These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Mass transfer in rectangular chromatographic channels. Poppe H J Chromatogr A; 2002 Mar; 948(1-2):3-17. PubMed ID: 12831178 [TBL] [Abstract][Full Text] [Related]
5. High efficiency hydrodynamic chromatography in micro- and sub-micrometer deep channels using an on-chip pressure-generation unit. Xia L; Dutta D Anal Chim Acta; 2017 Jan; 950():192-198. PubMed ID: 27916125 [TBL] [Abstract][Full Text] [Related]
6. Comparison of small size fully porous particles and superficially porous particles of chiral anion-exchange type stationary phases in ultra-high performance liquid chromatography: effect of particle and pore size on chromatographic efficiency and kinetic performance. Schmitt K; Woiwode U; Kohout M; Zhang T; Lindner W; Lämmerhofer M J Chromatogr A; 2018 Sep; 1569():149-159. PubMed ID: 30041874 [TBL] [Abstract][Full Text] [Related]
7. Pressure-Driven Chromatographic Separation Modes in Self-Enclosed Integrated Nanocapillaries. Duan L; Cao Z; Yobas L Anal Chem; 2016 Dec; 88(23):11601-11608. PubMed ID: 27800673 [TBL] [Abstract][Full Text] [Related]
8. High-speed gas chromatography using synchronized dual-valve injection. Gross GM; Prazen BJ; Grate JW; Synovec RE Anal Chem; 2004 Jul; 76(13):3517-24. PubMed ID: 15228319 [TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis and synthesis of the electrokinetic mass transport and adsorption mechanisms of a charged adsorbate in capillary electrochromatography systems employing charged adsorbent particles. Grimes BA; Liapis AI J Chromatogr A; 2001 Jun; 919(1):157-79. PubMed ID: 11459302 [TBL] [Abstract][Full Text] [Related]
10. Performance of a monolithic silica column in a capillary under pressure-driven and electrodriven conditions. Ishizuka N; Minakuchi H; Nakanishi K; Soga N; Nagayama H; Hosoya K; Tanaka N Anal Chem; 2000 Mar; 72(6):1275-80. PubMed ID: 10740870 [TBL] [Abstract][Full Text] [Related]
11. Preparation and chromatographic evaluation of a cysteine-bonded zwitterionic hydrophilic interaction liquid chromatography stationary phase. Shen A; Guo Z; Cai X; Xue X; Liang X J Chromatogr A; 2012 Mar; 1228():175-82. PubMed ID: 22099229 [TBL] [Abstract][Full Text] [Related]
12. Capillary ion chromatography of inorganic anions on octadecyl silica monolith modified with an amphoteric surfactant. O Ríordáin C; Gillespie E; Connolly D; Nesterenko PN; Paull B J Chromatogr A; 2007 Feb; 1142(2):185-93. PubMed ID: 17207491 [TBL] [Abstract][Full Text] [Related]
13. Effect of parallel segmented flow chromatography on the height equivalent to a theoretical plate III--influence of the column length, particle diameter, and the molecular weight of the analyte on the efficiency gain. Gritti F; Pynt J; Soliven A; Dennis GR; Shalliker RA; Guiochon G J Chromatogr A; 2014 Mar; 1333():32-44. PubMed ID: 24529404 [TBL] [Abstract][Full Text] [Related]
14. Valveless gated injection for microfluidic chip-based liquid chromatography system with polymer monolithic column. Wang XL; Zhu Y; Fang Q J Chromatogr A; 2012 Jul; 1246():123-8. PubMed ID: 22483268 [TBL] [Abstract][Full Text] [Related]
15. Development and assessment of a miniaturised centrifugal chromatograph for reversed-phase separations in micro-channels. Penrose A; Myers P; Bartle K; McCrossen S Analyst; 2004 Aug; 129(8):704-9. PubMed ID: 15284912 [TBL] [Abstract][Full Text] [Related]
16. Microchip reversed-phase liquid chromatography with packed column and electrochemical flow cell using polystyrene/poly(dimethylsiloxane). Ishida A; Natsume M; Kamidate T J Chromatogr A; 2008 Dec; 1213(2):209-17. PubMed ID: 18992887 [TBL] [Abstract][Full Text] [Related]
17. Novel general expressions that describe the behavior of the height equivalent of a theoretical plate in chromatographic systems involving electrically-driven and pressure-driven flows. Grimes BA; Lüdtke S; Unger KK; Liapis AI J Chromatogr A; 2002 Dec; 979(1-2):447-66. PubMed ID: 12498277 [TBL] [Abstract][Full Text] [Related]
18. A pressure-driven capillary electrophoretic system with injection valve sampling. Han C; Sun J; Liu J; Cheng H; Wang Y Analyst; 2015 Jan; 140(1):162-73. PubMed ID: 25373008 [TBL] [Abstract][Full Text] [Related]
19. Electrokinetic-driven microfluidic system in poly(dimethylsiloxane) for mass spectrometry detection integrating sample injection, capillary electrophoresis, and electrospray emitter on-chip. Thorslund S; Lindberg P; Andrén PE; Nikolajeff F; Bergquist J Electrophoresis; 2005 Dec; 26(24):4674-83. PubMed ID: 16273585 [TBL] [Abstract][Full Text] [Related]
20. Pressure-actuated microfluidic devices for electrophoretic separation of pre-term birth biomarkers. Sahore V; Kumar S; Rogers CI; Jensen JK; Sonker M; Woolley AT Anal Bioanal Chem; 2016 Jan; 408(2):599-607. PubMed ID: 26537925 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]