These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 18966840)

  • 1. A novel potassium ion membrane sensor based on rifamycin neutral ionophore.
    Hassan SS; Mahmoud WH; Othman AH
    Talanta; 1997 Jun; 44(6):1087-94. PubMed ID: 18966840
    [TBL] [Abstract][Full Text] [Related]  

  • 2. DDB liver drug as a novel ionophore for potentiometric barium (II) membrane sensor.
    Hassan SS; Saleh MB; Abdel Gaber AA; Abdel Kream NA
    Talanta; 2003 Jan; 59(1):161-6. PubMed ID: 18968896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PVC membrane sensor for potentiometric determination of iron (II) in some pharmaceutical formulations based on a new neutral ionophore.
    Abounassif MA; Al-Omar MA; Amr AG; Mostafa GA
    Drug Test Anal; 2011 Jun; 3(6):373-9. PubMed ID: 21698780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone.
    Mahajan RK; Kaur I; Lobana TS
    Talanta; 2003 Jan; 59(1):101-5. PubMed ID: 18968889
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions.
    Ganjali MR; Mizani F; Salavati-Niasari M; Javanbakht M
    Anal Sci; 2003 Feb; 19(2):235-8. PubMed ID: 12608751
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mercury(II) ion-selective electrodes based on p-tert-butyl calix[4]crowns with imine units.
    Mahajan RK; Kaur R; Kaur I; Sharma V; Kumar M
    Anal Sci; 2004 May; 20(5):811-4. PubMed ID: 15171285
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
    Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
    Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as neutral carrier.
    Mashhadizadeh MH; Momeni A
    Talanta; 2003 Jan; 59(1):47-53. PubMed ID: 18968883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cadmium ion-selective electrode based on tetrathia-12-crown-4.
    Shamsipur M; Mashhadizadeh MH
    Talanta; 2001 Jan; 53(5):1065-71. PubMed ID: 18968198
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PVC membrane based potentiometric sensors for uranium determination.
    Hassan SS; Ali MM; Attawiya AM
    Talanta; 2001 Jul; 54(6):1153-61. PubMed ID: 18968336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. PVC membrane potentiometric sensor based on 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline-phane for selective determination of neodymium(III).
    Shamsipur M; Hosseini M; Alizadeh K; Mousavi MF; Garau A; Lippolis V; Yari A
    Anal Chem; 2005 Jan; 77(1):276-83. PubMed ID: 15623306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PVC-based 1,3,5-trithiane sensor for cerium(III) ions.
    Shamsipur M; Yousefi M; Ganjali MR
    Anal Chem; 2000 Jun; 72(11):2391-4. PubMed ID: 10857610
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cesium ion-selective electrodes based on 1,3-alternate thiacalix[4]biscrown-6,6.
    Choi Y; Kim H; Lee JK; Lee SH; Lim HB; Kim JS
    Talanta; 2004 Nov; 64(4):975-80. PubMed ID: 18969699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of concentration of ion exchanger, plasticizer and molecular weight of cyanocopolymers on selectivity and sensitivity of Cd(II) ion selective electrode.
    Gupta KC; Jeanne D'Arc M
    Talanta; 2000 Sep; 52(6):1087-103. PubMed ID: 18968071
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ribonucleic acid as a novel ionophore for potentiometric membrane sensors of some transition metal ions.
    Hassan SS; Mahmoud WH; Othman AH
    Talanta; 1998 Oct; 47(2):377-85. PubMed ID: 18967339
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coated-wire copper(II)-selective electrode based on phenylglyoxal-alpha-monoxime ionophore.
    Firooz AR; Mazloum M; Safari J; Amini MK
    Anal Bioanal Chem; 2002 Mar; 372(5-6):718-22. PubMed ID: 11941444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples.
    Gupta VK; Singh AK; Gupta B
    Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor.
    Ganjali MR; Norouzi P; Alizadeh T; Adib M
    Anal Chim Acta; 2006 Aug; 576(2):275-82. PubMed ID: 17723643
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bis(2-hydroxyacetophenone)ethylenediimine as a neutral carrier in a coated-wire membrane electrode for lead(II).
    Mazloum Ardakani M; Pourhakak P; Salavati-Niasari M
    Anal Sci; 2006 Jun; 22(6):865-70. PubMed ID: 16772687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione.
    Kopylovich MN; Mahmudov KT; Pombeiro AJ
    J Hazard Mater; 2011 Feb; 186(2-3):1154-62. PubMed ID: 21177026
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.