334 related articles for article (PubMed ID: 18968889)
1. A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone.
Mahajan RK; Kaur I; Lobana TS
Talanta; 2003 Jan; 59(1):101-5. PubMed ID: 18968889
[TBL] [Abstract][Full Text] [Related]
2. A mercury(II) selective sensor based on N,N'-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples.
Abu-Shawish HM
J Hazard Mater; 2009 Aug; 167(1-3):602-8. PubMed ID: 19195781
[TBL] [Abstract][Full Text] [Related]
3. Mercury(II) ion-selective electrodes based on p-tert-butyl calix[4]crowns with imine units.
Mahajan RK; Kaur R; Kaur I; Sharma V; Kumar M
Anal Sci; 2004 May; 20(5):811-4. PubMed ID: 15171285
[TBL] [Abstract][Full Text] [Related]
4. Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base.
Mashhadizadeh MH; Sheikhshoaie I
Talanta; 2003 May; 60(1):73-80. PubMed ID: 18969027
[TBL] [Abstract][Full Text] [Related]
5. A mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier.
Ye G; Chai Y; Yuan R; Dai J
Anal Sci; 2006 Apr; 22(4):579-82. PubMed ID: 16760602
[TBL] [Abstract][Full Text] [Related]
6. Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as neutral carrier.
Mashhadizadeh MH; Momeni A
Talanta; 2003 Jan; 59(1):47-53. PubMed ID: 18968883
[TBL] [Abstract][Full Text] [Related]
7. Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base.
Abbaspour A; Esmaeilbeig AR; Jarrahpour AA; Khajeh B; Kia R
Talanta; 2002 Aug; 58(2):397-403. PubMed ID: 18968765
[TBL] [Abstract][Full Text] [Related]
8. Organic-inorganic composite cation-exchanger: poly-o-toluidine Zr(IV) phosphate-based ion-selective membrane electrode for the potentiometric determination of mercury.
Khan AA; Inamuddin ; Akhtar T
Anal Sci; 2008 Jul; 24(7):881-7. PubMed ID: 18614830
[TBL] [Abstract][Full Text] [Related]
9. Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor.
Ganjali MR; Norouzi P; Alizadeh T; Adib M
Anal Chim Acta; 2006 Aug; 576(2):275-82. PubMed ID: 17723643
[TBL] [Abstract][Full Text] [Related]
10. Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor.
Ganjali MR; Mizani F; Emami M; Darjezini M; Darvich MR; Yousefi M
Anal Sci; 2004 Mar; 20(3):531-5. PubMed ID: 15068300
[TBL] [Abstract][Full Text] [Related]
11. Cadmium ion-selective electrode based on tetrathia-12-crown-4.
Shamsipur M; Mashhadizadeh MH
Talanta; 2001 Jan; 53(5):1065-71. PubMed ID: 18968198
[TBL] [Abstract][Full Text] [Related]
12. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione.
Kopylovich MN; Mahmudov KT; Pombeiro AJ
J Hazard Mater; 2011 Feb; 186(2-3):1154-62. PubMed ID: 21177026
[TBL] [Abstract][Full Text] [Related]
13. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
[TBL] [Abstract][Full Text] [Related]
14. Design and Characterization of Electrochemical Sensor for the Determination of Mercury(II) Ion in Real Samples Based upon a New Schiff Base Derivative as an Ionophore.
Alharthi SS; Fallatah AM; Al-Saidi HM
Sensors (Basel); 2021 Apr; 21(9):. PubMed ID: 33923078
[TBL] [Abstract][Full Text] [Related]
15. Cesium ion selective electrode based on calix[4]crown ether-ester.
Mahajan RK; Kumar M; Sharma Nee Bhalla V; Kaur I
Talanta; 2002 Sep; 58(3):445-50. PubMed ID: 18968770
[TBL] [Abstract][Full Text] [Related]
16. A highly selective thallium(I) electrode based on a thia substituted macrocyclic ionophore.
Singh AK; Saxena P
Talanta; 2005 May; 66(4):993-8. PubMed ID: 18970082
[TBL] [Abstract][Full Text] [Related]
17. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques.
Mazloum Ardakani M; Salavati-Niasari M; Khayat Kashani M; Ghoreishi SM
Anal Bioanal Chem; 2004 Mar; 378(6):1659-65. PubMed ID: 15214432
[TBL] [Abstract][Full Text] [Related]
18. Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometric monitoring of mercury ion(II).
Khani H; Rofouei MK; Arab P; Gupta VK; Vafaei Z
J Hazard Mater; 2010 Nov; 183(1-3):402-9. PubMed ID: 20692088
[TBL] [Abstract][Full Text] [Related]
19. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
Singh AK; Saxena P; Mehtab S; Gupta B
Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
[TBL] [Abstract][Full Text] [Related]
20. Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base.
Gholivand MB; Rahimi-Nasrabadi M; Ganjali MR; Salavati-Niasari M
Talanta; 2007 Sep; 73(3):553-60. PubMed ID: 19073070
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]