These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 18948240)

  • 1. Beating-heart coronary artery bypass grafting using a miniaturized extracorporeal circulation system.
    Reber D; Fritz M; Tossios P; Buchwald D; Lindstaedt M; Klak K; Marks P; Laczkovics A
    Heart Surg Forum; 2008; 11(5):E276-80. PubMed ID: 18948240
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Beating-heart coronary artery bypass grafting with miniaturized cardiopulmonary bypass results in a more complete revascularization when compared to off-pump grafting.
    Reber D; Brouwer R; Buchwald D; Fritz M; Germing A; Lindstaedt M; Klak K; Laczkovics A
    Artif Organs; 2010 Mar; 34(3):179-84. PubMed ID: 20447041
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On-pump beating-heart coronary artery bypass grafting after acute myocardial infarction has lower mortality and morbidity.
    Miyahara K; Matsuura A; Takemura H; Saito S; Sawaki S; Yoshioka T; Ito H
    J Thorac Cardiovasc Surg; 2008 Mar; 135(3):521-6. PubMed ID: 18329463
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Miniaturized extracorporeal circulation vs. off-pump coronary artery bypass grafting: what the evidence shows?
    Harling L; Punjabi PP; Athanasiou T
    Perfusion; 2011 Sep; 26 Suppl 1():40-7. PubMed ID: 21933821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robotic-assisted coronary artery bypass on a beating heart: initial experience and implications for the future.
    Turner WF; Sloan JH
    Ann Thorac Surg; 2006 Sep; 82(3):790-4; discussion 794. PubMed ID: 16928484
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimal extracorporeal circulation and off-pump compared to conventional cardiopulmonary bypass in coronary surgery.
    Panday GF; Fischer S; Bauer A; Metz D; Schubel J; El Shouki N; Eberle T; Hausmann H
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):832-6. PubMed ID: 19671581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?
    Remadi JP; Marticho P; Butoi I; Rakotoarivelo Z; Trojette F; Benamar A; Beloucif S; Foure D; Poulain HJ
    Ann Thorac Surg; 2004 Jun; 77(6):2172-5; discussion 2176. PubMed ID: 15172290
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using decision-analysis and meta-analysis to predict coronary artery bypass surgical outcomes - a model for comparing off-pump surgery to miniaturized cardiopulmonary bypass circuits.
    Sistino J
    Perfusion; 2008 Sep; 23(5):255-60. PubMed ID: 19346262
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A trial to improve operative results of coronary artery bypass grafting (CABG); off-pump CABG (OPCAB) as standard procedure].
    Watanabe Y
    Kyobu Geka; 2009 Jan; 62(1):24-7. PubMed ID: 19195182
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Totally minimized extracorporeal circulation: an important benefit for coronary artery bypass grafting in Jehovah's witnesses.
    Vaislic C; Bical O; Farge C; Gaillard D; Ponzio O; Ollivier Y; Abdelmoumen Y; Robine B; Souffrant G; Bouharaoua T
    Heart Surg Forum; 2003; 6(5):307-10. PubMed ID: 14721799
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Myocardial revascularization with miniaturized extracorporeal circulation versus off pump: Evaluation of systemic and myocardial inflammatory response in a prospective randomized study.
    Formica F; Broccolo F; Martino A; Sciucchetti J; Giordano V; Avalli L; Radaelli G; Ferro O; Corti F; Cocuzza C; Paolini G
    J Thorac Cardiovasc Surg; 2009 May; 137(5):1206-12. PubMed ID: 19379993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In hospital outcome of patients undergoing coronary endarterectomy: comparison between off-pump vs on pump CABG.
    Hussain I; Ghaffar A; Shahbaz A; Sami W; Muhammad A; Seher N; Wahab F; Khan JS
    J Ayub Med Coll Abbottabad; 2008; 20(1):31-7. PubMed ID: 19024182
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coronary artery bypass graft with minimal extracorporeal circulation.
    Folliguet TA; Villa E; Vandeneyden F; Laborde F
    Heart Surg Forum; 2003; 6(5):297-301. PubMed ID: 14721797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Coronary revascularization with extracorporeal circulation, aortic clamping or OPCAB: does the method's choice influence the results?].
    Coelho P; Gomes V; Silva ND; Fragata I; Ramos JS; Fragata J
    Rev Port Cir Cardiotorac Vasc; 2005; 12(1):15-9. PubMed ID: 15895122
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Off-pump coronary artery bypass grafting improves in-hospital mortality in patients with dialysis-dependent renal failure.
    Zhang L; Boyce SW; Hill PC; Sun X; Lee A; Haile E; Garcia JM; Corso PJ
    Cardiovasc Revasc Med; 2009; 10(1):12-6. PubMed ID: 19159849
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Normothermic beating heart surgery with assistance of miniaturized bypass systems: the effects on intraoperative hemodynamics and inflammatory response.
    Rex S; Brose S; Metzelder S; de Rossi L; Schroth S; Autschbach R; Rossaint R; Buhre W
    Anesth Analg; 2006 Feb; 102(2):352-62. PubMed ID: 16428521
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early and midterm results of off-pump coronary artery bypass grafting without patient selection.
    Suzuki T; Asai T
    Heart Surg Forum; 2008; 11(4):E213-7. PubMed ID: 18782699
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins.
    Nollert G; Schwabenland I; Maktav D; Kur F; Christ F; Fraunberger P; Reichart B; Vicol C
    Ann Thorac Surg; 2005 Dec; 80(6):2326-32. PubMed ID: 16305899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Compact extracorporeal circulation: reducing the surface of cardiopulmonary bypass to improve outcomes.
    Borrelli U; Al-Attar N; Detroux M; Nottin R; Nikis S; Jennes S; Nackers P; Baert G; Colinet B; Miesse C; Fijakowski J; Perron F
    Surg Technol Int; 2007; 16():159-66. PubMed ID: 17429784
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization.
    Puehler T; Haneya A; Philipp A; Wiebe K; Keyser A; Rupprecht L; Hirt S; Kobuch R; Diez C; Hilker M; Schmid C
    Ann Thorac Surg; 2009 Mar; 87(3):766-72. PubMed ID: 19231386
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.