BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 18950304)

  • 1. Optimal site for atrial lead implantation in myotonic dystrophy patients: the role of Bachmann's Bundle stimulation.
    Nigro G; Russo V; Vergara P; D'Andrea A; Di Gregorio G; Politano L; Nigro G; Calabrò R
    Pacing Clin Electrophysiol; 2008 Nov; 31(11):1463-6. PubMed ID: 18950304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does Bachmann's bundle pacing prevent atrial fibrillation in myotonic dystrophy type 1 patients? A 12 months follow-up study.
    Nigro G; Russo V; Politano L; Della Cioppa N; Rago A; Arena G; Papa AA; Paoli LD; de Chiara A; Russo MG; Golino P; Calabrò R
    Europace; 2010 Sep; 12(9):1219-23. PubMed ID: 20538830
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Far field R-wave sensing in Myotonic Dystrophy type 1: right atrial appendage versus Bachmann's bundle region lead placement.
    Russo V; Nigro G; Antonio Papa A; Rago A; Di Meo F; Cristiano A; Molino A; Calabrò R; Giovanna Russo M; Politano L
    Acta Myol; 2014 Oct; 33(2):94-9. PubMed ID: 25709379
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Right atrial appendage versus Bachmann's bundle stimulation: a two-year comparative study of electrical parameters in myotonic dystrophy type-1 patients.
    Nigro G; Russo V; Politano L; Della Cioppa N; Manfredi D; Chianese R; De Chiara A; Rago A; Arena G; Palladino A; Calabrò R
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1191-6. PubMed ID: 19719498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.
    Russo V; Rago A; Papa AA; Arena G; Politano L; Nigro G
    J Interv Card Electrophysiol; 2018 Apr; 51(3):229-236. PubMed ID: 29488106
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing.
    Lewicka-Nowak E; Kutarski A; Dabrowska-Kugacka A; Rucinski P; Zagozdzon P; Raczak G
    Europace; 2008 Feb; 10(2):138-46. PubMed ID: 18192341
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.
    Sławuta A; Kliś M; Skoczyński P; Bańkowski T; Moszczyńska-Stulin J; Gajek J
    Adv Clin Exp Med; 2016; 25(5):845-850. PubMed ID: 28028946
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pacing of Bachmann's bundle after coronary artery bypass grafting.
    Goette A; Mittag J; Friedl A; Busk H; Jepsen MS; Hartung WM; Huth C; Klein HU
    Pacing Clin Electrophysiol; 2002 Jul; 25(7):1072-8. PubMed ID: 12164449
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of the atrial pacing site on the total atrial activation time.
    Roithinger FX; Abou-Harb M; Pachinger O; Hintringer F
    Pacing Clin Electrophysiol; 2001 Mar; 24(3):316-22. PubMed ID: 11310300
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of pacing site on P wave parameters: Within-patient comparison of right atrial appendage and Bachmann's bundle.
    Vedage NA; Cronin EM
    J Electrocardiol; 2024; 84():9-14. PubMed ID: 38432160
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple method for Bachmann's bundle pacing with indigenous modification of J-stylet.
    Das A; Banerjee S; Mandal SC
    Indian Heart J; 2016; 68(5):678-684. PubMed ID: 27773407
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Alternative atrial pacing site to improve cardiac function: focus on Bachmann's bundle pacing.
    Cronin EM; Vedage N; Israel CW
    Eur Heart J Suppl; 2023 Nov; 25(Suppl G):G44-G55. PubMed ID: 37970517
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transseptal implantation of a left ventricular pacing lead for an ectopic location of the coronary sinus ostium in the left atrium.
    Mondoly P; Marachet MA; Massabuau P; Rumeau P; Maury P; Delay M; Duparc A
    Pacing Clin Electrophysiol; 2013 Feb; 36(2):e51-2. PubMed ID: 21453339
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Interatrial electrical connections: the precise location and preferential conduction.
    Sakamoto S; Nitta T; Ishii Y; Miyagi Y; Ohmori H; Shimizu K
    J Cardiovasc Electrophysiol; 2005 Oct; 16(10):1077-86. PubMed ID: 16191118
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath.
    Bai R; Kam R; Ching CK; Hsu LF; Teo WS
    J Huazhong Univ Sci Technolog Med Sci; 2008 Dec; 28(6):639-44. PubMed ID: 19107356
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
    Haghjoo M; Bonakdar HR; Jorat MV; Fazelifar AF; Alizadeh A; Ojaghi-Haghjghi Z; Esmaielzadeh M; Sadr-Ameli MA
    Europace; 2009 Mar; 11(3):356-63. PubMed ID: 19136489
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is Bachmann's Bundle the only right site for single-site pacing to prevent atrial fibrillation? Results of a multicenter randomized trial.
    Bailin SJ
    Card Electrophysiol Rev; 2003 Dec; 7(4):325-8. PubMed ID: 15071246
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Anatomy for atrial lead implantation.
    Israel CW; Tribunyan S; Ho SY; Cabrera JA
    Herzschrittmacherther Elektrophysiol; 2022 Jun; 33(2):181-185. PubMed ID: 35608664
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Bachmann bundle pacing].
    Israel CW; Burmistrava T; Berger C
    Herz; 2018 Nov; 43(7):584-595. PubMed ID: 30255305
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel approach to transvenous dual-chamber pacing lead placement and cardiac defibrillator implantation after tricuspid valve replacement.
    Lopez JA; Lufschanowski R
    J Cardiovasc Electrophysiol; 2008 Aug; 19(8):873-5. PubMed ID: 18179526
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.