BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 18849636)

  • 41. Microperimetry in patients with central serous retinopathy.
    Toonen F; Remky A; Janssen V; Wolf S; Reim M
    Ger J Ophthalmol; 1995 Sep; 4(5):311-4. PubMed ID: 7496344
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Contrasting blue-on-yellow with white-on-white visual fields: Roles of visual adaptation for healthy peri- or postmenopausal women younger than 70 years of age.
    Eisner A; Toomey MD; Incognito LJ; O'malley JP; Samples JR
    Invest Ophthalmol Vis Sci; 2006 Dec; 47(12):5605-14. PubMed ID: 17122155
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Age-dependent normative values for differential luminance sensitivity in automated static perimetry using the Octopus 101.
    Hermann A; Paetzold J; Vonthein R; Krapp E; Rauscher S; Schiefer U
    Acta Ophthalmol; 2008 Jun; 86(4):446-55. PubMed ID: 18070224
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Fixation pattern in healthy subjects during microperimetry with the scanning laser ophthalmoscope.
    Källmark FP; Ygge J
    Med Sci Monit; 2008 Jun; 14(6):CR311-315. PubMed ID: 18509274
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Compensation for light loss resulting from filtering by macular pigment: relation to the S-cone pathway.
    Stringham JM; Hammond BR; Wooten BR; Snodderly DM
    Optom Vis Sci; 2006 Dec; 83(12):887-94. PubMed ID: 17164681
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Macular structure and vision of patients with macular heterotopia secondary to retinopathy of prematurity.
    Soong GP; Shapiro M; Seiple W; Szlyk JP
    Retina; 2008 Oct; 28(8):1111-6. PubMed ID: 18779718
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Normal values for fundus perimetry with the microperimeter MP1.
    Midena E; Vujosevic S; Cavarzeran F;
    Ophthalmology; 2010 Aug; 117(8):1571-6, 1576.e1. PubMed ID: 20472294
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Normative data for macular thickness by high-definition spectral-domain optical coherence tomography (spectralis).
    Grover S; Murthy RK; Brar VS; Chalam KV
    Am J Ophthalmol; 2009 Aug; 148(2):266-71. PubMed ID: 19427616
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Eccentric fixation in Stargardt's disease assessed by Tübingen perimetry.
    Messias A; Reinhard J; Velasco e Cruz AA; Dietz K; MacKeben M; Trauzettel-Klosinski S
    Invest Ophthalmol Vis Sci; 2007 Dec; 48(12):5815-22. PubMed ID: 18055836
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Visual rehabilitation using microperimetric acoustic biofeedback training in individuals with central scotoma.
    Ratra D; Gopalakrishnan S; Dalan D; Ratra V; Damkondwar D; Laxmi G
    Clin Exp Optom; 2019 Mar; 102(2):172-179. PubMed ID: 30253443
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Adaptation mechanisms, eccentricity profiles, and clinical implementation of red-on-white perimetry.
    Zele AJ; Dang TM; O'Loughlin RK; Guymer RH; Harper A; Vingrys AJ
    Optom Vis Sci; 2008 May; 85(5):309-17. PubMed ID: 18451735
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Fixation Characteristics of Severe Amblyopia Subtypes: Which One is Worse?
    Koylu MT; Ozge G; Kucukevcilioglu M; Mutlu FM; Ceylan OM; Akıncıoglu D; Ayyıldız O
    Semin Ophthalmol; 2017; 32(5):553-558. PubMed ID: 27191734
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Population norms for frequency doubling perimetry with uncorrected refractive error.
    Ramesh SV; George R; Soni PM; Palaniappan L; Raju P; Paul PG; Ramsathish S; Vijaya L
    Optom Vis Sci; 2007 Jun; 84(6):496-504. PubMed ID: 17568319
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Light sensitivity in central visual field].
    Wu Z; Li Y; Jiang Y
    Zhonghua Yan Ke Za Zhi; 1998 Jul; 34(4):300-3. PubMed ID: 11877214
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Enhancing performance while avoiding damage: a contribution of macular pigment.
    Stringham JM; Snodderly DM
    Invest Ophthalmol Vis Sci; 2013 Sep; 54(9):6298-306. PubMed ID: 23982840
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Intrasession repeatability of fixation stability assessment with the Nidek MP-1.
    Chen FK; Patel PJ; Xing W; Crossland MD; Bunce C; Rubin GS; Da Cruz L
    Optom Vis Sci; 2011 Jun; 88(6):742-50. PubMed ID: 21460754
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Compensation for light loss due to filtering by macular pigment: relation to hue cancellation.
    Stringham JM; Hammond BR
    Ophthalmic Physiol Opt; 2007 May; 27(3):232-7. PubMed ID: 17470235
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Improving detection of mild loss of retinal light increment sensitivity at the posterior pole with the microperimeter MP1.
    Bowl W; Lorenz B; Jäger M; Friedburg C
    Invest Ophthalmol Vis Sci; 2013 Jul; 54(7):4666-74. PubMed ID: 23716630
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Retinal sensitivity in healthy Indians using microperimeter.
    Gella L; Nittala MG; Raman R
    Indian J Ophthalmol; 2014 Mar; 62(3):284-6. PubMed ID: 23619501
    [TBL] [Abstract][Full Text] [Related]  

  • 60. On age-related norms of the visual field.
    Iwase A; Kitazawa Y; Ohno Y
    Jpn J Ophthalmol; 1988; 32(4):429-37. PubMed ID: 3236565
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.