These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 18965924)

  • 1. Catalytic-voltammetric determination of the antioxidant tert-butylhydroxyanisole (BHA) at a nickel phthalocyanine modified carbon paste electrode.
    Ruiz MA; Calvo MP; Pingarrón JM
    Talanta; 1994 Feb; 41(2):289-94. PubMed ID: 18965924
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Voltammetric determination of the phenolic antioxidants 3-tert-butyl-4-hydroxyanisole and tert-butylhydroquinone at a polypyrrole electrode modified with a nickel phthalocyanine complex.
    de la Fuente C; Acuña JA; Vázquez MD; Tascón ML; Sánchez Batanero P
    Talanta; 1999 Jun; 49(2):441-52. PubMed ID: 18967617
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gold nanoparticles modified carbon paste electrode for differential pulse voltammetric determination of eugenol.
    Afzali D; Zarei S; Fathirad F; Mostafavi A
    Mater Sci Eng C Mater Biol Appl; 2014 Oct; 43():97-101. PubMed ID: 25175193
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Voltammetric determination of cysteine using carbon paste electrode modified with Co(II)-Y zeolite.
    Nezamzadeh-Ejhieh A; Hashemi HS
    Talanta; 2012 Jan; 88():201-8. PubMed ID: 22265488
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electroregenerable anion-exchange resin with triiodide carbon paste electrode for the voltammetric determination of adrenaline.
    Lupetti KO; Vieira IC; Vieira HJ; Fatibello-Filhoa O
    Analyst; 2002 Apr; 127(4):525-9. PubMed ID: 12022653
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Voltammetric study of glibenclamide at carbon paste and Sephadex-modified carbon paste electrodes.
    Radi A
    Anal Bioanal Chem; 2004 Feb; 378(3):822-6. PubMed ID: 14685817
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electroanalytical Determination of Escitalopram Oxalate Using Nickel Nanoparticles Modified Carbon Paste Sensor.
    Attia K; Mohamed AM; Fekry MA
    Acta Chim Slov; 2017 Jun; 64(2):415-421. PubMed ID: 28621385
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Voltammetric sensor based on carbon paste electrode modified with molecular imprinted polymer for determination of sulfadiazine in milk and human serum.
    Sadeghi S; Motaharian A
    Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4884-91. PubMed ID: 24094201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous determination of lead(II) and cadmium(II) at a diacetyldioxime modified carbon paste electrode by differential pulse stripping voltammetry.
    Hu C; Wu K; Dai X; Hu S
    Talanta; 2003 May; 60(1):17-24. PubMed ID: 18969020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Study of kinetic parameters and development of a voltammetric sensor for the determination of butylated hydroxyanisole (BHA) in oil samples.
    Thomas D; Rasheed Z; Jagan JS; Kumar KG
    J Food Sci Technol; 2015 Oct; 52(10):6719-26. PubMed ID: 26396421
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a carbon paste electrode modified with organofunctionalized amorphous silica in the cadmium determination in a differential pulse anodic stripping voltammetric procedure.
    Marino G; Bergamini MF; Teixeira MF; Cavalheiro ET
    Talanta; 2003 Apr; 59(5):1021-8. PubMed ID: 18968993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrochemical sensor for ranitidine determination based on carbon paste electrode modified with oxovanadium (IV) salen complex.
    Raymundo-Pereira PA; Teixeira MF; Fatibello-Filho O; Dockal ER; Bonifácio VG; Marcolino LH
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4081-5. PubMed ID: 23910317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A carbon paste electrode modified with poly(methylene disulfide) nanoparticles for anodic stripping voltammetric determination of silver(I).
    Ghalebi SM; Zare-Shahabadi V; Parham H
    Mikrochim Acta; 2019 Jan; 186(2):60. PubMed ID: 30627865
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrochemical study of the antineoplastic agent etoposide at carbon paste electrode and its determination in spiked human serum by differential pulse voltammetry.
    Radi AE; Abd-Elghany N; Wahdan T
    Chem Pharm Bull (Tokyo); 2007 Sep; 55(9):1379-82. PubMed ID: 17827766
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrocatalytic characteristics of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon-paste electrode in the oxidation of ascorbic acid.
    Raoof JB; Ojani R; Hosseinzadeh R; Ghasemi V
    Anal Sci; 2003 Sep; 19(9):1251-8. PubMed ID: 14516075
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Voltammetric determination of the antioxidant capacity in wine samples using a carbon nanotube modified electrode.
    Souza LP; Calegari F; Zarbin AJ; Marcolino-Junior LH; Bergamini MF
    J Agric Food Chem; 2011 Jul; 59(14):7620-5. PubMed ID: 21692474
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new sensitive sensor for simultaneous differential pulse voltammetric determination of codeine and acetaminophen using a hydroquinone derivative and multiwall carbon nanotubes carbon paste electrode.
    Garazhian E; Shishehbore MR
    Int J Anal Chem; 2015; 2015():783157. PubMed ID: 25945094
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin.
    Mehmeti E; Stanković DM; Chaiyo S; Švorc Ľ; Kalcher K
    Mikrochim Acta; 2016; 183():1619-1624. PubMed ID: 27217592
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanically immobilized nickel aquapentacyanoferrate modified electrode as an amperometric sensor for the determination of BHA.
    Kumar SS; Narayanan SS
    Talanta; 2008 Jun; 76(1):54-9. PubMed ID: 18585240
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Voltammetric behavior of tiopronin on carbon paste electrode modified with nanocrystalline Fe₅₀Ni₅₀ alloys.
    Baghayeri M; Maleki B; Zarghani R
    Mater Sci Eng C Mater Biol Appl; 2014 Nov; 44():175-82. PubMed ID: 25280694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.