BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 18955406)

  • 1. Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.
    Barold SS; Ilercil A; Herweg B
    Europace; 2008 Nov; 10 Suppl 3():iii88-95. PubMed ID: 18955406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interventricular delay interval optimization in cardiac resynchronization therapy guided by echocardiography versus guided by electrocardiographic QRS interval width.
    Bertini M; Ziacchi M; Biffi M; Martignani C; Saporito D; Valzania C; Diemberger I; Cervi E; Frisoni J; Sangiorgi D; Branzi A; Boriani G
    Am J Cardiol; 2008 Nov; 102(10):1373-7. PubMed ID: 18993158
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac resynchronization therapy: variations in echo-guided optimized atrioventricular and interventricular delays during follow-up.
    Valzania C; Biffi M; Martignani C; Diemberger I; Bertini M; Ziacchi M; Bacchi L; Rocchi G; Rapezzi C; Branzi A; Boriani G
    Echocardiography; 2007 Oct; 24(9):933-9. PubMed ID: 17894571
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Pacemaker optimization guided by echocardiography in cardiac resynchronization therapy].
    Trifunović D; Petrović M; Milasinović G; Vujisić-Tesić B; Boricić M; Nedeljković I; Jelić V; Zivković M; Jovanović V; Petrović O
    Srp Arh Celok Lek; 2009; 137(7-8):416-22. PubMed ID: 19764597
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intracardiac echocardiography-guided cardiac resynchronization therapy: technique and clinical application.
    Saksena S; Simon AM; Mathew P; Nagarakanti R
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1030-9. PubMed ID: 19659623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prospective comparison of echocardiography and device algorithms for atrioventricular and interventricular interval optimization in cardiac resynchronization therapy.
    Kamdar R; Frain E; Warburton F; Richmond L; Mullan V; Berriman T; Thomas G; Tenkorang J; Dhinoja M; Earley M; Sporton S; Schilling R
    Europace; 2010 Jan; 12(1):84-91. PubMed ID: 19892713
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Acute evaluation of programmer-guided AV/PV and VV delay optimization comparing an IEGM method and echocardiogram for cardiac resynchronization therapy in heart failure patients and dual-chamber ICD implants.
    Baker JH; McKenzie J; Beau S; Greer GS; Porterfield J; Fedor M; Greenberg S; Daoud EG; Corbisiero R; Bailey JR; Porterfield L
    J Cardiovasc Electrophysiol; 2007 Feb; 18(2):185-91. PubMed ID: 17338767
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective randomized evaluation of VV delay optimization in CRT-D recipients: echocardiographic observations from the RHYTHM II ICD study.
    Boriani G; Biffi M; Müller CP; Seidl KH; Grove R; Vogt J; Danschel W; Schuchert A; Deharo JC; Becker T; Boulogne E; Trappe HJ;
    Pacing Clin Electrophysiol; 2009 Mar; 32 Suppl 1():S120-5. PubMed ID: 19250074
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interventricular delay optimization: a comparison among three different echocardiographic methods.
    Bertini M; Valzania C; Biffi M; Martignani C; Ziacchi M; Pedri S; Domenichini G; Diemberger I; Saporito D; Rocchi G; Rapezzi C; Branzi A; Boriani G
    Echocardiography; 2010 Jan; 27(1):38-43. PubMed ID: 19725848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Doppler echocardiographic methods for optimization of the atrioventricular delay during cardiac resynchronization therapy.
    Waggoner AD; de las Fuentes L; Davila-Roman VG
    Echocardiography; 2008 Oct; 25(9):1047-55. PubMed ID: 18986435
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy.
    Kerlan JE; Sawhney NS; Waggoner AD; Chawla MK; Garhwal S; Osborn JL; Faddis MN
    Heart Rhythm; 2006 Feb; 3(2):148-54. PubMed ID: 16443528
    [TBL] [Abstract][Full Text] [Related]  

  • 12. AV junctional ablation allowing more effective delivery of cardiac resynchronization therapy in patients with intra- and interatrial conduction delay.
    Herweg B; Ilercil A; Madramootoo C; Ali R; Barold SS
    Pacing Clin Electrophysiol; 2008 Jun; 31(6):685-90. PubMed ID: 18507540
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac resynchronization therapy with sequential biventricular pacing: impact of echocardiography guided VV delay optimization on acute results.
    Parreira L; Santos JF; Madeira J; Mendes L; Seixo F; Caetano F; Lopes C; Venãncio J; Mateus A; Inês JL; Mendes M
    Rev Port Cardiol; 2005 Nov; 24(11):1355-65. PubMed ID: 16463985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac resynchronization therapy during rest and exercise: comparison of two optimization methods.
    Valzania C; Eriksson MJ; Boriani G; Gadler F
    Europace; 2008 Oct; 10(10):1161-9. PubMed ID: 18753213
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shorter AV delays provide improved echocardiographic hemodynamics during exercise in patients receiving cardiac resynchronization therapy.
    Grimm RA; Sun JP; Agler D; Fitzgerald B; Wilkoff B; Hilpisch K; Perlic G; Chinchoy E
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):457-65. PubMed ID: 19335854
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Whether noninvasive optimization of AV and VV delays improves the response to cardiac resynchronization therapy.
    Urbanek B; Chudzik M; Klimczak A; Rosiak M; Lewek J; Wranicz JK
    Cardiol J; 2013; 20(4):411-7. PubMed ID: 23913460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Echocardiographic effects of changing atrioventricular delay in cardiac resynchronization therapy based on displacement.
    Valeur N; Fritz-Hansen T; Risum N; Mogelvang R; Bloch Thomsen PE; Søgaard P
    J Am Soc Echocardiogr; 2010 Jun; 23(6):621-7. PubMed ID: 20497861
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices.
    Heinroth KM; Elster M; Nuding S; Schlegel F; Christoph A; Carter J; Buerke M; Werdan K
    Europace; 2007 Sep; 9(9):744-50. PubMed ID: 17496288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fusion-optimized intervals (FOI): a new method to achieve the narrowest QRS for optimization of the AV and VV intervals in patients undergoing cardiac resynchronization therapy.
    Arbelo E; Tolosana JM; Trucco E; Penela D; Borràs R; Doltra A; Andreu D; Aceña M; Berruezo A; Sitges M; Mansour F; Castel A; Matas M; Brugada J; Mont L
    J Cardiovasc Electrophysiol; 2014 Mar; 25(3):283-92. PubMed ID: 24237881
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Usefulness of atrioventricular delay optimization using Doppler assessment of mitral inflow in patients undergoing cardiac resynchronization therapy.
    Kedia N; Ng K; Apperson-Hansen C; Wang C; Tchou P; Wilkoff BL; Grimm RA
    Am J Cardiol; 2006 Sep; 98(6):780-5. PubMed ID: 16950184
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.