These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 18961139)

  • 1. Some optical studies with the air-acetylene flame.
    Aldous KM; Browner RF; Clark D; Dagnall RM; West TS
    Talanta; 1972 Aug; 19(8):927-36. PubMed ID: 18961139
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The application of separated flames in analytical flame spectroscopy.
    Kirkbright GF; West TS
    Appl Opt; 1968 Jul; 7(7):1305-11. PubMed ID: 20068791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Studies in atomic-fluorescence spectroscopy-VII Fluorescence and analytical characteristics of arsenic, with a microwave excited electrodeless discharge tube as source.
    Dagnall RM; Thompson KC; West TS
    Talanta; 1968 Jul; 15(7):677-87. PubMed ID: 18960349
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spectroscopy in separated flames-I. The use of the separated air-acetylene flame in thermal emission spectroscopy.
    Kirkbright GF; Semb A; West TS
    Talanta; 1967 Sep; 14(9):1011-9. PubMed ID: 18960197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spectroscopy in separated flames-IV: application of the nitrogen-separated air-acetylene flame in flame-emission and atomic-fluorescence spectroscopy.
    Hobbs RS; Kirkbright GF; Sargent M; West TS
    Talanta; 1968 Oct; 15(10):997-1007. PubMed ID: 18960398
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Atomic absorption spectroscopy with high temperature flames.
    Willis JB
    Appl Opt; 1968 Jul; 7(7):1295-304. PubMed ID: 20068790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atomic emission characteristics of a premixed acetylene-nitrous oxide, total consumption flame.
    Mossotti VG; Duggan M
    Appl Opt; 1968 Jul; 7(7):1325-30. PubMed ID: 20068795
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Emission spectra of nitrous oxide supported acetylene flames at atmospheric pressure.
    Kirkbright GF; Peters MK; West TS
    Talanta; 1967 Jul; 14(7):789-800. PubMed ID: 18960164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. spectroscopy in separated flames-VI The argon or nitrogen-sheathed nitrous oxide-acetylene flame in atomic-absorption spectroscopy.
    Kirkbright GF; Sargent M; West TS
    Talanta; 1969 Nov; 16(11):1467-75. PubMed ID: 18960659
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental study on a comparison of typical premixed combustible gas-air flame propagation in a horizontal rectangular closed duct.
    Jin K; Duan Q; Liew KM; Peng Z; Gong L; Sun J
    J Hazard Mater; 2017 Apr; 327():116-126. PubMed ID: 28056399
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spectroscopy in separated flames-III Use of the separated nitrous oxide-acetylene flame in thermal emission spectroscopy.
    Kirkbright GF; Semb A; West TS
    Talanta; 1968 May; 15(5):441-50. PubMed ID: 18960318
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spectroscopy in separated flames-II The use of the separated air-acetylene flame in long path atomic absorption spectroscopy.
    Hingle DN; Kirkbright GF; West TS
    Talanta; 1968 Feb; 15(2):199-206. PubMed ID: 18960280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature measurements in steady axisymmetric partially premixed flames by use of rainbow schlieren deflectometry.
    Xiao X; Puri IK; Agrawal AK
    Appl Opt; 2002 Apr; 41(10):1922-8. PubMed ID: 11936791
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flame temperature and location measurements of sooting premixed Bunsen flames by rainbow schlieren deflectometry.
    Ibarreta AF; Sung CJ
    Appl Opt; 2005 Jun; 44(17):3565-75. PubMed ID: 16007857
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spectroscopy in separated flames-V The argon- or nitrogen-sheathed nitrous oxide-acetylene flame in flame emission spectroscopy.
    Kirkbright GF; Sargent M; West TS
    Talanta; 1969 Feb; 16(2):245-53. PubMed ID: 18960492
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of indium in aluminium alloys by flame atomic-absorption spectroscopy and flame atomic-emission spectrometry.
    Bernal JL; Del Nozal MJ; Deban L; Aller AJ
    Talanta; 1982 Dec; 29(12):1113-6. PubMed ID: 18963265
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The oxygen-shielded air-acetylene flame in emission analysis.
    Curtis KE; Stevenson RG; Stephens R
    Talanta; 1974 Jul; 21(7):792-6. PubMed ID: 18961535
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nitrous oxide supported flames for atomic absorption spectroscopy.
    Butler LR; Fulton A
    Appl Opt; 1968 Oct; 7(10):2131-7. PubMed ID: 20068948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-dispersive atomic-fluorescence spectrometry of trace amounts of bismuth by introduction of its gaseous hydride into a premixed argon (entrained air)-hydrogen flame.
    Kobayashi S; Nakahara T; Musha S
    Talanta; 1979 Oct; 26(10):951-7. PubMed ID: 18962549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of an oxygen-shielded air-acetylene flame to atomic spectroscopy.
    Stephens R
    Talanta; 1973 Aug; 20(8):765-73. PubMed ID: 18961343
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.