These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 18966772)

  • 1. Determination of halides by microwave induced plasma and stabilized capacitive plasma atomic emission spectrometry after on-line continuous halogen generation.
    Camuña JF; Montes M; Pereiro R; Sanz-Medel A; Katschthaler C; Gross R; Knapp G
    Talanta; 1997 Apr; 44(4):535-44. PubMed ID: 18966772
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of carbon in aqueous solutions by atmospheric-pressure helium microwave induced plasma atomic emission spectrometry with gas-phase sample introduction technique.
    Matsumoto A; Nakahara T
    Anal Sci; 2003 Mar; 19(3):395-400. PubMed ID: 12675347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative study of a beenakker cavity and a surfatron in combination with electrothermal evaporation from a tungsten coil for microwave plasma optical emission spectrometry (MIP-AES).
    Richts U; Broekaert JA; Tschöpel P; Tölg G
    Talanta; 1991 Aug; 38(8):863-9. PubMed ID: 18965230
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microwave-based strategies for sample preparation and halogen determination in blood using ICP-MS.
    Waechter SR; Vecchia PD; Barin JS; Flores EMM; Duarte FA
    Talanta; 2021 May; 226():122157. PubMed ID: 33676704
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of gaseous semi- and low-volatile organic halogen compounds by barrier-discharge atomic emission spectrometry.
    Sun Y; Watanabe N; Wang W; Zhu T
    J Environ Sci (China); 2013 Jan; 25(1):213-9. PubMed ID: 23586317
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of vapor generation for the determination of nickel by inductively coupled plasma-atomic emission spectrometry.
    Marrero J; Smichowski P
    Anal Bioanal Chem; 2002 Sep; 374(2):196-202. PubMed ID: 12324837
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of non-metallic elements by capacitively coupled helium microwave plasma atomic emission spectrometry with capillary gas chromatography.
    Uchida H; Berthod A; Winefordner JD
    Analyst; 1990 Jul; 115(7):933-7. PubMed ID: 2221401
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique.
    Engel U; Bilgiç AM; Haase O; Voges E; Broekaert JA
    Anal Chem; 2000 Jan; 72(1):193-7. PubMed ID: 10655653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous determination of bismuth and tellurium in steels by high power nitrogen microwave induced plasma atomic emission spectrometry coupled with the hydride generation technique.
    Matsumoto A; Shiozaki T; Nakahara T
    Anal Bioanal Chem; 2004 May; 379(1):90-5. PubMed ID: 14747893
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Helium microwave-induced plasma mass spectrometric detection for reversed-phase high-performance liquid chromatography.
    Heitkemper D; Creed J; Caruso JA
    J Chromatogr Sci; 1990 Apr; 28(4):175-81. PubMed ID: 2079547
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of electrochemical hydride generation in a miniaturized electrolytic flow cell coupled to microwave-induced plasma atomic emission spectrometry for the determination of selenium.
    Schermer S; Jurica L; Paumard J; Beinrohr E; Matysik FM; Broekaert JA
    Fresenius J Anal Chem; 2001 Nov; 371(6):740-5. PubMed ID: 11768460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sb(III) and Sb(V) separation and analytical speciation by a continuous tandem on-line separation device in connection with inductively coupled plasma atomic emission spectrometry.
    García AM; Rodríguez MC; Uria JE; Sanz-Medel A
    Anal Bioanal Chem; 1995 Sep; 353(2):128-32. PubMed ID: 15048526
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an element-selective monitoring system for adsorbable organic halogens (AOX) with plasma emission spectrometric detection for quasi-continuous waste-water analysis.
    Twiehaus T; Evers S; Buscher W; Cammann K
    Fresenius J Anal Chem; 2001 Nov; 371(5):614-20. PubMed ID: 11767887
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preliminary characterization of a low-powered microwave induced flame plasma for direct organic solvent nebulization.
    Ng KC; Bucay P
    Rev Sci Instrum; 2011 Dec; 82(12):125101. PubMed ID: 22225243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Speciation of inorganic selenium using capillary electrophoresis-inductively coupled plasma-atomic emission spectrometry with on-line hydride generation.
    Deng B; Feng J; Meng J
    Anal Chim Acta; 2007 Jan; 583(1):92-7. PubMed ID: 17386531
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of halogenated hydrocarbons by helium microwave plasma torch time-of-flight mass spectrometry coupled to gas chromatography.
    Pack BW; Broekaert JA; Guzowski JP; Poehlman J; Hieftje GM
    Anal Chem; 1998 Sep; 70(18):3957-63. PubMed ID: 9751030
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Atomic/ionic fluorescence in microwave plasma torch discharge with excitation of high current and microsecond pulsed hollow cathode lamp: Ca atomic/ionic fluorescence spectrometry].
    Gong ZB; Liang F; Yang PY; Jin QH; Huang BL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Feb; 22(1):63-6. PubMed ID: 12940030
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Release of gas-phase halogens by photolytic generation of OH in frozen halide-nitrate solutions: an active halogen formation mechanism?
    Abbatt J; Oldridge N; Symington A; Chukalovskiy V; McWhinney RD; Sjostedt S; Cox RA
    J Phys Chem A; 2010 Jun; 114(23):6527-33. PubMed ID: 20481568
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microplasma source based on a dielectric barrier discharge for the determination of mercury by atomic emission spectrometry.
    Zhu Z; Chan GC; Ray SJ; Zhang X; Hieftje GM
    Anal Chem; 2008 Nov; 80(22):8622-7. PubMed ID: 18937424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of bromide by low power surfatron microwave induced plasma after bromine continuous generation.
    Calzada MD; Quintero MC; Gamero A; Cotrino J; Uría JE; Sanz-Medel A
    Talanta; 1992 Apr; 39(4):341-7. PubMed ID: 18965385
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.