These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 1885436)

  • 1. Confidence intervals of respiratory mechanical properties derived from transfer impedance.
    Rotger M; Peslin R; Oostveen E; Gallina C
    J Appl Physiol (1985); 1991 Jun; 70(6):2432-8. PubMed ID: 1885436
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance.
    Lutchen KR; Everett JR; Jackson AC
    J Appl Physiol (1985); 1993 Mar; 74(3):1089-99. PubMed ID: 8482647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow and volume dependence of respiratory mechanical properties studied by forced oscillation.
    Oostveen E; Peslin R; Gallina C; Zwart A
    J Appl Physiol (1985); 1989 Dec; 67(6):2212-8. PubMed ID: 2606826
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Density dependence of respiratory input and transfer impedances in humans.
    Rotger M; Peslin R; Duvivier C; Navajas D; Gallina C
    J Appl Physiol (1985); 1988 Aug; 65(2):928-33. PubMed ID: 3170438
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Density dependence of respiratory system impedances between 5 and 320 Hz in humans.
    Jackson AC; Giurdanella CA; Dorkin HL
    J Appl Physiol (1985); 1989 Dec; 67(6):2323-30. PubMed ID: 2606839
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal frequency range to analyze respiratory transfer impedance with six-element model.
    Tomalak W; Peslin R; Duvivier C; Gallina C
    J Appl Physiol (1985); 1993 Dec; 75(6):2656-64. PubMed ID: 8125886
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiratory transfer impedance and derived mechanical properties of conscious rats.
    Oostveen E; Zwart A; Peslin R; Duvivier C
    J Appl Physiol (1985); 1992 Oct; 73(4):1598-607. PubMed ID: 1447110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Airways impedance during single breaths of foreign gases.
    Oostveen E; Peslin R; Duvivier C; Rotger M; Mead J
    J Appl Physiol (1985); 1991 Nov; 71(5):1813-21. PubMed ID: 1761478
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physiological basis for resonant frequencies in respiratory system impedances in dogs.
    Jackson AC; Lutchen KR
    J Appl Physiol (1985); 1991 Mar; 70(3):1051-8. PubMed ID: 2032970
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interpretation of respiratory input impedance in healthy infants.
    Jackson AC; Neff KM; Dorkin HL; Lutchen KR
    Pediatr Pulmonol; 1996 Dec; 22(6):364-75. PubMed ID: 9016470
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inability to separate airway from tissue properties by use of human respiratory input impedance.
    Lutchen KR; Giurdanella CA; Jackson AC
    J Appl Physiol (1985); 1990 Jun; 68(6):2403-12. PubMed ID: 2384422
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Four and six parameter models of forced random noise respiratory impedance in normals.
    Lorino H; Mariette C; Lorino AM; Harf A
    Eur Respir J; 1989 Oct; 2(9):874-82. PubMed ID: 2806515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of heterogeneities on the partitioning of airway and tissue properties in normal mice.
    Ito S; Lutchen KR; Suki B
    J Appl Physiol (1985); 2007 Mar; 102(3):859-69. PubMed ID: 17138833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Respiratory input and transfer mechanical impedances in patients with chronic obstructive pulmonary disease.
    Ying Y; Peslin R; Duvivier C; Gallina C; Felicio da Silva J
    Eur Respir J; 1990 Nov; 3(10):1186-92. PubMed ID: 2090482
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Human lung impedance from spontaneous breathing frequencies to 32 Hz.
    Farré R; Peslin R; Rotger M; Navajas D
    J Appl Physiol (1985); 1994 Mar; 76(3):1176-83. PubMed ID: 8005861
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Airway and tissue mechanics during physiological breathing and bronchoconstriction in dogs.
    Lutchen KR; Suki B; Zhang Q; Peták F; Daróczy B; Hantos Z
    J Appl Physiol (1985); 1994 Jul; 77(1):373-85. PubMed ID: 7961260
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modeling of low-frequency pulmonary impedance in dogs.
    Hantos Z; Daróczy B; Csendes T; Suki B; Nagy S
    J Appl Physiol (1985); 1990 Mar; 68(3):849-60. PubMed ID: 2341352
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Separation of airway and tissue properties by transfer respiratory impedance and thoracic gas volume in reversible airway obstruction.
    Marchal F; Bouaziz N; Baeyert C; Gallina C; Duvivier C; Peslin R
    Eur Respir J; 1996 Feb; 9(2):253-61. PubMed ID: 8777961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory mechanics of horses measured by conventional and forced oscillation techniques.
    Young SS; Tesarowski D
    J Appl Physiol (1985); 1994 Jun; 76(6):2467-72. PubMed ID: 7928872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lung tissue and airway impedances during pulmonary edema in normal range of breathing.
    Barnas GM; Sprung J; Kahn R; Delaney PA; Agarwal M
    J Appl Physiol (1985); 1995 May; 78(5):1889-97. PubMed ID: 7649927
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.