These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 18968896)

  • 1. DDB liver drug as a novel ionophore for potentiometric barium (II) membrane sensor.
    Hassan SS; Saleh MB; Abdel Gaber AA; Abdel Kream NA
    Talanta; 2003 Jan; 59(1):161-6. PubMed ID: 18968896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neutral bidentate organophosphorus compounds as novel ionophores for potentiometric membrane sensors for barium(II).
    Saleh MB
    Fresenius J Anal Chem; 2000 Jul; 367(6):530-4. PubMed ID: 11225826
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel potassium ion membrane sensor based on rifamycin neutral ionophore.
    Hassan SS; Mahmoud WH; Othman AH
    Talanta; 1997 Jun; 44(6):1087-94. PubMed ID: 18966840
    [TBL] [Abstract][Full Text] [Related]  

  • 4. PVC membrane sensor for potentiometric determination of iron (II) in some pharmaceutical formulations based on a new neutral ionophore.
    Abounassif MA; Al-Omar MA; Amr AG; Mostafa GA
    Drug Test Anal; 2011 Jun; 3(6):373-9. PubMed ID: 21698780
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A highly selective thallium(I) electrode based on a thia substituted macrocyclic ionophore.
    Singh AK; Saxena P
    Talanta; 2005 May; 66(4):993-8. PubMed ID: 18970082
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine.
    Gupta VK; Singh AK; Gupta B
    Anal Chim Acta; 2006 Aug; 575(2):198-204. PubMed ID: 17723591
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel uranyl membrane sensor with potentiometric anionic response.
    Hassan SS; Attawiya AM
    Talanta; 2006 Nov; 70(4):883-9. PubMed ID: 18970854
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sub-micro level monitoring of beryllium ions with a novel beryllium sensor based on 2,6-diphenyl-4-benzo-9-crown-3-pyridine.
    Ganjali MR; Rahimi-Nasrabadi M; Maddah B; Moghimi A; Faal-Rastegar M; Borhany S; Namazian M
    Talanta; 2004 Jul; 63(4):899-906. PubMed ID: 18969516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione.
    Kopylovich MN; Mahmudov KT; Pombeiro AJ
    J Hazard Mater; 2011 Feb; 186(2-3):1154-62. PubMed ID: 21177026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
    Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
    Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New potentiometric sensors based on selective recognition sites for determination of ephedrine in some pharmaceuticals and biological fluids.
    Hassan SS; Kamel AH; Abd El-Naby H
    Talanta; 2013 Jan; 103():330-6. PubMed ID: 23200395
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ribonucleic acid as a novel ionophore for potentiometric membrane sensors of some transition metal ions.
    Hassan SS; Mahmoud WH; Othman AH
    Talanta; 1998 Oct; 47(2):377-85. PubMed ID: 18967339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples.
    Singh AK; Mehtab S; Singh UP; Aggarwal V
    Anal Bioanal Chem; 2007 Aug; 388(8):1867-76. PubMed ID: 17622519
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ion selective electrode for cesium based on 5-(4'-nitrophenylazo)25,27-bis(2-propyloxy)26,28-dihydroxycalix[4]arene.
    Ramanjaneyulu PS; Singh P; Sayi YS; Chawla HM; Ramakumar KL
    J Hazard Mater; 2010 Mar; 175(1-3):1031-6. PubMed ID: 19942345
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new selectophore for gadolinium selective sensor.
    Zamani HA; Faridbod F; Ganjali MR
    Mater Sci Eng C Mater Biol Appl; 2014 Oct; 43():488-93. PubMed ID: 25175240
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel poly(vinyl chloride) matrix membrane sensor for batch and flow-injection determinations of thiocyanate, cyanide and some metal ions.
    Hassan SS; Badr IH; Kamel AH; Mohamed MS
    Anal Sci; 2009 Jul; 25(7):911-7. PubMed ID: 19609032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.
    Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form.
    Ragab MT; Abd El-Rahman MK; Ramadan NK; El-Ragehy NA; El-Zeany BA
    Talanta; 2015 Jun; 138():28-35. PubMed ID: 25863367
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
    Yaftian MR; Rayati S; Emadi D; Matt D
    Anal Sci; 2006 Aug; 22(8):1075-8. PubMed ID: 16896245
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin.
    Mostafa GAE; Ali EA; Alsalahi RA; Alrabiah H
    Molecules; 2023 Jun; 28(13):. PubMed ID: 37446807
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.