These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 18968960)

  • 1. On-line preconcentration and determination of cobalt by chelating microcolumns and flow injection atomic spectrometry.
    Haji Shabani AM; Dadfarnia S; Dehghan K
    Talanta; 2003 Mar; 59(4):719-25. PubMed ID: 18968960
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Speciation and determination of thallium by on-line microcolumn separation/preconcentration by flow injection-flame atomic absorption spectrometry using immobilized oxine as sorbent.
    Dadfarnia S; Assadollahi T; Haji Shabani AM
    J Hazard Mater; 2007 Sep; 148(1-2):446-52. PubMed ID: 17418486
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On-line preconcentration and determination of cobalt by DPTH-gel chelating microcolumn and flow injection inductively coupled plasma atomic emission spectrometry.
    Zougagh M; Rudner PC; de Torres AG; Cano Pavón JM
    Anal Bioanal Chem; 2004 Jan; 378(2):423-8. PubMed ID: 14513193
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Trace enrichment and determination of silver by immobilized DDTC microcolumn and flow injection atomic absorption spectrometry.
    Dadfarnia S; Haji Shabani AM; Gohari M
    Talanta; 2004 Oct; 64(3):682-7. PubMed ID: 18969659
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A flow injection on-line unequal flow complexation preconcentration procedure coupled with flame atomic absorption spectrometry for determination of lead in tap water].
    Wang ZY; Su YD; Li S; Gan LH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Nov; 28(11):2695-8. PubMed ID: 19271520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Extractive chromatograph on-line preconcentration flow injection flame atomic absorption spectrometric determination of trace silver in geological samples].
    Yuan Y; Guo X
    Guang Pu Xue Yu Guang Pu Fen Xi; 1998 Oct; 18(5):593-6. PubMed ID: 15825375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cloud point extraction for cobalt preconcentration with on-line phase separation in a knotted reactor followed by ETAAS determination in drinking waters.
    Gil RA; Gásquez JA; Olsina R; Martinez LD; Cerutti S
    Talanta; 2008 Jul; 76(3):669-73. PubMed ID: 18585337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of gold by nanometer titanium dioxide immobilized on silica gel packed microcolumn and flame atomic absorption spectrometry in geological and water samples.
    Liu R; Liang P
    Anal Chim Acta; 2007 Dec; 604(2):114-8. PubMed ID: 17996531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Solidified floating organic drop microextraction (SFODME) for simultaneous separation/preconcentration and determination of cobalt and nickel by graphite furnace atomic absorption spectrometry (GFAAS).
    Bidabadi MS; Dadfarnia S; Shabani AM
    J Hazard Mater; 2009 Jul; 166(1):291-6. PubMed ID: 19117672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel slurry sampling analysis of lead in different water samples by electrothermal atomic absorption spectrometry after coprecipitated with cobalt/pyrrolidine dithiocarbamate complex.
    Baysal A; Akman S; Calisir F
    J Hazard Mater; 2008 Oct; 158(2-3):454-9. PubMed ID: 18346848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Separation/preconcentration and determination of cadmium ions by solidification of floating organic drop microextraction and FI-AAS.
    Dadfarnia S; Shabani AM; Kamranzadeh E
    Talanta; 2009 Sep; 79(4):1061-5. PubMed ID: 19615509
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Trace level determination of cadmium in wine by on-line preconcentration in a 5-Br-PADAP functionalized wool-packed microcolumn coupled to flame atomic absorption spectrometry.
    Monasterio RP; Wuilloud RG
    Talanta; 2009 Oct; 79(5):1484-8. PubMed ID: 19635388
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation and preconcentration of cadmium ions using octadecyl silica membrane disks modified by methyltrioctylammonium chloride.
    Haji Shabani AM; Dadfarnia S; Motavaselian F; Ahmadi SH
    J Hazard Mater; 2009 Feb; 162(1):373-7. PubMed ID: 18583038
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples.
    Anthemidis AN; Ioannou KI
    Talanta; 2009 Jun; 79(1):86-91. PubMed ID: 19376348
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a new sequential injection in-line cloud point extraction system for flame atomic absorption spectrometric determination of manganese in food samples.
    Lemos VA; Baliza PX; de Carvalho AL; Oliveira RV; Teixeira LS; Bezerra MA
    Talanta; 2008 Oct; 77(1):388-93. PubMed ID: 18804650
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel separation/preconcentration system based on solidification of floating organic drop microextraction for determination of lead by graphite furnace atomic absorption spectrometry.
    Dadfarnia S; Salmanzadeh AM; Shabani AM
    Anal Chim Acta; 2008 Aug; 623(2):163-7. PubMed ID: 18620920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lead preconcentration onto C-18 minicolumn in continuous flow and its determination in biological and vegetable samples by flame atomic absorption spectrometry.
    Lima R; Leandro KC; Santelli RE
    Talanta; 1996 Jun; 43(6):977-83. PubMed ID: 18966570
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On-line ionic liquid-based preconcentration system coupled to flame atomic absorption spectrometry for trace cadmium determination in plastic food packaging materials.
    Martinis EM; Olsina RA; Altamirano JC; Wuilloud RG
    Talanta; 2009 May; 78(3):857-62. PubMed ID: 19269441
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of trace metals in urine with an on-line ultrasound-assisted digestion system combined with a flow-injection preconcentration manifold coupled to flame atomic absorption spectrometry.
    Cespón-Romero RM; Yebra-Biurrun MC
    Anal Chim Acta; 2008 Feb; 609(2):184-91. PubMed ID: 18261513
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow injection on-line displacement/solid phase extraction system coupled with flame atomic absorption spectrometry for selective trace silver determination in water samples.
    Christou CK; Anthemidis AN
    Talanta; 2009 Apr; 78(1):144-9. PubMed ID: 19174217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.