These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Comparative study of two commercially pure titanium casting methods. Rodrigues RC; Faria AC; Orsi IA; Mattos Mda G; Macedo AP; Ribeiro RF J Appl Oral Sci; 2010; 18(5):487-92. PubMed ID: 21085805 [TBL] [Abstract][Full Text] [Related]
5. Feasibility study and material selection for powder-bed fusion process in printing of denture clasps. Ma K; Chen H; Shen Y; Guo Y; Li W; Wang Y; Zhang Y; Sun Y Comput Biol Med; 2023 May; 157():106772. PubMed ID: 36963354 [TBL] [Abstract][Full Text] [Related]
6. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps. Kim D; Park C; Yi Y; Cho L J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040 [TBL] [Abstract][Full Text] [Related]
7. Effect of arm design and chemical polishing on retentive force of cast titanium alloy clasps. Shimpo H J Prosthodont; 2008 Jun; 17(4):300-7. PubMed ID: 18205738 [TBL] [Abstract][Full Text] [Related]
8. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture. Souza JE; Silva NR; Coelho PG; Zavanelli AC; Ferracioli RC; Zavanelli RA J Contemp Dent Pract; 2011 May; 12(3):179-86. PubMed ID: 22186813 [TBL] [Abstract][Full Text] [Related]
9. Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method. Tse ET; Cheng LY; Luk HW; Chu FC; Chai J; Chow TW Int J Prosthodont; 2006; 19(4):371-2. PubMed ID: 16900820 [TBL] [Abstract][Full Text] [Related]
10. [Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting]. Ma KN; Chen H; Shen YR; Zhou YS; Wang Y; Sun YC Beijing Da Xue Xue Bao Yi Xue Ban; 2022 Feb; 54(1):105-112. PubMed ID: 35165476 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp. Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890 [TBL] [Abstract][Full Text] [Related]
12. An analytical model to design circumferential clasps for laser-sintered removable partial dentures. Alsheghri AA; Alageel O; Caron E; Ciobanu O; Tamimi F; Song J Dent Mater; 2018 Oct; 34(10):1474-1482. PubMed ID: 29937332 [TBL] [Abstract][Full Text] [Related]
13. Fatigue resistance and retentive force of cast clasps treated by shot peening. Tokue A; Hayakawa T; Ohkubo C J Prosthodont Res; 2013 Jul; 57(3):186-94. PubMed ID: 23809297 [TBL] [Abstract][Full Text] [Related]
14. The effect of reducing the number of clasps on removable partial denture retention. Ahmad I; Sherriff M; Waters NE J Prosthet Dent; 1992 Dec; 68(6):928-33. PubMed ID: 1494122 [TBL] [Abstract][Full Text] [Related]
16. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp. Vallittu PK; Kokkonen M J Prosthet Dent; 1995 Oct; 74(4):412-9. PubMed ID: 8531162 [TBL] [Abstract][Full Text] [Related]
17. Trend of change in retentive force for bar attachments with different materials. Saito M; Kanazawa M; Takahashi H; Uo M; Minakuchi S J Prosthet Dent; 2014 Dec; 112(6):1545-52. PubMed ID: 25023010 [TBL] [Abstract][Full Text] [Related]
18. The flexibility of titanium clasps compared with cobalt-chromium clasps. Essop AR; Salt SA; Sykes LM; Chandler HD; Becker PJ SADJ; 2000 Dec; 55(12):672-7. PubMed ID: 12608241 [TBL] [Abstract][Full Text] [Related]
19. Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique. Zhang M; Gan N; Qian H; Jiao T J Prosthodont Res; 2022 Jul; 66(3):459-465. PubMed ID: 34615841 [TBL] [Abstract][Full Text] [Related]
20. [Experimental study on the retentive force of cobalt-chromium alloy, pure titanium and vitallium cast clasps in the simulated 3-year clinical use]. Yan HX; Zhao YB; Qin LM; Zhu HT; Wu L Shanghai Kou Qiang Yi Xue; 2015 Dec; 24(6):696-701. PubMed ID: 27063121 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]