These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
28 related articles for article (PubMed ID: 18962268)
1. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values. Petersen PH; Lund F; Fraser CG; Sölétormos G Ann Clin Biochem; 2016 Nov; 53(6):686-691. PubMed ID: 27147623 [TBL] [Abstract][Full Text] [Related]
2. Effects of point configuration on the accuracy in 3D reconstruction from biplane images. Dmochowski J; Hoffmann KR; Singh V; Xu J; Nazareth DP Med Phys; 2005 Sep; 32(9):2862-9. PubMed ID: 16266100 [TBL] [Abstract][Full Text] [Related]
3. An efficient optimization technique for recovering ventilation-perfusion distributions from inert gas data. Effects of random experimental error. Jaliwala SA; Mates RE; Klocke FJ J Clin Invest; 1975 Jan; 55(1):188-92. PubMed ID: 1109178 [TBL] [Abstract][Full Text] [Related]
4. Analytical goals for the estimation of non-Gaussian reference intervals. Hyltoft Petersen P; Gowans EM; Blaabjerg O; Hørder M Scand J Clin Lab Invest; 1989 Dec; 49(8):727-37. PubMed ID: 2617130 [TBL] [Abstract][Full Text] [Related]
5. A critical examination of analytical error. Harris WE Talanta; 1978 Jun; 25(6):325-9. PubMed ID: 18962268 [TBL] [Abstract][Full Text] [Related]
6. Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity. Klee GG Clin Chem; 1993 Jul; 39(7):1514-8. PubMed ID: 8330413 [TBL] [Abstract][Full Text] [Related]
7. Analytical goals developed from the inherent error of medical tests. Ross JW; Fraser MD Clin Chem; 1993 Jul; 39(7):1481-93; discussion 1493-4. PubMed ID: 8330410 [TBL] [Abstract][Full Text] [Related]
8. [Analytical uncertainty--how wrong can a laboratory result be?]. Bolann BJ; Stølsnes B Tidsskr Nor Laegeforen; 1999 Dec; 119(30):4472-5. PubMed ID: 10827487 [TBL] [Abstract][Full Text] [Related]
9. Graphical interpretation of confidence curves in rankit plots. Hyltoft Petersen P; Blaabjerg O; Andersen M; Jørgensen LG; Schousboe K; Jensen E Clin Chem Lab Med; 2004; 42(7):715-24. PubMed ID: 15327005 [TBL] [Abstract][Full Text] [Related]
10. Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors. Stroobants AK; Goldschmidt HM; Plebani M Clin Chim Acta; 2003 Jul; 333(2):169-76. PubMed ID: 12849900 [TBL] [Abstract][Full Text] [Related]
11. Cognitive diagnostic error in internal medicine. van den Berge K; Mamede S Eur J Intern Med; 2013 Sep; 24(6):525-9. PubMed ID: 23566942 [TBL] [Abstract][Full Text] [Related]