  • 1. Hydrogen sensor based on Au and YSZ/HgO/Hg electrode for in situ measurement of dissolved H2 in high-temperature and -pressure fluids.
    Zhang RH; Hu SM; Zhang XT; Wang Y
    Anal Chem; 2008 Nov; 80(22):8807-13. PubMed ID: 18855413
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Zr/ZrO2 sensors for in situ measurement of pH in high-temperature and -pressure aqueous solutions.
    Zhang RH; Zhang XT; Hu SM
    Anal Chem; 2008 Apr; 80(8):2982-7. PubMed ID: 18345645
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and characterization of Au-YSZ surface plasmon resonance based sensing materials: high temperature detection of CO.
    Sirinakis G; Siddique R; Manning I; Rogers PH; Carpenter MA
    J Phys Chem B; 2006 Jul; 110(27):13508-11. PubMed ID: 16821877
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In situ measurement of pH and dissolved H2 in mid-ocean ridge hydrothermal fluids at elevated temperatures and pressures.
    Ding K; Seyfried WE
    Chem Rev; 2007 Feb; 107(2):601-22. PubMed ID: 17300142
    [No Abstract]   [Full Text] [Related]  

  • 5. Construction of sensitive and selective zirconia-based CO sensors using ZnCr2O(4)-based sensing electrodes.
    Fujio Y; Plashnitsa VV; Breedon M; Miura N
    Langmuir; 2012 Jan; 28(2):1638-45. PubMed ID: 22142329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Synchrotron x-ray spectroscopy of EuHNO3 aqueous solutions at high temperatures and pressures and Nb-bearing silicate melt phases coexisting with hydrothermal fluids using a modified hydrothermal diamond anvil cell and rail assembly.
    Mayanovic RA; Anderson AJ; Bassett WA; Chou IM
    Rev Sci Instrum; 2007 May; 78(5):053904. PubMed ID: 17552838
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In situ measurement of pH under high pressure.
    Samaranayake CP; Sastry SK
    J Phys Chem B; 2010 Oct; 114(42):13326-32. PubMed ID: 20886865
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous measurement of dissolved H2 in an anaerobic reactor using a new hydrogen/air fuel cell detector.
    Pauss A; Samson R; Guiot S; Beauchemin C
    Biotechnol Bioeng; 1990 Mar; 35(5):492-501. PubMed ID: 18592542
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Structurally integrated organic light emitting device-based sensors for gas phase and dissolved oxygen.
    Shinar R; Zhou Z; Choudhury B; Shinar J
    Anal Chim Acta; 2006 May; 568(1-2):190-9. PubMed ID: 17761260
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Viscosity measurements of water at high temperatures and pressures using dynamic light scattering.
    Deguchi S; Ghosh SK; Alargova RG; Tsujii K
    J Phys Chem B; 2006 Sep; 110(37):18358-62. PubMed ID: 16970458
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High sensitivity SnO2 single-nanorod sensors for the detection of H2 gas at low temperature.
    Huang H; Lee YC; Tan OK; Zhou W; Peng N; Zhang Q
    Nanotechnology; 2009 Mar; 20(11):115501. PubMed ID: 19420439
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Highly sensitive electrochemical sensor for mercury(II) ions by using a mercury-specific oligonucleotide probe and gold nanoparticle-based amplification.
    Zhu Z; Su Y; Li J; Li D; Zhang J; Song S; Zhao Y; Li G; Fan C
    Anal Chem; 2009 Sep; 81(18):7660-6. PubMed ID: 19691296
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stabilization of sensing performance for mixed-potential-type zirconia-based hydrocarbon sensor.
    Fujio Y; Plashnitsa VV; Elumalai P; Miura N
    Talanta; 2011 Jul; 85(1):575-81. PubMed ID: 21645744
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Concentration-specific hydrogen sensing behavior in monosized Pd nanoparticle layers.
    Khanuja M; Kala S; Mehta BR; Kruis FE
    Nanotechnology; 2009 Jan; 20(1):015502. PubMed ID: 19417253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a nuclear magnetic resonance system for in situ analysis of hydrogen storage materials under high pressures and temperatures.
    Hashimoto S; Noda Y; Maekawa H; Takamura H; Fujito T; Moriya J; Ikeda T
    Rev Sci Instrum; 2010 Oct; 81(10):104101. PubMed ID: 21034100
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Electrode Configuration on Nitric Oxide Gas Sensor Behavior.
    Cui L; Murray EP
    Sensors (Basel); 2015 Sep; 15(9):24573-84. PubMed ID: 26404312
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standard partial molar volumes of some aqueous alkanolamines and alkoxyamines at temperatures up to 325 degrees C: functional group additivity in polar organic solutes under hydrothermal conditions.
    Bulemela E; Tremaine PR
    J Phys Chem B; 2008 May; 112(18):5626-45. PubMed ID: 18412415
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dissolved oxygen measurements in aquatic environments: the effects of changing temperature and pressure on three sensor technologies.
    Markfort CD; Hondzo M
    J Environ Qual; 2009; 38(4):1766-74. PubMed ID: 19549954
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ozone- and thermally activated films of palladium monolayer-protected clusters for chemiresistive hydrogen sensing.
    Ibañez FJ; Zamborini FP
    Langmuir; 2006 Nov; 22(23):9789-96. PubMed ID: 17073513
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a continuous-flow reactor for in situ x-ray absorption spectroscopy of solids in supercritical fluids.
    Dreher M; De Boni E; Nachtegaal M; Wambach J; Vogel F
    Rev Sci Instrum; 2012 May; 83(5):054101. PubMed ID: 22667633
    [TBL] [Abstract][Full Text] [Related]  