci; 2008 Sep; 13(5):425-32. PubMed ID: 18843456
[TBL] [Abstract][Full Text] [Related]
2. Standing versus supine radiographs to evaluate femoral head penetration in the polyethylene liner after total hip arthroplasty.
Maruyama M; Tensho K; Wakabayashi S; Hisa K
J Arthroplasty; 2014 Dec; 29(12):2415-9. PubMed ID: 24742717
[TBL] [Abstract][Full Text] [Related]
3. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in.
Sychterz CJ; Engh CA; Yang A; Engh CA
J Bone Joint Surg Am; 1999 Jun; 81(6):821-30. PubMed ID: 10391547
[TBL] [Abstract][Full Text] [Related]
4. Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear.
Sychterz CJ; Yang AM; McAuley JP; Engh CA
Clin Orthop Relat Res; 1999 Aug; (365):117-23. PubMed ID: 10627695
[TBL] [Abstract][Full Text] [Related]
5. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time.
Sychterz CJ; Engh CA; Shah N; Engh CA
J Bone Joint Surg Am; 1997 Jul; 79(7):1040-6. PubMed ID: 9234880
[TBL] [Abstract][Full Text] [Related]
6. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.
McCalden RW; MacDonald SJ; Rorabeck CH; Bourne RB; Chess DG; Charron KD
J Bone Joint Surg Am; 2009 Apr; 91(4):773-82. PubMed ID: 19339560
[TBL] [Abstract][Full Text] [Related]
7. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years.
Dorr LD; Wan Z; Shahrdar C; Sirianni L; Boutary M; Yun A
J Bone Joint Surg Am; 2005 Aug; 87(8):1816-21. PubMed ID: 16085624
[TBL] [Abstract][Full Text] [Related]
8. Standing versus supine radiographs in RSA evaluation of femoral head penetration.
Bragdon CR; Thanner J; Greene ME; Malchau H; Digas G; Harris WH; Kärrholm J
Clin Orthop Relat Res; 2006 Jul; 448():46-51. PubMed ID: 16826095
[TBL] [Abstract][Full Text] [Related]
9. The effect of weight-bearing on the radiographic measurement of the position of the femoral head after total hip arthroplasty.
Moore KD; Barrack RL; Sychterz CJ; Sawhney J; Yang AM; Engh CA
J Bone Joint Surg Am; 2000 Jan; 82(1):62-9. PubMed ID: 10653085
[TBL] [Abstract][Full Text] [Related]
10. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis.
Digas G; Kärrholm J; Thanner J; Malchau H; Herberts P
Clin Orthop Relat Res; 2004 Dec; (429):6-16. PubMed ID: 15577460
[TBL] [Abstract][Full Text] [Related]
11. The influence of early radiolucent lines appearing on femoral head penetration into HXLPE cemented sockets.
Morita D; Seki T; Higuchi Y; Takegami Y; Amano T; Ishiguro N
Hip Int; 2018 Jul; 28(4):369-374. PubMed ID: 29707984
[TBL] [Abstract][Full Text] [Related]
12. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.
Digas G
Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty.
Collier MB; Kraay MJ; Rimnac CM; Goldberg VM
J Bone Joint Surg Am; 2003 Dec; 85(12):2410-8. PubMed ID: 14668512
[TBL] [Abstract][Full Text] [Related]
14. Measuring the migration of the components and polyethylene wear after total hip arthroplasty: beads and specialised radiographs are not necessary.
Devane PA; Horne JG; Foley G; Stanley J
Bone Joint J; 2017 Oct; 99-B(10):1290-1297. PubMed ID: 28963149
[TBL] [Abstract][Full Text] [Related]
15. Polyethylene wear after total hip arthroplasty: the effect of a modular femoral head with an extended flange-reinforced neck.
Urquhart AG; D'Lima DD; Venn-Watson E; Colwell CW; Walker RH
J Bone Joint Surg Am; 1998 Nov; 80(11):1641-7. PubMed ID: 9840633
[TBL] [Abstract][Full Text] [Related]
16. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
[TBL] [Abstract][Full Text] [Related]
17. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.
Teeter MG; Goyal P; Yuan X; Howard JL; Lanting BA
J Arthroplasty; 2018 Jan; 33(1):263-267. PubMed ID: 28917617
[TBL] [Abstract][Full Text] [Related]
18. Early outcomes of sequentially cross-linked thin polyethylene liners with large diameter femoral heads in total hip arthroplasty.
Sayeed SA; Mont MA; Costa CR; Johnson AJ; Naziri Q; Bonutti PM; Delanois RE
Bull NYU Hosp Jt Dis; 2011; 69 Suppl 1():S90-4. PubMed ID: 22035492
[TBL] [Abstract][Full Text] [Related]
19. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
Kim YH
J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
[TBL] [Abstract][Full Text] [Related]
20. Two-year radiostereometric analysis evaluation of femoral head penetration in a challenging population of young total hip arthroplasty patients.
Ayers DC; Hays PL; Drew JM; Eskander MS; Osuch D; Bragdon CR
J Arthroplasty; 2009 Sep; 24(6 Suppl):9-14. PubMed ID: 19698909
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]