148 related articles for article (PubMed ID: 18950304)
1. Optimal site for atrial lead implantation in myotonic dystrophy patients: the role of Bachmann's Bundle stimulation.
Nigro G; Russo V; Vergara P; D'Andrea A; Di Gregorio G; Politano L; Nigro G; Calabrò R
Pacing Clin Electrophysiol; 2008 Nov; 31(11):1463-6. PubMed ID: 18950304
[TBL] [Abstract][Full Text] [Related]
2. Does Bachmann's bundle pacing prevent atrial fibrillation in myotonic dystrophy type 1 patients? A 12 months follow-up study.
Nigro G; Russo V; Politano L; Della Cioppa N; Rago A; Arena G; Papa AA; Paoli LD; de Chiara A; Russo MG; Golino P; Calabrò R
Europace; 2010 Sep; 12(9):1219-23. PubMed ID: 20538830
[TBL] [Abstract][Full Text] [Related]
3. Far field R-wave sensing in Myotonic Dystrophy type 1: right atrial appendage versus Bachmann's bundle region lead placement.
Russo V; Nigro G; Antonio Papa A; Rago A; Di Meo F; Cristiano A; Molino A; Calabrò R; Giovanna Russo M; Politano L
Acta Myol; 2014 Oct; 33(2):94-9. PubMed ID: 25709379
[TBL] [Abstract][Full Text] [Related]
4. Right atrial appendage versus Bachmann's bundle stimulation: a two-year comparative study of electrical parameters in myotonic dystrophy type-1 patients.
Nigro G; Russo V; Politano L; Della Cioppa N; Manfredi D; Chianese R; De Chiara A; Rago A; Arena G; Palladino A; Calabrò R
Pacing Clin Electrophysiol; 2009 Sep; 32(9):1191-6. PubMed ID: 19719498
[TBL] [Abstract][Full Text] [Related]
5. Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.
Russo V; Rago A; Papa AA; Arena G; Politano L; Nigro G
J Interv Card Electrophysiol; 2018 Apr; 51(3):229-236. PubMed ID: 29488106
[TBL] [Abstract][Full Text] [Related]
6. Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing.
Lewicka-Nowak E; Kutarski A; Dabrowska-Kugacka A; Rucinski P; Zagozdzon P; Raczak G
Europace; 2008 Feb; 10(2):138-46. PubMed ID: 18192341
[TBL] [Abstract][Full Text] [Related]
7. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.
Sławuta A; Kliś M; Skoczyński P; Bańkowski T; Moszczyńska-Stulin J; Gajek J
Adv Clin Exp Med; 2016; 25(5):845-850. PubMed ID: 28028946
[TBL] [Abstract][Full Text] [Related]
8. Pacing of Bachmann's bundle after coronary artery bypass grafting.
Goette A; Mittag J; Friedl A; Busk H; Jepsen MS; Hartung WM; Huth C; Klein HU
Pacing Clin Electrophysiol; 2002 Jul; 25(7):1072-8. PubMed ID: 12164449
[TBL] [Abstract][Full Text] [Related]
9. The effect of the atrial pacing site on the total atrial activation time.
Roithinger FX; Abou-Harb M; Pachinger O; Hintringer F
Pacing Clin Electrophysiol; 2001 Mar; 24(3):316-22. PubMed ID: 11310300
[TBL] [Abstract][Full Text] [Related]
10. Effect of pacing site on P wave parameters: Within-patient comparison of right atrial appendage and Bachmann's bundle.
Vedage NA; Cronin EM
J Electrocardiol; 2024; 84():9-14. PubMed ID: 38432160
[TBL] [Abstract][Full Text] [Related]
11. A simple method for Bachmann's bundle pacing with indigenous modification of J-stylet.
Das A; Banerjee S; Mandal SC
Indian Heart J; 2016; 68(5):678-684. PubMed ID: 27773407
[TBL] [Abstract][Full Text] [Related]
12. Alternative atrial pacing site to improve cardiac function: focus on Bachmann's bundle pacing.
Cronin EM; Vedage N; Israel CW
Eur Heart J Suppl; 2023 Nov; 25(Suppl G):G44-G55. PubMed ID: 37970517
[TBL] [Abstract][Full Text] [Related]
13. Transseptal implantation of a left ventricular pacing lead for an ectopic location of the coronary sinus ostium in the left atrium.
Mondoly P; Marachet MA; Massabuau P; Rumeau P; Maury P; Delay M; Duparc A
Pacing Clin Electrophysiol; 2013 Feb; 36(2):e51-2. PubMed ID: 21453339
[TBL] [Abstract][Full Text] [Related]
14. Interatrial electrical connections: the precise location and preferential conduction.
Sakamoto S; Nitta T; Ishii Y; Miyagi Y; Ohmori H; Shimizu K
J Cardiovasc Electrophysiol; 2005 Oct; 16(10):1077-86. PubMed ID: 16191118
[TBL] [Abstract][Full Text] [Related]
15. Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath.
Bai R; Kam R; Ching CK; Hsu LF; Teo WS
J Huazhong Univ Sci Technolog Med Sci; 2008 Dec; 28(6):639-44. PubMed ID: 19107356
[TBL] [Abstract][Full Text] [Related]
16. Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
Haghjoo M; Bonakdar HR; Jorat MV; Fazelifar AF; Alizadeh A; Ojaghi-Haghjghi Z; Esmaielzadeh M; Sadr-Ameli MA
Europace; 2009 Mar; 11(3):356-63. PubMed ID: 19136489
[TBL] [Abstract][Full Text] [Related]
17. Is Bachmann's Bundle the only right site for single-site pacing to prevent atrial fibrillation? Results of a multicenter randomized trial.
Bailin SJ
Card Electrophysiol Rev; 2003 Dec; 7(4):325-8. PubMed ID: 15071246
[TBL] [Abstract][Full Text] [Related]
18. Anatomy for atrial lead implantation.
Israel CW; Tribunyan S; Ho SY; Cabrera JA
Herzschrittmacherther Elektrophysiol; 2022 Jun; 33(2):181-185. PubMed ID: 35608664
[TBL] [Abstract][Full Text] [Related]
19. [Bachmann bundle pacing].
Israel CW; Burmistrava T; Berger C
Herz; 2018 Nov; 43(7):584-595. PubMed ID: 30255305
[TBL] [Abstract][Full Text] [Related]
20. A novel approach to transvenous dual-chamber pacing lead placement and cardiac defibrillator implantation after tricuspid valve replacement.
Lopez JA; Lufschanowski R
J Cardiovasc Electrophysiol; 2008 Aug; 19(8):873-5. PubMed ID: 18179526
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]