These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 18962651)

  • 21. Thermodynamic characterization of the adsorption of selected chiral compounds on immobilized amyloglucosidase in liquid chromatography.
    Götmar G; Samuelsson J; Karlsson A; Fornstedt T
    J Chromatogr A; 2007 Jul; 1156(1-2):3-13. PubMed ID: 17240382
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Theoretical investigations of the chromatographic separation of interacting enantiomers.
    Szabelski P; Kaczmarski K
    J Chromatogr A; 2006 Apr; 1113(1-2):74-83. PubMed ID: 16473359
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Heterogeneity of adsorption mechanisms in chiral normal-phase liquid chromatography. 2-Propanol and ethyl acetate adsorption equilibria.
    Cavazzini A; Nadalini G; Costa V; Dondi F
    J Chromatogr A; 2007 Mar; 1143(1-2):134-42. PubMed ID: 17239892
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Peak shapes of acids and bases under overloaded conditions in reversed-phase liquid chromatography, with weakly buffered mobile phases of various pH: a thermodynamic interpretation.
    Gritti F; Guiochon G
    J Chromatogr A; 2009 Jan; 1216(1):63-78. PubMed ID: 19054520
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of enantioselective HPLC separation of structurally diverse compounds on chiral stationary phases with different teicoplanin coverage and distinct linkage chemistry.
    Honetschlägerová-Vadinská M; Srkalová S; Bosáková Z; Coufal P; Tesarová E
    J Sep Sci; 2009 May; 32(10):1704-11. PubMed ID: 19391176
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Ionic liquids versus triethylamine as mobile phase additives in the analysis of beta-blockers.
    Ruiz-Angel MJ; Carda-Broch S; Berthod A
    J Chromatogr A; 2006 Jun; 1119(1-2):202-8. PubMed ID: 16386264
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prediction of a protein band profile in preparative reversed-phase gradient elution chromatography.
    El Fallah MZ; Guiochon G
    Biotechnol Bioeng; 1992 Apr; 39(8):877-85. PubMed ID: 18601022
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect on separation of injecting samples in a solvent different from the mobile phase.
    Gedicke K; Antos D; Seidel-Morgenstern A
    J Chromatogr A; 2007 Aug; 1162(1):62-73. PubMed ID: 17331517
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Separation of lactic acid from acetic acid using a four-zone SMB.
    Lee HJ; Xie Y; Koo YM; Wang NH
    Biotechnol Prog; 2004; 20(1):179-92. PubMed ID: 14763841
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Thermodynamic origin of the chiral recognition of tryptophan on teicoplanin and teicoplanin aglycone stationary phases.
    Haroun M; Ravelet C; Ravel A; Grosset C; Villet A; Peyrin E
    J Sep Sci; 2005 Mar; 28(5):409-20. PubMed ID: 15835728
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Breakthrough curves and elution profiles of single solutes in case of adsorption isotherms with two inflection points.
    Zhang W; Shan Y; Seidel-Morgenstern A
    J Chromatogr A; 2006 Feb; 1107(1-2):216-25. PubMed ID: 16442120
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Improved efficiency in micellar liquid chromatography using triethylamine and 1-butanol as mobile phase additives to reduce surfactant adsorption.
    Thomas DP; Foley JP
    J Chromatogr A; 2008 Sep; 1205(1-2):36-45. PubMed ID: 18721924
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Theoretical study of preparative chromatography using closed-loop recycling with an initial gradient.
    Sreedhar B; Damtew A; Seidel-Morgenstern A
    J Chromatogr A; 2009 Jun; 1216(25):4976-88. PubMed ID: 19447399
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Deformation of gradient shape as a result of preferential adsorption of solvents in mixed mobile phases.
    Piatkowski W; Kramarz R; Poplewska I; Antos D
    J Chromatogr A; 2006 Sep; 1127(1-2):187-99. PubMed ID: 16814799
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High-performance liquid chromatographic chiral separation of beta2-homoamino acids.
    Pataj Z; Berkecz R; Ilisz I; Misicka A; Tymecka D; Fülöp F; Armstrong DW; Péter A
    Chirality; 2009 Oct; 21(9):787-98. PubMed ID: 18979532
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimization of simulated moving bed and column chromatography for a plasmid DNA purification step and for a chiral separation.
    Paredes G; Mazzotti M
    J Chromatogr A; 2007 Feb; 1142(1):56-68. PubMed ID: 17188694
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Preparative chromatography with supercritical fluids. Comparison of simulated moving bed and batch processes.
    Peper S; Johannsen M; Brunner G
    J Chromatogr A; 2007 Dec; 1176(1-2):246-53. PubMed ID: 17988674
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Direct TLC resolution of atenolol and propranolol into their enantiomers using three different chiral selectors as impregnating reagents.
    Bhushan R; Tanwar S
    Biomed Chromatogr; 2008 Sep; 22(9):1028-34. PubMed ID: 18506901
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Behavior of adsorbed and fluid phases versus retention properties of amino acids on the teicoplanin chiral selector.
    Poplewska I; Kramarz R; Piatkowski W; Seidel-Morgenstern A; Antos D
    J Chromatogr A; 2008 May; 1192(1):130-8. PubMed ID: 18417142
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Features of the adsorption of naproxen enantiomers on weak chiral anion-exchangers in nonlinear chromatography.
    Asnin L; Kaczmarski K; Guiochon G
    J Chromatogr A; 2008 May; 1192(1):62-73. PubMed ID: 18377915
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.