These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 18967489)
1. Catalytic hydrogen evolution in the presence of methylthiohydantoin-glycine and cobalt(II) ion: a study by cathodic stripping voltammetry at a hanging mercury drop electrode. Bănică FG; Spătaru N Talanta; 1999 Feb; 48(2):491-4. PubMed ID: 18967489 [TBL] [Abstract][Full Text] [Related]
2. Catalytic hydrogen evolution in cathodic stripping voltammetry on a mercury electrode in the presence of cobalt(II) ion and phenylthiourea or thiourea. Spătaru N; Bănica FG Analyst; 2001 Nov; 126(11):1907-11. PubMed ID: 11763065 [TBL] [Abstract][Full Text] [Related]
3. Determination of cobalt in seawater by catalytic adsorptive cathodic stripping voltammetry. Vega M; van den Berg CM Anal Chem; 1997 Mar; 69(5):874-81. PubMed ID: 21639224 [TBL] [Abstract][Full Text] [Related]
4. Behavior and quantification studies of amiloride drug using cyclic and square-wave adsorptive stripping voltammetry at a mercury electrode. Hammam E J Pharm Biomed Anal; 2004 Mar; 34(5):1109-16. PubMed ID: 15019045 [TBL] [Abstract][Full Text] [Related]
5. Increased sensitivity of anodic stripping voltammetry at the hanging mercury drop electrode by ultracathodic deposition. Rodrigues JA; Rodrigues CM; Almeida PJ; Valente IM; Gonçalves LM; Compton RG; Barros AA Anal Chim Acta; 2011 Sep; 701(2):152-6. PubMed ID: 21801881 [TBL] [Abstract][Full Text] [Related]
6. Catalytic cathodic stripping voltammetry of oxidized glutathione at a hanging mercury drop electrode in the presence of nickel ion. Banica FG; Fogg AG; Moreira JC Talanta; 1995 Feb; 42(2):227-34. PubMed ID: 18966221 [TBL] [Abstract][Full Text] [Related]
7. Assay of the anti-psychotic drug haloperidol in bulk form, pharmaceutical formulation and biological fluids using square-wave adsorptive stripping voltammetry at a mercury electrode. El-Desoky HS; Ghoneim MM J Pharm Biomed Anal; 2005 Jul; 38(3):543-50. PubMed ID: 15925258 [TBL] [Abstract][Full Text] [Related]
9. Advantages of using a mercury coated, micro-wire, electrode in adsorptive cathodic stripping voltammetry. Gun J; Salaün P; van den Berg CM Anal Chim Acta; 2006 Jun; 571(1):86-92. PubMed ID: 17723424 [TBL] [Abstract][Full Text] [Related]
10. Electrochemical behavior of phytochelatins and related peptides at the hanging mercury drop electrode in the presence of cobalt(II) ions. Dorcák V; Sestáková I Bioelectrochemistry; 2006 Jan; 68(1):14-21. PubMed ID: 15936992 [TBL] [Abstract][Full Text] [Related]
11. Linear scan voltammetric indirect determination of Al(III) by the catalytic cathodic response of norepinephrine at the hanging mercury drop electrode. Zhang F; Ji M; Xu Q; Yang L; Bi S J Inorg Biochem; 2005 Sep; 99(9):1756-61. PubMed ID: 16039719 [TBL] [Abstract][Full Text] [Related]
12. Differential pulse cathodic stripping voltammetry of the copper complexes of glycyl-L-histidyl-glycine at a hanging mercury drop electrode. Ertas FN; Fogg AG; Moreira JC; Barek J Talanta; 1993 Oct; 40(10):1481-8. PubMed ID: 18965809 [TBL] [Abstract][Full Text] [Related]
13. Voltammetry on mercury and carbon electrodes as a tool for studies of metallothionein interactions with metal ions. Sestáková I; Mader P Cell Mol Biol (Noisy-le-grand); 2000 Mar; 46(2):257-67. PubMed ID: 10774918 [TBL] [Abstract][Full Text] [Related]
14. Catalytic-adsorptive stripping voltammetry of cobalt in the presence of 2,2'-bipyridine and nitrite. Gao Z; Siong Siow K Talanta; 1996 Feb; 43(2):255-61. PubMed ID: 18966486 [TBL] [Abstract][Full Text] [Related]
15. Redox kinetic measurements of glutathione at the mercury electrode by means of square-wave voltammetry. The role of copper, cadmium and zinc ions. Mladenov M; Mirceski V; Gjorgoski I; Jordanoski B Bioelectrochemistry; 2004 Dec; 65(1):69-76. PubMed ID: 15522695 [TBL] [Abstract][Full Text] [Related]
16. Cathodic adsorptive stripping voltammetric behaviour of guanine in the presence of copper at the static mercury drop electrode. Farias PA; Wagener Ade L; Bastos MB; Silva AT; Castro AA Talanta; 2003 Dec; 61(6):829-35. PubMed ID: 18969248 [TBL] [Abstract][Full Text] [Related]
17. Highly sensitive and selective measurements of cobalt by catalytic adsorptive cathodic stripping voltammetry. Safavi A; Shams E Talanta; 2000 May; 51(6):1117-23. PubMed ID: 18967943 [TBL] [Abstract][Full Text] [Related]
18. Determination of tryptophan and histidine by adsorptive cathodic stripping voltammetry using H-point standard addition method. Ensafi AA; Hajian R Anal Chim Acta; 2006 Nov; 580(2):236-43. PubMed ID: 17723779 [TBL] [Abstract][Full Text] [Related]
19. The versatility of salicylaldehyde thiosemicarbazone in the determination of copper in blood using adsorptive stripping voltammetry. Mahajan RK; Walia TP; Sumanjit ; Lobana TS Talanta; 2005 Oct; 67(4):755-9. PubMed ID: 18970236 [TBL] [Abstract][Full Text] [Related]
20. Cathodic adsorptive stripping voltammetry of drotaverine hydrochloride and its determination in tablets and human urine by differential pulse voltammetry. Zayed SI; Issa YM Bioelectrochemistry; 2009 Apr; 75(1):9-12. PubMed ID: 19138886 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]