These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 18969707)

  • 1. FI automatic method for the determination of copper(II) based on coproporphyrin I-Cu(II)/TCPO/H(2)O(2) chemiluminescence reaction for the screening of waters.
    Meseguer-Lloret S; Campíns-Falcó P; Cárdenas S; Gallego M; Valcárcel M
    Talanta; 2004 Nov; 64(4):1030-5. PubMed ID: 18969707
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of copper(II) based on its catalytic effect on thiosemicarbazide-H(2)O(2)-CTMAB chemiluminescence reaction.
    Sorouraddin MH; Manzoori JL; Iranifam M
    Talanta; 2005 Jun; 66(5):1117-21. PubMed ID: 18970098
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Chemiluminescence determination of carbofuran at trace levels in lettuce and waters by flow-injection analysis.
    Huertas-Pérez JF; Gámiz-Gracia L; García-Campaña AM; González-Casado A; Martínez Vidal JL
    Talanta; 2005 Feb; 65(4):980-5. PubMed ID: 18969898
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel flow injection chemiluminescence determination of Cr(VI) with Dichlorotris(1,10-phenanthroline)ruthenium(II).
    Luaces MD; Martínez NC; Granda M; Valdés AC; Pérez-Conde C; Gutiérrez AM
    Talanta; 2011 Sep; 85(4):1904-8. PubMed ID: 21872036
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration.
    Li B; Wang D; Lv J; Zhang Z
    Talanta; 2006 Mar; 69(1):160-5. PubMed ID: 18970548
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The determination of glutamine with flow-injection chemiluminescence detection and mechanism study.
    Liu YM; Liu ZL; Shi YM; Tian W
    Luminescence; 2010; 25(1):50-4. PubMed ID: 19630088
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automatic chemiluminescence-based determination of carbaryl in various types of matrices.
    Pulgarín JA; Molina AA; López PF
    Talanta; 2006 Jan; 68(3):586-93. PubMed ID: 18970361
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Gas-diffusion flow injection determination of Hg(II) with chemiluminescence detection.
    Amini N; Kolev SD
    Anal Chim Acta; 2007 Jan; 582(1):103-8. PubMed ID: 17386481
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sequential injection anodic stripping voltammetry with monosegmented flow and in-line UV digestion for determination of Zn(II), Cd(II), Pb(II) and Cu(II) in water samples.
    Siriangkhawut W; Grudpan K; Jakmunee J
    Talanta; 2011 Jun; 84(5):1366-73. PubMed ID: 21641453
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous determination of Cu(II), Ni(II) and Zn(II) by peroxyoxalate chemiluminescence using Partial Least Squares calibration.
    Murillo Pulgarin JA; García Bermejo LF; Carrasquero A
    Analyst; 2011 Jan; 136(2):304-8. PubMed ID: 21042635
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of water sample storage protocols in chemiluminescence detection of trace elements.
    Moliner-Martínez Y; Meseguer-Lloret S; Tortajada-Genaro LA; Campíns-Falcó P
    Talanta; 2003 Jun; 60(2-3):257-68. PubMed ID: 18969048
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel oxidation reaction of prochlorperazine with bromate in the presence of synergistic activators and its application to trace determination by flow injection/spectrophotometric method.
    Uraisin K; Takayanagi T; Nacapricha D; Motomizu S
    Anal Chim Acta; 2006 Oct; 580(1):68-74. PubMed ID: 17723757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preconcentration of Cu(II), Fe(III) and Pb(II) with 2-((2-aminoethylamino)methyl)phenol-functionalized activated carbon followed by ICP-OES determination.
    He Q; Hu Z; Jiang Y; Chang X; Tu Z; Zhang L
    J Hazard Mater; 2010 Mar; 175(1-3):710-4. PubMed ID: 19926213
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potentiometric flow injection determination of manganese(II) by using a hexacyanoferrate(III)-hexacyanoferrate(II) potential buffer.
    Ohura H; Ishibashi Y; Imato T; Yamasaki S
    Talanta; 2003 May; 60(1):177-84. PubMed ID: 18969038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spectrophotometric flow-injection analysis of mercury(II) in pharmaceuticals with p-nitrobenzoxosulfamate.
    Andac M; Asan A; Bekdemir Y; Kutuk H; Isildak I
    Talanta; 2003 May; 60(1):191-7. PubMed ID: 18969040
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Potentiometric flow-injection determination of trace hydrogen peroxide based on its induced reaction in iron(III)-iron(II) potential buffer containing bromide and molybdenum(VI).
    Ohura H; Imato T; Yamasaki S; Ishibashi N
    Talanta; 1996 Jun; 43(6):943-50. PubMed ID: 18966565
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A flow injection chemiluminescence method for the determination of lincomycin in serum using a diperiodato-cuprate (III)-luminol system.
    Hu Y; Li G; Zhang Z
    Luminescence; 2011; 26(5):313-8. PubMed ID: 22021244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of tetracycline, chlortetracycline and oxytetracycline by flow injection with inhibitory chemiluminescence detection using copper(II) as a probe ion.
    Han S; Liu E; Li H
    Luminescence; 2006; 21(2):106-11. PubMed ID: 16416504
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The determination of hydrogen peroxide generated from cigarette smoke with an ultrasensitive and highly selective chemiluminescence method.
    Hu Y; Zhang Z; Yang C
    Anal Chim Acta; 2007 Oct; 601(1):95-100. PubMed ID: 17904474
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel chemiluminescence method for the determination of ergometrine maleate in serum sample without chemiluminescence reagent.
    Hu Y; Zhang Z; Li G
    Talanta; 2010 Apr; 81(1-2):499-504. PubMed ID: 20188953
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.