These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 18929322)

  • 1. The Sprint Fidelis lead fracture story: what do we really know and where do we go from here?
    Ellenbogen KA; Wood MA; Swerdlow CD
    Heart Rhythm; 2008 Oct; 5(10):1380-1. PubMed ID: 18929322
    [No Abstract]   [Full Text] [Related]  

  • 2. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?
    Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M
    Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Relationship between Sprint Fidelis leads and patient mortality.
    Maytin M; Epstein LM
    J Am Coll Cardiol; 2012 Jan; 59(2):193-4. PubMed ID: 22222084
    [No Abstract]   [Full Text] [Related]  

  • 8. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lead electrical parameters may not predict integrity of the Sprint Fidelis ICD lead.
    Maytin M; Epstein LM
    Heart Rhythm; 2012 Sep; 9(9):1446-51. PubMed ID: 22537883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mortality risk of Fidelis management.
    Faddis MN
    J Am Coll Cardiol; 2011 Jul; 58(3):284-5. PubMed ID: 21737020
    [No Abstract]   [Full Text] [Related]  

  • 12. Impact of implanted recalled sprint Fidelis lead on patient mortality.
    Morrison TB; Friedman PA; Kallinen LM; Hodge DO; Crusan D; Kumar K; Hayes DL; Rea RF; Hauser RG
    J Am Coll Cardiol; 2011 Jul; 58(3):278-83. PubMed ID: 21737019
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Riata story-where are we now?
    Henrikson CA
    Heart Rhythm; 2012 May; 9(5):750-1. PubMed ID: 22248757
    [No Abstract]   [Full Text] [Related]  

  • 15. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
    Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD
    Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fatal complication of ICD therapy due to lead failure.
    Theuns DA; Szili-Torok T; Jordaens LJ
    J Cardiovasc Electrophysiol; 2008 Jul; 19(7):E48. PubMed ID: 18554196
    [No Abstract]   [Full Text] [Related]  

  • 17. Defibrillation testing can reveal 'concealed' lead fracture.
    Bun SS; Duytschaever M; Tavernier R
    Europace; 2013 Jan; 15(1):54. PubMed ID: 22719061
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of Sprint Fidelis and Riata defibrillator lead failure rates.
    Fazal IA; Shepherd EJ; Tynan M; Plummer CJ; McComb JM
    Int J Cardiol; 2013 Sep; 168(2):848-52. PubMed ID: 23138013
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biventricular implantable cardioverter defibrillator right ventricle pace-sense ring electrode failure: lead switch fix.
    Venkataraman G; Moore H; Karasik P; Singh S; Fletcher R
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):899-903. PubMed ID: 18684289
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.